Literature DB >> 28858894

Multiple Sclerosis: Improved Detection of Active Cerebral Lesions With 3-Dimensional T1 Black-Blood Magnetic Resonance Imaging Compared With Conventional 3-Dimensional T1 GRE Imaging.

Nora N Sommer, Tobias Saam, Eva Coppenrath, Hendrik Kooijman, Tania Kümpfel, Maximilian Patzig, Sebastian E Beyer, Wieland H Sommer, Maximilian F Reiser, Birgit Ertl-Wagner, Karla M Treitl.   

Abstract

OBJECTIVES: The aim of this study was to assess the diagnostic accuracy of a modified high-resolution whole-brain three-dimensional T1-weighted black-blood sequence (T1-weighted modified volumetric isotropic turbo spin echo acquisition [T1-mVISTA]) in comparison to a standard three-dimensional T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) sequence for detection of contrast-enhancing cerebral lesions in patients with relapsing-remitting multiple sclerosis (MS).
MATERIALS AND METHODS: After institutional review board approval and informed consent, 22 patients (8 men; aged 31.0 ± 9.2 years) with relapsing-remitting MS were included in this monocentric prospective cohort study.Contrast-enhanced T1-mVISTA and MP-RAGE, both with 0.8 mm resolution, were performed in all patients. In a substudy of 12 patients, T1-mVISTA was compared with a T1-mVISTA with 1.0 mm resolution (T1-mVISTA_1.0). Reference lesions were defined by an experienced neuroradiologist using all available sequences and served as the criterion standard. T1-mVISTA, T1-mVISTA_1.0, and MP-RAGE sequences were read in random order 4 weeks apart. Image quality, visual contrast enhancement, contrast-to-noise-ratio (CNR), diagnostic confidence, and lesion size were assessed and compared by Wilcoxon and Mann-Whitney U tests.
RESULTS: Eleven of 22 patients displayed contrast-enhancing lesions. Visual contrast enhancement, CNR, and diagnostic confidence of contrast-enhancing MS lesions were significantly increased in T1-mVISTA compared with MP-RAGE (P < 0.001). Significantly more contrast-enhancing lesions were detected with T1-mVISTA than with MP-RAGE (71 vs 39, respectively; P < 0.001). With MP-RAGE, 25.6% of lesions were missed in the initial reading, whereas only 4.2% of lesions were missed with T1-mVISTA. Increase of the voxel volume from 0.8 mm to 1.0 mm isotropic in T1-mVISTA_1.0 did not affect the detectability of lesions, whereas scan time was decreased from 4:43 to 1:55 minutes.
CONCLUSIONS: Three-dimensional T1-mVISTA improves the detection rates of contrast-enhancing cerebral MS lesions compared with conventional 3D MP-RAGE sequences by increasing CNR of lesions and might, therefore, be useful in patient management.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 28858894     DOI: 10.1097/RLI.0000000000000410

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

1.  Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques.

Authors:  L Danieli; G C Riccitelli; D Distefano; E Prodi; E Ventura; A Cianfoni; A Kaelin-Lang; M Reinert; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-20       Impact factor: 3.825

2.  Multiple sclerosis lesion segmentation from brain MRI using U-Net based on wavelet pooling.

Authors:  Ali Alijamaat; Alireza NikravanShalmani; Peyman Bayat
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-04-29       Impact factor: 2.924

3.  Contrast-enhanced modified 3D T1-weighted TSE black-blood imaging can improve detection of infectious and neoplastic meningitis.

Authors:  Nora Navina Sommer; Romina Pons Lucas; Eva Coppenrath; Hendrik Kooijman; Franziska Galiè; Nina Hesse; Wieland H Sommer; Karla M Treitl; Tobias Saam; Matthias F Froelich
Journal:  Eur Radiol       Date:  2019-11-05       Impact factor: 5.315

4.  Brain oxygen extraction fraction mapping in patients with multiple sclerosis.

Authors:  Junghun Cho; Thanh D Nguyen; Weiyuan Huang; Elizabeth M Sweeney; Xianfu Luo; Ilhami Kovanlikaya; Shun Zhang; Kelly M Gillen; Pascal Spincemaille; Ajay Gupta; Susan A Gauthier; Yi Wang
Journal:  J Cereb Blood Flow Metab       Date:  2021-09-24       Impact factor: 6.960

5.  Nonlesional Sources of Contrast Enhancement on Postgadolinium "Black-Blood" 3D T1-SPACE Images in Patients with Multiple Sclerosis.

Authors:  L Danieli; L Roccatagliata; D Distefano; E Prodi; G C Riccitelli; A Diociasi; L Carmisciano; A Cianfoni; T Bartalena; A Kaelin-Lang; C Gobbi; C Zecca; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2022-05-26       Impact factor: 4.966

6.  Improved Lesion Conspicuity with Contrast-Enhanced 3D T1 TSE Black-Blood Imaging in Cranial Neuritis: A Comparative Study of Contrast-Enhanced 3D T1 TSE, 3D T1 Fast-Spoiled Gradient Echo, and 3D T2 FLAIR.

Authors:  T-W Baek; Y Kang; H-J Lee
Journal:  AJNR Am J Neuroradiol       Date:  2021-03-11       Impact factor: 3.825

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.