Literature DB >> 28866486

Estimation of Basis Line-Integrals in a Spectral Distortion-Modeled Photon Counting Detector Using Low-Rank Approximation-Based X-Ray Transmittance Modeling: K-Edge Imaging Application.

Okkyun Lee, Steffen Kappler, Christoph Polster, Katsuyuki Taguchi.   

Abstract

Photon counting detectors (PCDs) provide multiple energy-dependent measurements for estimating basis line-integrals. However, the measured spectrum is distorted from the spectral response effect (SRE) via charge sharing, K-fluorescence emission, and so on. Thus, in order to avoid bias and artifacts in images, the SRE needs to be compensated. For this purpose, we recently developed a computationally efficient three-step algorithm for PCD-CT without contrast agents by approximating smooth X-ray transmittance using low-order polynomial bases. It compensated the SRE by incorporating the SRE model in a linearized estimation process and achieved nearly the minimum variance and unbiased (MVU) estimator. In this paper, we extend the three-step algorithm to K-edge imaging applications by designing optimal bases using a low-rank approximation to model X-ray transmittances with arbitrary shapes (i.e., smooth without the K-edge or discontinuous with the K-edge). The bases can be used to approximate the X-ray transmittance and to linearize the PCD measurement modeling and then the three-step estimator can be derived as in the previous approach: estimating the x-ray transmittance in the first step, estimating basis line-integrals including that of the contrast agent in the second step, and correcting for a bias in the third step. We demonstrate that the proposed method is more accurate and stable than the low-order polynomial-based approaches with extensive simulation studies using gadolinium for the K-edge imaging application. We also demonstrate that the proposed method achieves nearly MVU estimator, and is more stable than the conventional maximum likelihood estimator in high attenuation cases with fewer photon counts.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28866486     DOI: 10.1109/TMI.2017.2746269

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Assessment of Multienergy Interpixel Coincidence Counters (MEICC) for Charge Sharing Correction or Compensation for Photon Counting Detectors With Boxcar Signals.

Authors:  Katsuyuki Taguchi
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-06-17

2.  Experimental study of photon-counting CT neural network material decomposition under conditions of pulse pileup.

Authors:  Parker J B Jenkins; Taly Gilat Schmidt
Journal:  J Med Imaging (Bellingham)       Date:  2021-01-09

3.  Model-based pulse pileup and charge sharing compensation for photon counting detectors: A simulation study.

Authors:  Katsuyuki Taguchi; Christoph Polster; W Paul Segars; Nafi Aygun; Karl Stierstorfer
Journal:  Med Phys       Date:  2022-07-04       Impact factor: 4.506

  3 in total