Literature DB >> 28734611

Survivorship of a Porous Tantalum Monoblock Acetabular Component in Primary Hip Arthroplasty With a Mean Follow-Up of 18 Years.

George A Macheras1, Panagiotis Lepetsos1, Andreas O Leonidou1, Panagiotis P Anastasopoulos1, Spyridon P Galanakos1, Lazaros A Poultsides2.   

Abstract

BACKGROUND: The use of porous tantalum for the acetabular component in primary total hip arthroplasty (THA) has demonstrated excellent short-term and midterm results. However, long-term data are scarce. The purpose of this prospective study is to report the long-term clinical and radiologic outcome following use of an uncemented porous tantalum acetabular component in primary THA with a minimum follow-up of 17.5 years, in a previously studied cohort of patients.
METHODS: We prospectively followed 128 consecutive primary THAs in 140 patients, between November 1997 and June 1999. A press-fit porous tantalum monoblock acetabular component was used in all cases. All patients were followed clinically and radiographically for a mean of 18.1 years (range, 17.5-19 years).
RESULTS: Mean age of patients at the time of operation was 60.4 years. Harris hip score, Oxford hip score, and range of motion were dramatically improved in all cases (P < .001). At last follow-up, all cups were radiographically stable with no evidence of migration, gross polyethylene wear, progressive radiolucencies, osteolytic lesions, or acetabular fractures. The survivorship with reoperation for any reason as end point was 92.8% and the survivorship for aseptic loosening as an end point was 100%.
CONCLUSION: The porous tantalum monoblock cup in primary THA demonstrated excellent clinical and radiographic outcomes with no failures because of aseptic loosening at a mean follow-up of 18.1 years.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  long-term follow-up; monoblock acetabular cup; porous tantalum; total hip arthroplasty; trabecular metal

Mesh:

Substances:

Year:  2017        PMID: 28734611     DOI: 10.1016/j.arth.2017.06.049

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  A new 3D printing porous trabecular titanium metal acetabular cup for primary total hip arthroplasty: a minimum 2-year follow-up of 92 consecutive patients.

Authors:  Xiao Geng; Yang Li; Feng Li; Xinguang Wang; Ke Zhang; Zhongjun Liu; Hua Tian
Journal:  J Orthop Surg Res       Date:  2020-09-04       Impact factor: 2.359

2.  Total hip arthroplasty using a three-dimensional porous titanium acetabular cup: an examination of micromotion using subject-specific finite element analysis.

Authors:  Takaki Miyagawa; Kazu Matsumoto; Shingo Komura; Haruhiko Akiyama
Journal:  BMC Musculoskelet Disord       Date:  2021-03-26       Impact factor: 2.362

3.  Evaluation of the bone morphology around four types of porous metal implants placed in distal femur of ovariectomized rats.

Authors:  Stanislav Bondarenko; Nataliya Ashukina; Valentyna Maltseva; Gennadiy Ivanov; Ahmed Amine Badnaoui; Ran Schwarzkopf
Journal:  J Orthop Surg Res       Date:  2020-08-03       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.