Literature DB >> 28719967

Is a Cytopathologist Always Needed during Endoscopic Ultrasonography-Guided Tissue Acquisition?

Moon Won Lee1, Gwang Ha Kim1.   

Abstract

Entities:  

Year:  2017        PMID: 28719967      PMCID: PMC5565051          DOI: 10.5946/ce.2017.103

Source DB:  PubMed          Journal:  Clin Endosc        ISSN: 2234-2400


× No keyword cloud information.
See "Rapid On-Site Evaluation by Endosonographers during Endoscopic Ultrasonography-Guided Fine-Needle Aspiration for Diagnosis of Gastrointestinal Stromal Tumors" by Takashi Tamura, Yasunobu Yamashita, Kazuki Ueda, et al., 372-378. Gastrointestinal (GI) subepithelial tumors (SETs) detected during routine endoscopy demonstrate a prevalence of 0.36%, which is found to increase with age [1]. Based on a recent Korean multicenter study that included 87,578 subjects undergoing routine screening endoscopy, the incidence of SETs in the upper GI tract was noted to be 3.1% (unpublished data). GI SETs include malignant tumors (such as GI stromal tumors, neuroendocrine tumors, or lymphomas), as well as benign tumors (such as leiomyomas, lipomas, heterotopic pancreas, or cysts). Although surgical resection is the primary diagnostic and therapeutic modality used for management of SETs, particularly for symptomatic or large tumors, it might not be needed for all cases with SETs. Although endoscopic ultrasonography (EUS) is the best diagnostic modality for evaluation of SETs, it cannot be a substitute for a histopathological diagnosis. Because a histopathological diagnosis plays an important role in determining the most appropriate treatment strategy, EUS-guided tissue acquisition such as fine-needle aspiration (FNA) is attempted in many clinical settings. EUS-FNA is a well-known and useful diagnostic modality for the management of solid pancreatic lesions. Rapid on-site evaluation (ROSE) performed by an attending cytopathologist can improve the adequacy rate of FNA specimens, resulting in a higher diagnostic yield of EUS and can reduce the number of needle passes required/performed [2,3]. ROSE can also be performed by endoscopists instead of cytopathologists. A retrospective study compared the diagnostic accuracy of EUS-FNA with ROSE performed by endoscopists and cytopathologists and found no statistically significant differences between the two groups (endoscopists and cytopathologists) with respect to the mean number of passes required (4.0±1.6 vs. 3.4±1.5, p=0.06) and specimen adequacy (97.4% vs. 97.1%, p=0.51) [4]. Another recent study showed that endoscopists who participated in pathologist-guided training programs could improve the adequacy of specimens (from 75% to 98%) and diagnostic accuracy (from 61% to 82%) [5]. However, a recent, multicenter, prospective, randomized controlled trial using EUS-FNA for pancreatic lesions, showed that the diagnostic yield and proportion of inadequate specimens did not differ between EUS-FNA performed with and without ROSE [6]. A meta-analysis comprising seven studies involving 1,299 patients, compared EUS-FNA performed with and without ROSE and showed that ROSE did not significantly affect the cytological adequacy or diagnostic yield [7]. This is because, due to rapidly advancing technology, EUS-FNA has become a widely used diagnostic procedure, and endoscopists are now better equipped to target lesions and obtain samples even from very small pancreatic lesions along with maintaining proper positioning of the needle under direct visualization while the sample is being collected. Thus, on-site assistance from pathologists has become less relevant [8]. Additionally, recent studies using a newly developed ProCore needle (Cook Medical Inc., Bloomington, IN, USA) has shown similar results [9,10]. Reportedly, the diagnostic accuracy of EUS-FNA for GI SETs is 50%–70% in GI mesenchymal tumors [11-13]. Immunohistochemical staining is mandatory for accurate diagnosis of GI SETs, especially GI mesenchymal tumors such as GI tumors, schwannomas, or leiomyomas. This technique necessitates acquisition of histologically optimal core samples. Thus, several new EUS-guided tissue acquisition needles, such as the ProCore or Shark Core (Beacon™ Endoscopy; Medtronic Inc., Minneapolis, MN, USA) have been developed. A recent, prospective, multicenter study investigating GI SETs showed that EUS-guided fine-needle biopsy using a ProCore needle significantly decreased the median number of needle passes required (4 vs. 2) and additionally increased the diagnostic sufficiency rate (75% vs. 20%) compared to EUS-FNA [14]. In this issue of Clinical Endoscopy, Tamura et al. report that ROSE performed by endosonographers during an EUS-FNA for GI SETs resulted in a higher diagnostic accuracy and need for a fewer number of needle passes [15]. It is notable that ROSE performed by endosonographers and not by cytopathologists could improve the diagnostic yield of EUS-FNA in management of GI SETs. As stated above, newly developed needles, such as the ProCore needle can also reproduce the merits of ROSE. However, if after obtaining appropriate training, endosonographers can independently perform ROSE for evaluation of histopathological specimens, the combined use of newer instruments and ROSE would have a synergistic effect in increasing the diagnostic yield of EUS-guided tissue acquisition in management of GI SETs.
  15 in total

1.  Does on-site adequacy evaluation reduce the nondiagnostic rate in endoscopic ultrasound-guided fine-needle aspiration of pancreatic lesions?

Authors:  Therese S Cermak; Brant Wang; Pedro DeBrito; John Carroll; Nadim Haddad; Mary K Sidawy
Journal:  Cancer Cytopathol       Date:  2012-04-19       Impact factor: 5.284

2.  Rapid on-site evaluation reduces needle passes in endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: a risk-benefit analysis.

Authors:  Robert L Schmidt; Brandon S Walker; Kirsten Howard; Lester J Layfield; Douglas G Adler
Journal:  Dig Dis Sci       Date:  2013-07-04       Impact factor: 3.199

3.  An expanded training program for endosonographers improved self-diagnosed accuracy of endoscopic ultrasound-guided fine-needle aspiration cytology of the pancreas.

Authors:  Ryo Harada; Hironari Kato; Soichiro Fushimi; Masaya Iwamuro; Hirofumi Inoue; Shinichiro Muro; Ichiro Sakakihara; Yasuhiro Noma; Naoki Yamamoto; Shigeru Horiguchi; Koichiro Tsutsumi; Hiroyuki Okada; Kazuhide Yamamoto
Journal:  Scand J Gastroenterol       Date:  2014-06-04       Impact factor: 2.423

4.  Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses.

Authors:  Julio Iglesias-Garcia; J Enrique Dominguez-Munoz; Ihab Abdulkader; Jose Larino-Noia; Elena Eugenyeva; Antonio Lozano-Leon; Jeronimo Forteza-Vila
Journal:  Am J Gastroenterol       Date:  2011-04-12       Impact factor: 10.864

5.  Comparison of 22-gauge aspiration needle with 22-gauge biopsy needle in endoscopic ultrasonography-guided subepithelial tumor sampling.

Authors:  Gwang Ha Kim; Yu Kyung Cho; Eun Young Kim; Hyung Kil Kim; Jin Woong Cho; Tae Hee Lee; Jeong Seop Moon
Journal:  Scand J Gastroenterol       Date:  2013-12-11       Impact factor: 2.423

6.  The presence of rapid on-site evaluation did not increase the adequacy and diagnostic accuracy of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions with core needle.

Authors:  Carlo Fabbri; Lorenzo Fuccio; Adele Fornelli; Filippo Antonini; Rosa Liotta; Leonardo Frazzoni; Alberto Larghi; Antonella Maimone; Silvia Paggi; Paolo Gusella; Luca Barresi; Anna Maria Polifemo; Elio Iovine; Giampiero Macarri; Vincenzo Cennamo; Ilaria Tarantino
Journal:  Surg Endosc       Date:  2016-05-18       Impact factor: 4.584

7.  Endoscopic diagnosis of submucosal gastric lesions. The results after routine endoscopy.

Authors:  J L Hedenbro; M Ekelund; P Wetterberg
Journal:  Surg Endosc       Date:  1991       Impact factor: 4.584

8.  The clinical impact of immediate on-site cytopathology evaluation during endoscopic ultrasound-guided fine needle aspiration of pancreatic masses: a prospective multicenter randomized controlled trial.

Authors:  Sachin Wani; Daniel Mullady; Dayna S Early; Amit Rastogi; Brian Collins; Jeff F Wang; Carrie Marshall; Sharon B Sams; Roy Yen; Mona Rizeq; Maria Romanas; Ozlem Ulusarac; Brian Brauer; Augustin Attwell; Srinivas Gaddam; Thomas G Hollander; Lindsay Hosford; Sydney Johnson; Vladimir Kushnir; Stuart K Amateau; Cara Kohlmeier; Riad R Azar; John Vargo; Norio Fukami; Raj J Shah; Ananya Das; Steven A Edmundowicz
Journal:  Am J Gastroenterol       Date:  2015-09-08       Impact factor: 10.864

9.  Endosonographic large-bore biopsy of gastric subepithelial tumors: a prospective multicenter study.

Authors:  Alexander J Eckardt; Andreas Adler; Eleonora M Gomes; Christian Jenssen; Christine Siebert; Uwe Gottschalk; Martin Koch; Christoph Röcken; Thomas Rösch
Journal:  Eur J Gastroenterol Hepatol       Date:  2012-10       Impact factor: 2.566

10.  Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review.

Authors:  Fanyang Kong; Jianwei Zhu; Xiangyu Kong; Tao Sun; Xuan Deng; Yiqi Du; Zhaoshen Li
Journal:  PLoS One       Date:  2016-09-22       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.