Literature DB >> 28825865

The physiological strain incurred during electrical utilities work over consecutive work shifts in hot environments: A case report.

Robert D Meade1, Andrew W D'Souza1, Lovely Krishen2, Glen P Kenny1.   

Abstract

PURPOSE: In this article, we evaluated physiological strain in electrical utilities workers during consecutive work shifts in hot outdoor conditions.
METHODS: Four highly experienced electrical utilities workers were monitored during regularly scheduled work performed in hot conditions (∼34°C) on two consecutive days. Worker hydration (urine specific gravity) was assessed prior to and following work. The level of physical exertion was determined by video analysis. Body core temperature (Tcore) and heart rate (HR; presented as a percentage of maximum, %HRmax) were monitored continuously. Responses were reported for each worker individually and as a group mean ± standard deviation.
RESULTS: According to current guidelines, all workers were dehydrated prior to work on both days (urine specific gravity: day 1, 1.025 ± 0.005; day 2, 1.029 ± 0.004) and remained dehydrated following work (urine specific gravity: day 1, 1.027 ± 0.015; day 2, 1.032 ± 0.004) except for one worker on day 1 (urine specific gravity of 1.005). On day 1, the proportion of the work shift spent at rest (as defined by the American Conference for Governmental and Industrial Hygienists, ACGIH) was 51 ± 15% (range: 30-64%). Time spent resting increased in all workers on the second day reaching 66 ± 5% (range: 60-71%) of the work shift. Work shift average Tcore was 37.6 ± 0.1°C (range: 37.5-37.7°C) and 37.7 ± 0.2°C (range: 37.5-37.9°C) on days 1 and 2, respectively. Peak Tcore surpassed the ACGIH recommended threshold limit of 38.0°C for work in the heat in three workers on day 1 (38.1 ± 0.2°C, range: 37.8-38.2°C) while all workers exceeded this threshold on day 2 (38.4 ± 0.2°C, range: 38.2-38.7°C). By contrast, work shift average (day 1, 67 ± 7%HRmax, range: 59-74%HRmax; day 2, 65 ± 4%HRmax, range: 60-70%HRmax) and peak (day 1, 90 ± 6%HRmax, range: 83-98%HRmax; day 2, 87 ± 10%HRmax, range: 73-97%HRmax) HR were similar between days.
CONCLUSION: This case report demonstrates elevations in thermal strain over consecutive work shifts despite decreases in work effort in electrical utilities workers during regular work in the heat.

Keywords:  Climate change; heat exposure; heat waves; occupational heat stress; workers

Mesh:

Year:  2017        PMID: 28825865     DOI: 10.1080/15459624.2017.1365151

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  4 in total

Review 1.  Occupational heat strain in outdoor workers: A comprehensive review and meta-analysis.

Authors:  Leonidas G Ioannou; Josh Foster; Nathan B Morris; Jacob F Piil; George Havenith; Igor B Mekjavic; Glen P Kenny; Lars Nybo; Andreas D Flouris
Journal:  Temperature (Austin)       Date:  2022-04-26

2.  Heat Strain Evaluation of Power Grid Outdoor Workers Based on a Human Bioheat Model.

Authors:  Letian Li; Boyang Sun; Zhuqiang Hu; Jun Zhang; Song Gao; Haifeng Bian; Jiansong Wu
Journal:  Int J Environ Res Public Health       Date:  2022-06-26       Impact factor: 4.614

3.  Indicators to assess physiological heat strain - Part 3: Multi-country field evaluation and consensus recommendations.

Authors:  Leonidas G Ioannou; Lydia Tsoutsoubi; Konstantinos Mantzios; Maria Vliora; Eleni Nintou; Jacob F Piil; Sean R Notley; Petros C Dinas; George A Gourzoulidis; George Havenith; Matt Brearley; Igor B Mekjavic; Glen P Kenny; Lars Nybo; Andreas D Flouris
Journal:  Temperature (Austin)       Date:  2022-04-01

Review 4.  Fundamental Concepts of Human Thermoregulation and Adaptation to Heat: A Review in the Context of Global Warming.

Authors:  Chin Leong Lim
Journal:  Int J Environ Res Public Health       Date:  2020-10-24       Impact factor: 3.390

  4 in total