Literature DB >> 28718054

Mass attenuation coefficient of tannin-added Rhizophora spp. particleboards at 16.59-25.56 keV photons, and 137Cs and 60Co gamma energies.

Mohd Fahmi Mohd Yusof1,2, Puteri Nor Khatijah Abd Hamid3, Abd Aziz Tajuddin3, Rokiah Hashim4, Sabar Bauk3, Norriza Mohd Isa5, Muhammad Jamal Md Isa5.   

Abstract

The aim of this study was to determine the suitability of tannin-added Rhizophora spp. particleboards as phantom materials in the application of low- and high-energy photons. The tannin-added Rhizophora spp. particleboards and density plug phantoms were created with a target density of 1.0 g/cm3. The elemental composition and effective atomic number of the particleboards were measured using energy dispersive X-ray analysis. The mass attenuation coefficient of the particleboards for low-energy photons were measured using the attenuation of X-ray fluorescence. The mass attenuation coefficients of high-energy photons were measured using the attenuation of 137Cs and 60Co gamma energies. The results were compared to the calculated value of water using XCOM calculations. The results showed that the effective atomic number and mass attenuation coefficients of tannin-added Rhizophora spp. particleboards were similar to those of water, indicating the suitability of tannin-added Rhizophora spp. particleboards as phantom materials for low- and high-energy photons.

Entities:  

Keywords:  Effective atomic number; Mass attenuation coefficient; Particleboards; Rhizophora spp.

Mesh:

Substances:

Year:  2017        PMID: 28718054     DOI: 10.1007/s12194-017-0408-3

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  5 in total

1.  Xylem water content and wood density in spruce and oak trees detected by high-resolution computed tomography.

Authors:  J H Fromm; I Sautter; D Matthies; J Kremer; P Schumacher; C Ganter
Journal:  Plant Physiol       Date:  2001-10       Impact factor: 8.340

2.  Measurement of mass attenuation coefficients of Rhizophora spp. binderless particleboards in the 16.59-25.26 keV photon energy range and their density profile using x-ray computed tomography.

Authors:  M W Marashdeh; S Bauk; A A Tajuddin; R Hashim
Journal:  Appl Radiat Isot       Date:  2012-01-20       Impact factor: 1.513

3.  Mass attenuation coefficients of natural Rhizophora spp. wood for X-rays in the 15.77-25.27 keV range.

Authors:  B Z Shakhreet; S Bauk; A A Tajuddin; A Shukri
Journal:  Radiat Prot Dosimetry       Date:  2009-05-29       Impact factor: 0.972

4.  Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT.

Authors:  Saxby Brown; Dale L Bailey; Kathy Willowson; Clive Baldock
Journal:  Appl Radiat Isot       Date:  2008-01-12       Impact factor: 1.513

5.  A protocol for the determination of absorbed dose from high-energy photon and electron beams.

Authors: 
Journal:  Med Phys       Date:  1983 Nov-Dec       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.