Literature DB >> 28794577

MRMC analysis of agreement studies.

Brandon D Gallas1, Amrita Anam1,2, Weijie Chen1, Adam Wunderlich1, Zhiwei Zhang3.   

Abstract

The purpose of this work is to present and evaluate methods based on U-statistics to compare intra- or inter-reader agreement across different imaging modalities. We apply these methods to multi-reader multi-case (MRMC) studies. We measure reader-averaged agreement and estimate its variance accounting for the variability from readers and cases (an MRMC analysis). In our application, pathologists (readers) evaluate patient tissue mounted on glass slides (cases) in two ways. They evaluate the slides on a microscope (reference modality) and they evaluate digital scans of the slides on a computer display (new modality). In the current work, we consider concordance as the agreement measure, but many of the concepts outlined here apply to other agreement measures. Concordance is the probability that two readers rank two cases in the same order. Concordance can be estimated with a U-statistic and thus it has some nice properties: it is unbiased, asymptotically normal, and its variance is given by an explicit formula. Another property of a U-statistic is that it is symmetric in its inputs; it doesn't matter which reader is listed first or which case is listed first, the result is the same. Using this property and a few tricks while building the U-statistic kernel for concordance, we get a mathematically tractable problem and efficient software. Simulations show that our variance and covariance estimates are unbiased.

Entities:  

Year:  2016        PMID: 28794577      PMCID: PMC5546377          DOI: 10.1117/12.2217074

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  3 in total

1.  An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

Authors:  Nancy A Obuchowski
Journal:  Stat Med       Date:  2006-02-15       Impact factor: 2.373

2.  A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area.

Authors:  W D Smith; R C Dutton; N T Smith
Journal:  Stat Med       Date:  1996-06-15       Impact factor: 2.373

3.  Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: validation with computer simulation.

Authors:  C A Roe; C E Metz
Journal:  Acad Radiol       Date:  1997-04       Impact factor: 3.173

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.