Literature DB >> 28781632

Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates.

Xin-Jia Hu1, Hua Wang1.   

Abstract

The aim of the present study was to investigate the biomechanical effects of varying the length of a limited contact-dynamic compression plate (LC-DCP) and the number and position of screws on middle tibial fractures, and to provide biomechanical evidence regarding minimally invasive plate osteosynthesis (MIPO). For biomechanical testing, 60 tibias from cadavers (age at mortality, 20-40 years) were used to create middle and diagonal fracture models without defects. Tibias were randomly grouped and analyzed by biomechanic and three-dimensional (3D) finite element analysis. The differences among LC-DCPs of different lengths (6-, 10- and 14-hole) with 6 screws, 14-hole LC-DCPs with different numbers of screws (6, 10 and 14), and 14-hole LC-DCPs with 6 screws at different positions with regard to mechanical characteristics, including compressing, torsion and bending, were examined. The 6-hole LC-DCP had greater vertical compression strain compared with the 10- and 14-hole LC-DCPs (P<0.01), and the 14-hole LC-DCP had greater lateral strain than the 6- and 10-hole LC-DCPs (P<0.01). Furthermore, significant differences in torque were observed among the LC-DPs of different lengths (P<0.01). For 14-hole LC-DCPs with different numbers of screws, no significant differences in vertical strain, lateral strain or torque were detected (P>0.05). However, plates with 14 screws had greater vertical strain compared with those fixed with 6 or 10 screws (P<0.01). For 4-hole LC-DCPs with screws at different positions, vertical compression strain values were lowest for plates with screws at positions 1, 4, 7, 8, 11 and 14 (P<0.01). The lateral strain values and vertical strain values for plates with screws at positions 1, 3, 6, 9, 12 and 14 were significantly lower compared with those at the other positions (P<0.01), and torque values were also low. Thus, the 14-hole LC-DCP was the most stable against vertical compression, torsion and bending, and the 6-hole LC-DCP was the least stable. However, the use of 14 screws with a 14-hole LC-DCP provided less stability against bending than did 6 or 10 screws. Furthermore, fixation with distributed screws, in which some screws were close to the fracture line, provided good stability against compression and torsion, while fixation with screws at the ends of the LC-DCP provided poor stability against bending, compressing and torsion.

Entities:  

Keywords:  biomechanics; finite element analysis; internal fixation; tibial fractures

Year:  2017        PMID: 28781632      PMCID: PMC5526180          DOI: 10.3892/etm.2017.4629

Source DB:  PubMed          Journal:  Exp Ther Med        ISSN: 1792-0981            Impact factor:   2.447


  15 in total

1.  Screw position affects dynamic compression plate strain in an in vitro fracture model.

Authors:  T Ellis; C A Bourgeault; R F Kyle
Journal:  J Orthop Trauma       Date:  2001 Jun-Jul       Impact factor: 2.512

2.  Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach.

Authors:  Fang Ji; Dake Tong; Hao Tang; Xiaobing Cai; Qiulin Zhang; Jingfeng Li; Qiugen Wang
Journal:  Int Orthop       Date:  2008-03-04       Impact factor: 3.075

3.  [Computer simulation of the isolated lesion of tibiofibular an syndesmosis using the finite element method].

Authors:  Marek S Kozień; Jacek Lorkowski; Sławomir Szczurek; Waldemar Hładki; Marek Trybus
Journal:  Przegl Lek       Date:  2008

4.  Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique?

Authors:  O Farouk; C Krettek; T Miclau; P Schandelmaier; P Guy; H Tscherne
Journal:  J Orthop Trauma       Date:  1999-08       Impact factor: 2.512

5.  The evolution of femoral shaft plating technique.

Authors:  S R Rozbruch; U Müller; E Gautier; R Ganz
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

6.  Minimally invasive plate osteosynthesis of distal fractures of the tibia.

Authors:  D L Helfet; P Y Shonnard; D Levine; J Borrelli
Journal:  Injury       Date:  1997       Impact factor: 2.586

Review 7.  Innovations in locking plate technology.

Authors:  George J Haidukewych
Journal:  J Am Acad Orthop Surg       Date:  2004 Jul-Aug       Impact factor: 3.020

8.  Less invasive stabilization of complex tibial plateau fractures: a biomechanical evaluation of a unilateral locked screw plate and double plating.

Authors:  T Gösling; P Schandelmaier; A Marti; T Hufner; A Partenheimer; C Krettek
Journal:  J Orthop Trauma       Date:  2004-09       Impact factor: 2.512

9.  [Technology of minimally invasive percutancous plate osteosynthesis for the treatment of fractures of the distal tibia].

Authors:  Cheng-zhao Liu; Li-yong Wu; Xiao-yu He; Chun Wang
Journal:  Zhongguo Gu Shang       Date:  2008-03

10.  The effect of early versus delayed surgical debridement on the outcome of open long bone fractures at Bugando Medical Centre, Mwanza, Tanzania.

Authors:  Njee Nobert; Nyambura Moremi; Jeremiah Seni; Ramesh M Dass; Isdori H Ngayomela; Stephen E Mshana; Japhet M Gilyoma
Journal:  J Trauma Manag Outcomes       Date:  2016-07-04
View more
  2 in total

1.  Finite element analysis modeling of plates versus intramedullary nails in closed comminuted midshaft tibial fractures.

Authors:  Mahmoud Ahmed El-Desouky; Ayman Ali Saleh; Sherif Mamdouh Amr; Ahmed Samir Barakat
Journal:  SICOT J       Date:  2022-06-16

2.  Three-Dimensional Biomechanical Finite Element Analysis of Lumbar Disc Herniation in Middle Aged and Elderly.

Authors:  Shiyuan Wan; Bin Xue; Yanhao Xiong
Journal:  J Healthc Eng       Date:  2022-01-15       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.