| Literature DB >> 28870163 |
Sibel Oba1, Hacer Sebnem Turk1, Canan Tulay Isil2, Huseyin Erdogan1, Pinar Sayin1, Ali Ihsan Dokucu3.
Abstract
BACKGROUND: The Supreme™ and ProSeal™ laryngeal mask airways (LMAs) are widely used in paediatric anaesthesia; however, LMA use in infants is limited because many anaesthesiologists prefer to use tracheal intubation in infants. In this study, we compared the Supreme and ProSeal LMAs in infants by measuring their performance characteristics, including insertion features, ventilation parameters, induced changes in haemodynamics and rates of postoperative complications.Entities:
Keywords: Infants; Laryngeal mask airway ProSeal; Laryngeal mask airway Supreme
Mesh:
Year: 2017 PMID: 28870163 PMCID: PMC5584514 DOI: 10.1186/s12871-017-0418-z
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Fig. 1CONSORT flow diagram
Patient demographics
| Group P ( | Group S ( | ||
|---|---|---|---|
| Age (months) mean ± SD | 5.7 ± 3,2 | 5.9 ± 3,0 | |
| Gender (F/M) n (%) | 14 (23.3)/46 (76.7) | 18 (30.0)/42 (70.0) | |
| Weight (kg) mean ± SD | 7,3 ± 2,0 (7) | 7,7 ± 2,2 (7) | |
| LMA Size 1 | n (%) | 20 (33.3) | 18 (30) |
| 1.5 | n (%) | 40 (66.7) | 42 (70) |
F female, M male, SD standard deviation
Surgical characteristics
| Group P ( | Group S ( |
| |
|---|---|---|---|
| Mean ± SD | Mean ± SD | ||
| Anaesthesia Time (min) | 49.1 ± 18,3 | 48.6 ± 14,1 | 0.696 |
| Surgical Time (min) | 37.8 ± 15,5 | 39.1 ± 14,2 | 0.359 |
| LMA Duration (min) | 44.8 ± 18,0 | 44.0 ± 14,3 | 0.729 |
| Recovery Time (min) | 7.3 ± 2,0 | 7.6 ± 2,2 | 0.274 |
Min minutes, LMA laryngeal mask airway; P < 0.05 is statistically significant
Laryngeal Mask Airway (LMA) insertion characteristics
| Group P ( | Group S ( |
| ||
|---|---|---|---|---|
| LMA Insertion Time (sec) mean ± SD | 8.1 ± 2,9 | 8.8 ± 2,0 | 0.002 | |
| Number of Manipulations Required to Insert LMA n (%) | 1 | 51 (85.0) | 47 (78.3) | 0.345 |
| 2 | 9 (15.0) | 13 (21.7) | ||
| Ease of LMA Insertion n (%)a | 1 | 51 (85.0) | 46 (76.7) | 0.246 |
| 2 | 9 (15.0) | 14 (23.3) | ||
| 3 | 0 | 0 | ||
LMA laryngeal mask airway, SD standard deviation, sec seconds; P < 0.05 is statistically significant; aease of LMA insertion was graded as 1: no resistance (easy), 2: moderate resistance (difficult) or 3: inability (impossible) to place the LMA
Haemodynamic variables
| Group P ( | Group S ( |
| |
|---|---|---|---|
| Mean ± SD | Mean ± SD | ||
| HR Beginning | 143.4 ± 9.8 | 144.9 ± 6.4 | 0.309 |
| HR after LMA Insertion | 140.3 ± 11.5 | 140.9 ± 8.4 | 0.779 |
| HR before Extubation | 130.6 ± 9.8 | 135.4 ± 6.6 | 0.011 |
| HR after Extubation | 135.4 ± 8.3 | 138.9 ± 5.7 | 0.042 |
| SpO2 Beginning | 99.9 ± 0.3 | 100.0 ± 0.2 | 0.698 |
| SpO2 after LMA Insertion | 99.3 ± 1.4 | 99.1 ± 1.2 | 0.262 |
| SpO2 before Extubation | 99.6 ± 0.7 | 99.4 ± 0.9 | 0.126 |
| SpO2 after Extubation | 99.6 ± 0.8 | 99.6 ± 0.6 | 0.243 |
| EtCO2 Beginning | 32.1 ± 1.8 | 32.3 ± 1.8 | 0.603 |
| EtCO2 before Extubation | 32.3 ± 1.8 | 32.3 ± 1.8 | 0.879 |
HR heart rate, LMA laryngeal mask airway, SpO oxygen saturation, EtCO end tidal carbon dioxide value; P < 0.05 is statistically significant
Mean ventilation parametersa
| Group P ( | Group S ( |
| |
|---|---|---|---|
| Mean ± SD | Mean ± SD | ||
| Peak Pressure (cm H2O) | 18.1 ± 3.2 | 20.1 ± 2.9 |
|
| Mean Pressure (cm H2O) | 7.3 ± 1.2 | 7.8 ± 1.1 |
|
| Leakage Percentage (%) | 6.4 ± 1.3 | 7.3 ± 1.0 |
|
| Leakage Pressure (cm H2O) | 33.0 ± 2.2 | 31.5 ± 1.8 |
|
SD standard deviation; P < 0.05 is statistically significant; athese parameters were measured three times: the first, after LMA insertion; the second, 10 min after LMA insertion; and the third, before extubation. The means ± SD were statistically analysed
Mucosal damage and complications
| Group P ( | Group S ( |
| |
|---|---|---|---|
| n (%) | n (%) | ||
| Mucosal Hyperaemia | 3 (5.0) | 5 (8.3) | 0.717 |
| Mucosal Damage | 3 (5.0) | 5 (8.3) | 0.717 |
| Blood on LMA | 3 (5.0) | 5 (8.3) | 0.717 |
| Complications | 5 (8.3) | 4 (6.7) | 1.000 |
| Cough | 3 (5.0) | 3 (5.0) | |
| Bronchospasm | 1 (1.7) | 0 (0.0) | |
| Bloating | 1 (1.7) | 1 (1.7) |
LMA laryngeal mask airway; P < 0.05 is statistically significant