Literature DB >> 28815270

Pre-analytic evaluation of volumetric absorptive microsampling and integration in a mass spectrometry-based metabolomics workflow.

Chiara Volani1,2, Giulia Caprioli1, Giovanni Calderisi1, Baldur B Sigurdsson1, Johannes Rainer1, Ivo Gentilini3, Andrew A Hicks1, Peter P Pramstaller1, Guenter Weiss2, Sigurdur V Smarason1, Giuseppe Paglia4.   

Abstract

Volumetric absorptive microsampling (VAMS) is a novel approach that allows single-drop (10 μL) blood collection. Integration of VAMS with mass spectrometry (MS)-based untargeted metabolomics is an attractive solution for both human and animal studies. However, to boost the use of VAMS in metabolomics, key pre-analytical questions need to be addressed. Therefore, in this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. We first evaluated the best extraction procedure for the polar metabolome and found that the highest number and amount of metabolites were recovered upon extraction with acetonitrile/water (70:30). In contrast, basic conditions (pH 9) resulted in divergent metabolite profiles mainly resulting from the extraction of intracellular metabolites originating from red blood cells. In addition, the prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but once the VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months. The time used for drying the sample did also affect the metabolome. In fact, some metabolites were rapidly degraded or accumulated in the sample during the first 48 h at room temperature, indicating that a longer drying step will significantly change the concentration in the sample. Graphical abstract Volumetric absorptive microsampling (VAMS) is a novel technology that allows single-drop blood collection and, in combination with mass spectrometry (MS)-based untargeted metabolomics, represents an attractive solution for both human and animal studies. In this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. The latter revealed that prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but if VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months.

Entities:  

Keywords:  Mass spectrometry; Metabolomics; Volumetric absorptive microsampling

Mesh:

Year:  2017        PMID: 28815270      PMCID: PMC5694668          DOI: 10.1007/s00216-017-0571-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  40 in total

1.  Quantification of glutamine in dried blood spots and plasma by tandem mass spectrometry for the biochemical diagnosis and monitoring of ornithine transcarbamylase deficiency.

Authors:  Minh-Uyen Trinh; Jennifer Blake; J Rodney Harrison; Rosemarie Gerace; Enzo Ranieri; Janice M Fletcher; David W Johnson
Journal:  Clin Chem       Date:  2003-04       Impact factor: 8.327

2.  Metabolite profiles from dried biofluid spots for metabonomic studies using UPLC combined with oaToF-MS.

Authors:  Filippos Michopoulos; Georgios Theodoridis; Christopher J Smith; Ian D Wilson
Journal:  J Proteome Res       Date:  2010-06-04       Impact factor: 4.466

3.  Global metabolic profiling procedures for urine using UPLC-MS.

Authors:  Elizabeth J Want; Ian D Wilson; Helen Gika; Georgios Theodoridis; Robert S Plumb; John Shockcor; Elaine Holmes; Jeremy K Nicholson
Journal:  Nat Protoc       Date:  2010-06       Impact factor: 13.491

4.  Stabilizing drug molecules in biological samples.

Authors:  Jiwen Chen; Yunsheng Hsieh
Journal:  Ther Drug Monit       Date:  2005-10       Impact factor: 3.681

Review 5.  A review of blood sample handling and pre-processing for metabolomics studies.

Authors:  Vinicius Veri Hernandes; Coral Barbas; Danuta Dudzik
Journal:  Electrophoresis       Date:  2017-06-08       Impact factor: 3.535

6.  Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis.

Authors:  Philip Denniff; Neil Spooner
Journal:  Anal Chem       Date:  2014-08-06       Impact factor: 6.986

7.  Biomarkers defining the metabolic age of red blood cells during cold storage.

Authors:  Giuseppe Paglia; Angelo D'Alessandro; Óttar Rolfsson; Ólafur E Sigurjónsson; Aarash Bordbar; Sirus Palsson; Travis Nemkov; Kirk C Hansen; Sveinn Gudmundsson; Bernhard O Palsson
Journal:  Blood       Date:  2016-08-23       Impact factor: 22.113

8.  Liquid chromatography quadrupole time-of-flight mass spectrometry characterization of metabolites guided by the METLIN database.

Authors:  Zheng-Jiang Zhu; Andrew W Schultz; Junhua Wang; Caroline H Johnson; Steven M Yannone; Gary J Patti; Gary Siuzdak
Journal:  Nat Protoc       Date:  2013-02-07       Impact factor: 13.491

9.  A cross-platform toolkit for mass spectrometry and proteomics.

Authors:  Matthew C Chambers; Brendan Maclean; Robert Burke; Dario Amodei; Daniel L Ruderman; Steffen Neumann; Laurent Gatto; Bernd Fischer; Brian Pratt; Jarrett Egertson; Katherine Hoff; Darren Kessner; Natalie Tasman; Nicholas Shulman; Barbara Frewen; Tahmina A Baker; Mi-Youn Brusniak; Christopher Paulse; David Creasy; Lisa Flashner; Kian Kani; Chris Moulding; Sean L Seymour; Lydia M Nuwaysir; Brent Lefebvre; Frank Kuhlmann; Joe Roark; Paape Rainer; Suckau Detlev; Tina Hemenway; Andreas Huhmer; James Langridge; Brian Connolly; Trey Chadick; Krisztina Holly; Josh Eckels; Eric W Deutsch; Robert L Moritz; Jonathan E Katz; David B Agus; Michael MacCoss; David L Tabb; Parag Mallick
Journal:  Nat Biotechnol       Date:  2012-10       Impact factor: 54.908

10.  Improved batch correction in untargeted MS-based metabolomics.

Authors:  Ron Wehrens; Jos A Hageman; Fred van Eeuwijk; Rik Kooke; Pádraic J Flood; Erik Wijnker; Joost J B Keurentjes; Arjen Lommen; Henriëtte D L M van Eekelen; Robert D Hall; Roland Mumm; Ric C H de Vos
Journal:  Metabolomics       Date:  2016-03-18       Impact factor: 4.290

View more
  6 in total

Review 1.  Minimally Invasive Biospecimen Collection for Exposome Research in Children's Health.

Authors:  Lauren M Petrick; Manish Arora; Megan M Niedzwiecki
Journal:  Curr Environ Health Rep       Date:  2020-09

2.  Volumetric Absorptive Microsampling of Blood for Untargeted Lipidomics.

Authors:  Camilla Marasca; Maria Encarnacion Blanco Arana; Michele Protti; Andrea Cavalli; Laura Mercolini; Andrea Armirotti
Journal:  Molecules       Date:  2021-01-07       Impact factor: 4.411

3.  Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics.

Authors:  Cathy M Jacobs; Lea Wagmann; Markus R Meyer
Journal:  Anal Bioanal Chem       Date:  2021-01-30       Impact factor: 4.142

4.  Innovations in Prospective Perinatal Research as a Result Of the COVID-19 Pandemic.

Authors:  Katherine Kissler; Rachel Blankstein Breman; Nicole Carlson; Ellen Tilden; Elise Erickson; Julia Phillippi
Journal:  J Midwifery Womens Health       Date:  2022-02-15       Impact factor: 2.891

5.  Metabolic reprogramming of Salmonella infected macrophages and its modulation by iron availability and the mTOR pathway.

Authors:  Julia Telser; Chiara Volani; Richard Hilbe; Markus Seifert; Natascha Brigo; Giuseppe Paglia; Günter Weiss
Journal:  Microb Cell       Date:  2019-11-14

Review 6.  From bedside to bench-practical considerations to avoid pre-analytical pitfalls and assess sample quality for high-resolution metabolomics and lipidomics analyses of body fluids.

Authors:  Rainer Lehmann
Journal:  Anal Bioanal Chem       Date:  2021-06-22       Impact factor: 4.142

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.