| Literature DB >> 28751685 |
Anne Marie Kinn Rød1, Nina Harkestad2, Finn Konow Jellestad2, Robert Murison2.
Abstract
Enzyme-linked immunosorbent assay (ELISA) kits are widely used to quantify corticosterone levels for the assessment of stress in laboratory animals. The aim of this experiment was simply to evaluate if four different and widely used commercial ELISA assays would yield the same or similar values of corticosterone in serum samples taken from laboratory rats after the mild stress of being held for sampling blood from the saphenous vein. Trunk blood was sampled from 32 male Wistar rats 30 minutes after this mild stress exposure and analysed with each of four commercial ELISA kits. Both the Arbor Assays and the DRG-4164 kits were significantly higher than the DRG-5186 and the Enzo kits. There were no significant differences between the DRG-5186 and Enzo kits. Overall the correlations between kits were high. In conclusion, the commercial ELISA kits tested in the present experiment yielded different values of total corticosterone in the same serum samples. The precision in determining true values of the corticosterone level is low for these commercial ELISA kits, although they may be used to determine relative differences within studies.Entities:
Mesh:
Substances:
Year: 2017 PMID: 28751685 PMCID: PMC5532291 DOI: 10.1038/s41598-017-06006-4
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Information from manufacturers kit manual and included in the kits.
| DRG-5186 | DRG-4164 | Enzo | Arbor Assays | |
|---|---|---|---|---|
| Standard series: | 15–2250 ng/ml. | 1.7–83 ng/ml | 0.032–20 ng/ml. | 0.078–10 ng/ml |
| Analytical sensitivity: | 4.1 ng/ml | 0.5647 ng/ml | 0.02699 ng/ml | 0.0186 ng/ml |
| Amount of sample (for dilution): | 20 µl | 10 µl | 10 µl | 5 µl |
| Sample dilution: | 1:1 | 1:10 | 1:40 | 1:100 |
| Release from CBG: | n.s. | n.s. | YES | YES |
| Internal quality control | Yes* | Yes | No | No |
| Cross reactivity (%): | ||||
| Progesterone | 0.7 | 7.4 | 1.7 | 0.24 |
| Aldosterone | 0.2 | n.a. | 0.18 | 0.62 |
| Cortisol | 0.3 | 0.3 | 0.046 | 0.38 |
| 11-Deoxycorticosterone | 2.4 | 3.4 | 28.6 | 12.3 |
| Dehydroepiandrosterone | n.d. | n.a. | n.a. | n.a. |
| Estriol | n.d. | n.a. | n.a. | n.a. |
| Estradiol | n.d. | n.a. | n.a. | <0.08 |
| 17-hydroxyprogesterone | n.d. | n.a. | n.a. | n.a. |
| 18-Hydroxydeoxycorticosterone | n.d. | n.a. | n.a. | n.a. |
| Testosterone | n.d. | n.a. | 0.13 | n.a. |
| Pregnolone Prognenolone | n.d. | 0.3 | <0.03 | n.a. |
| 11-Dehydrocorticosterone | n.a. | 1.6 | n.a. | n.a. |
| Tetrahydrocorticosterone | n.a. | n.a. | 0.28 | 0.76 |
| β-Estradiol | n.a. | n.a. | <0.03 | n.a. |
| Cortisone | n.a. | n.a. | <0.03 | <0.08 |
| 11-dehydrocorticosterone acetate | n.a. | n.a. | <0.03 | n.a. |
| Dexamethasone | n.a. | n.a. | n.a. | 0.12 |
| Corticosterone-21-Hemisuccinate | n.a. | n.a. | n.a. | <0.1 |
| Other steroids | n.a. | <0.1 | n.a. | n.a. |
*Recommended quality control kit (DRG CTL-5262). CBG -Corticosteroid-binding globulin; n.s. not specified in the manual; n.d. cross reactivity not detected for these substances; n.a. the cross reactivity is not assessed for these substances.
Figure 1Corticosterone (ng/ml) measured in the four ELISA assays. Bars and whiskers indicate mean + Std.dev. ***p < 0.001 difference from DRG-5186 and from Enzo (Kruskal-Wallis test).