Literature DB >> 28785993

Quantification of the radiation dose to the pyramidal tract using tractography in treatment planning for stereotactic radiosurgery.

Kohei Kawasaki1, Masanobu Matsumoto2, Masayuki Kase3, Osamu Nagano4, Kyoko Aoyagi4, Takahiro Kageyama2.   

Abstract

In stereotactic radiosurgery for intracranial lesions, optimization of the dose to the at-risk organs is important to avoid neurological complications. We aimed to quantify the dose to the pyramidal tract (PT) and improve treatment planning for gamma knife radiosurgery by combining tractography. Pyramidal tractography images were depicted in 23 patients with lesions adjacent to the PT and fused with stereotactic magnetic resonance images. We regarded the PT as an at-risk organ and performed dose planning. To assess the efficacy of this process, we compared clinical parameters between plans with and without tractography. In the plans with tractography, the maximum PT dose was significantly reduced, although the irradiation time was prolonged by 3.5 min. There was no significant difference in the dose covering 95% of the lesion volume (D95). This result suggests that the PT dose can be reduced while maintaining the D95 with clinically acceptable prolongation of the irradiation time.

Entities:  

Keywords:  At-risk organ; Pyramidal tract; Radiation dose evaluation; Stereotactic radiosurgery; Tractography; Treatment planning

Mesh:

Year:  2017        PMID: 28785993     DOI: 10.1007/s12194-017-0411-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  14 in total

1.  Brain fiber tracking with clinically feasible diffusion-tensor MR imaging: initial experience.

Authors:  Kei Yamada; Osamu Kizu; Susumu Mori; Hirotoshi Ito; Hisao Nakamura; Sachiko Yuen; Takao Kubota; Osamu Tanaka; Wataru Akada; Hiroyasu Sasajima; Katsuyoshi Mineura; Tsunehiko Nishimura
Journal:  Radiology       Date:  2003-04       Impact factor: 11.105

2.  Outcomes of diffusion tensor tractography-integrated stereotactic radiosurgery.

Authors:  Tomoyuki Koga; Keisuke Maruyama; Kyousuke Kamada; Takahiro Ota; Masahiro Shin; Daisuke Itoh; Naoto Kunii; Kenji Ino; Atsuro Terahara; Shigeki Aoki; Yoshitaka Masutani; Nobuhito Saito
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-27       Impact factor: 7.038

Review 3.  Twenty-five pitfalls in the analysis of diffusion MRI data.

Authors:  Derek K Jones; Mara Cercignani
Journal:  NMR Biomed       Date:  2010-08       Impact factor: 4.044

4.  Stereotactic diffusion tensor imaging tractography for Gamma Knife radiosurgery.

Authors:  Cormac G Gavin; H Ian Sabin
Journal:  J Neurosurg       Date:  2016-12       Impact factor: 5.115

5.  Integration of three-dimensional corticospinal tractography into treatment planning for gamma knife surgery.

Authors:  Keisuke Maruyama; Kyousuke Kamada; Masahiro Shin; Daisuke Itoh; Shigeki Aoki; Yoshitaka Masutani; Masao Tago; Takaaki Kirino
Journal:  J Neurosurg       Date:  2005-04       Impact factor: 5.115

6.  Diffusion tensor tractography of the Meyer loop in cases of temporal lobe resection for temporal lobe epilepsy: correlation between postsurgical visual field defect and anterior limit of Meyer loop on tractography.

Authors:  T Taoka; M Sakamoto; H Nakagawa; H Nakase; S Iwasaki; K Takayama; K Taoka; T Hoshida; T Sakaki; K Kichikawa
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-01       Impact factor: 3.825

7.  Stereotactic radiosurgery for arteriovenous malformations of the brain.

Authors:  L D Lunsford; D Kondziolka; J C Flickinger; D J Bissonette; C A Jungreis; A H Maitz; J A Horton; R J Coffey
Journal:  J Neurosurg       Date:  1991-10       Impact factor: 5.115

8.  Stereotactic radiosurgery for patients with multiple brain metastases (JLGK0901): a multi-institutional prospective observational study.

Authors:  Masaaki Yamamoto; Toru Serizawa; Takashi Shuto; Atsuya Akabane; Yoshinori Higuchi; Jun Kawagishi; Kazuhiro Yamanaka; Yasunori Sato; Hidefumi Jokura; Shoji Yomo; Osamu Nagano; Hiroyuki Kenai; Akihito Moriki; Satoshi Suzuki; Yoshihisa Kida; Yoshiyasu Iwai; Motohiro Hayashi; Hiroaki Onishi; Masazumi Gondo; Mitsuya Sato; Tomohide Akimitsu; Kenji Kubo; Yasuhiro Kikuchi; Toru Shibasaki; Tomoaki Goto; Masami Takanashi; Yoshimasa Mori; Kintomo Takakura; Naokatsu Saeki; Etsuo Kunieda; Hidefumi Aoyama; Suketaka Momoshima; Kazuhiro Tsuchiya
Journal:  Lancet Oncol       Date:  2014-03-10       Impact factor: 41.316

9.  Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: a 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C.

Authors:  Jean Régis; Manabu Tamura; Cécile Guillot; Shoji Yomo; Xavier Muraciolle; Mariko Nagaje; Yasser Arka; Denis Porcheron
Journal:  Neurosurgery       Date:  2009-02       Impact factor: 4.654

Review 10.  Oligometastases and oligo-recurrence: the new era of cancer therapy.

Authors:  Yuzuru Niibe; Kazushige Hayakawa
Journal:  Jpn J Clin Oncol       Date:  2010-01-04       Impact factor: 3.019

View more
  3 in total

1.  Evaluation of local look diffusion tensor imaging for magnetic resonance tractography of the periprostatic neurovascular bundle.

Authors:  Wataru Jomoto; Masao Tanooka; Tsukasa Wakayama; Takahiro Minamoto; Toru Suzuki; Reiichi Ishikura; Shingo Yamamoto; Noriko Kotoura
Journal:  Radiol Phys Technol       Date:  2018-08-04

Review 2.  Tractography methods and findings in brain tumors and traumatic brain injury.

Authors:  Fang-Cheng Yeh; Andrei Irimia; Dhiego Chaves de Almeida Bastos; Alexandra J Golby
Journal:  Neuroimage       Date:  2021-10-18       Impact factor: 6.556

3.  Compression of the middle cerebellar tract by posterior fossa tumors before and after Gamma Knife radiosurgery studied with diffusion tensor imaging.

Authors:  Herwin Speckter; Jose Bido; Giancarlo Hernandez; Diones Rivera; Luis Suazo; Santiago Valenzuela; Cesar Gonzalez; Peter Stoeter
Journal:  J Radiosurg SBRT       Date:  2019
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.