BACKGROUND: Ultrasound imaging is often used by physiotherapists and other healthcare professionals but the reliability of image acquisition with different ultrasound machines is unknown. The objective was to compare the intra-rater, inter-rater and intermachine reliability of thickness measurements of the plantar fascia (PF), Achilles tendon (AT), patellar tendon (PT) and elbow common extensor tendon (ECET) with musculoskeletal ultrasound imaging (MSUS). METHODS: Tendon thickness was measured in four anatomical structures (14 participants, 28 images per tendon) by two sonographers and with two different ultrasound machines. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were calculated. The standard error of measurement (SEM) and minimum detectable difference (MDD) were calculated. RESULTS: Inter-rater reliability was excellent for AT (ICC=0.98; 95% CI= 0.96-0.99) and very good for PT (ICC=0.85; 95% CI = 0.67-0.93) and ECET (ICC=0.81; 95% CI= 0.72-0.94). Reliability for PF was moderate, with an ICC of 0.63 (CI 95%= 0.20-0.83). Bland-Altman plot for inter-machine reliability showed a mean difference of 1 m for PF measurements and a mean difference of 4 m and 20 m for AT and PT. The relative SEMs were below 7% and the MDCs were below 0.7 mm. CONCLUSION: The MSUS reliability in measuring thickness of the four tendons is confirmed by the homogeneous readings intra sonographers, between operators and between different machines. Level of evidence: Tendon thickness can be measured reliably on different ultrasound devices, which is an important step forward in the use of this technique in daily clinical practice and research. LEVEL OF EVIDENCE: III.
BACKGROUND: Ultrasound imaging is often used by physiotherapists and other healthcare professionals but the reliability of image acquisition with different ultrasound machines is unknown. The objective was to compare the intra-rater, inter-rater and intermachine reliability of thickness measurements of the plantar fascia (PF), Achilles tendon (AT), patellar tendon (PT) and elbow common extensor tendon (ECET) with musculoskeletal ultrasound imaging (MSUS). METHODS: Tendon thickness was measured in four anatomical structures (14 participants, 28 images per tendon) by two sonographers and with two different ultrasound machines. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were calculated. The standard error of measurement (SEM) and minimum detectable difference (MDD) were calculated. RESULTS: Inter-rater reliability was excellent for AT (ICC=0.98; 95% CI= 0.96-0.99) and very good for PT (ICC=0.85; 95% CI = 0.67-0.93) and ECET (ICC=0.81; 95% CI= 0.72-0.94). Reliability for PF was moderate, with an ICC of 0.63 (CI 95%= 0.20-0.83). Bland-Altman plot for inter-machine reliability showed a mean difference of 1 m for PF measurements and a mean difference of 4 m and 20 m for AT and PT. The relative SEMs were below 7% and the MDCs were below 0.7 mm. CONCLUSION: The MSUS reliability in measuring thickness of the four tendons is confirmed by the homogeneous readings intra sonographers, between operators and between different machines. Level of evidence: Tendon thickness can be measured reliably on different ultrasound devices, which is an important step forward in the use of this technique in daily clinical practice and research. LEVEL OF EVIDENCE: III.
Authors: Mohammad Ali Mohseni-Bandpei; Masoomeh Nakhaee; Mohammad Ebrahim Mousavi; Ali Shakourirad; Mohammad Reza Safari; Reza Vahab Kashani Journal: Ultrasound Med Biol Date: 2014-05-03 Impact factor: 2.998
Authors: Fabio Sarto; Jörg Spörri; Daniel P Fitze; Jonathan I Quinlan; Marco V Narici; Martino V Franchi Journal: Sports Med Date: 2021-03-08 Impact factor: 11.136
Authors: Alberto Rubio-Peirotén; Felipe García-Pinillos; Diego Jaén-Carrillo; Antonio Cartón-Llorente; Luis E Roche-Seruendo Journal: Int J Environ Res Public Health Date: 2021-02-18 Impact factor: 3.390
Authors: Dallin C Swanson; Joshua K Sponbeck; Derek A Swanson; Conner D Stevens; Steven P Allen; Ulrike H Mitchell; James D George; Aaron Wayne Johnson Journal: BMC Musculoskelet Disord Date: 2022-02-14 Impact factor: 2.362
Authors: Daniel M Cushman; Ziva Petrin; Sarah Eby; Nathan D Clements; Peter Haight; Brian Snitily; Masaru Teramoto Journal: Phys Sportsmed Date: 2020-11-26 Impact factor: 2.241
Authors: Eleuterio A Sánchez Romero; Joel Pollet; Sebastián Martín Pérez; José Luis Alonso Pérez; Alberto Carlos Muñoz Fernández; Paolo Pedersini; Carlos Barragán Carballar; Jorge Hugo Villafañe Journal: Medicina (Kaunas) Date: 2020-07-28 Impact factor: 2.430