Varying ultrasound power level to distinguish surgical instruments and tissue.

Hongliang Ren1, Banani Anuraj2, Pierre E Dupont3.   

Abstract

We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

Entities:  

Keywords:  Beating-heart interventions; Image overlay; Minimally invasive procedures; Power varying; Surgical robotics; Ultrasound guidance

Mesh:

Year:  2017        PMID: 28808900      PMCID: PMC6257990          DOI: 10.1007/s11517-017-1695-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Wavelet-based statistical approach for speckle reduction in medical ultrasound images.

Authors:  S Gupta; R C Chauhan; S C Sexana
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

2.  Passive markers for tracking surgical instruments in real-time 3-D ultrasound imaging.

Authors:  Jeffrey Stoll; Hongliang Ren; Pierre E Dupont
Journal:  IEEE Trans Med Imaging       Date:  2011-10-25       Impact factor: 10.048

3.  Design and Control of Concentric-Tube Robots.

Authors:  Pierre E Dupont; Jesse Lock; Brandon Itkowitz; Evan Butler
Journal:  IEEE Trans Robot       Date:  2010-04-01       Impact factor: 5.567

4.  Force Control of Flexible Catheter Robots for Beating Heart Surgery.

Authors:  Samuel B Kesner; Robert D Howe
Journal:  IEEE Int Conf Robot Autom       Date:  2011

5.  Detection of Curved Robots using 3D Ultrasound.

Authors:  Hongliang Ren; Nikolay V Vasilyev; Pierre E Dupont
Journal:  Rep U S       Date:  2011-09-25

6.  Tubular structure enhancement for surgical instrument detection in 3D ultrasound.

Authors:  Hongliang Ren; Pierre E Dupont
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

7.  Concentric Tube Robot Design and Optimization Based on Task and Anatomical Constraints.

Authors:  Christos Bergeles; Andrew H Gosline; Nikolay V Vasilyev; Patrick J Codd; Pedro J Del Nido; Pierre E Dupont
Journal:  IEEE Trans Robot       Date:  2015-02-03       Impact factor: 5.567

8.  Three-dimensional echocardiography-guided beating-heart surgery without cardiopulmonary bypass: a feasibility study.

Authors:  Yoshihiro Suematsu; Gerald R Marx; Jeffrey A Stoll; Pierre E DuPont; Robin O Cleveland; Robert D Howe; John K Triedman; Tomislav Mihaljevic; Bassem N Mora; Bernie J Savord; Ivan S Salgo; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2004-10       Impact factor: 5.209

9.  Percutaneous steerable robotic tool delivery platform and metal microelectromechanical systems device for tissue manipulation and approximation: closure of patent foramen ovale in an animal model.

Authors:  Nikolay V Vasilyev; Andrew H Gosline; Evan Butler; Nora Lang; Patrick J Codd; Haruo Yamauchi; Eric N Feins; Chris R Folk; Adam L Cohen; Richard Chen; David Zurakowski; Pedro J del Nido; Pierre E Dupont
Journal:  Circ Cardiovasc Interv       Date:  2013-07-30       Impact factor: 6.546

10.  Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools.

Authors:  Andrew H Gosline; Nikolay V Vasilyev; Evan J Butler; Chris Folk; Adam Cohen; Rich Chen; Nora Lang; Pedro J Del Nido; Pierre E Dupont
Journal:  Int J Rob Res       Date:  2012-08-01       Impact factor: 4.703

View more
  3 in total

1.  High dynamic range ultrasound imaging.

Authors:  Alperen Degirmenci; Douglas P Perrin; Robert D Howe
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-16       Impact factor: 2.924

2.  Dispersion characterization of magnetic actuated needleless injections with particle image velocimetry.

Authors:  Mavis Qin Ying Yee; Bok Seng Yeow; Hongliang Ren
Journal:  Med Biol Eng Comput       Date:  2019-09-12       Impact factor: 2.602

3.  Optically-guided instrument for transapical beating-heart delivery of artificial mitral chordae tendineae.

Authors:  Zurab Machaidze; Margherita Mencattelli; Gustavo Arnal; Karl Price; Fei-Yi Wu; Viktoria Weixler; David W Brown; John E Mayer; Pierre E Dupont
Journal:  J Thorac Cardiovasc Surg       Date:  2019-03-21       Impact factor: 5.209

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.