Literature DB >> 19105443

[Technology of minimally invasive percutancous plate osteosynthesis for the treatment of fractures of the distal tibia].

Cheng-zhao Liu1, Li-yong Wu, Xiao-yu He, Chun Wang.   

Abstract

OBJECTIVE: To explore the technique and clinical results of minimally invasive percutancous plate osteosynthesis (MIPPO) for the treatment of fractures of the distal tibia.
METHODS: A retrospective study was conducted to analyze 65 patients with the distal tibia fractures who had been treated with MIPPO. The average age of the patients was 35 years old (ranging from 13 to 75). There were 42 males and 23 females. According to AO fracture classification for the distal tibial fractures, there were 5 cases of type-A1 fracture, 22 type-A2, 32 type-A3 and 6 type-C1.
RESULTS: All the patients were followed up and ranged from 6 to 18 months (averaged 11 months). All the fractures showed union. The time required for the bony union ranged from 3 to 6 months (averaged 4.5 months). The patients were evaluated with respect to functional recovery according to Mazur Grating System for the Ankle. Forty patients obtained excellent results, 19 good and 6 fair. The total satisfactory rate was 90.7%.
CONCLUSION: The technology of minimally invasive percutancous plate osteosynthesis (MIPPO)is a safe and effective procedure for the distal tibial fractures with the benefits of limited invasion,less complications and high rate of bone union.

Entities:  

Mesh:

Year:  2008        PMID: 19105443

Source DB:  PubMed          Journal:  Zhongguo Gu Shang        ISSN: 1003-0034


  1 in total

1.  Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates.

Authors:  Xin-Jia Hu; Hua Wang
Journal:  Exp Ther Med       Date:  2017-06-20       Impact factor: 2.447

  1 in total