Literature DB >> 28717569

Histogram analysis for smartphone-based rapid hematocrit determination.

Uddin M Jalal1, Sang C Kim1, Joon S Shim1.   

Abstract

A novel and rapid analysis technique using histogram has been proposed for the colorimetric quantification of blood hematocrits. A smartphone-based "Histogram" app for the detection of hematocrits has been developed integrating the smartphone embedded camera with a microfluidic chip via a custom-made optical platform. The developed histogram analysis shows its effectiveness in the automatic detection of sample channel including auto-calibration and can analyze the single-channel as well as multi-channel images. Furthermore, the analyzing method is advantageous to the quantification of blood-hematocrit both in the equal and varying optical conditions. The rapid determination of blood hematocrits carries enormous information regarding physiological disorders, and the use of such reproducible, cost-effective, and standard techniques may effectively help with the diagnosis and prevention of a number of human diseases.

Entities:  

Keywords:  (040.1880) Detection; (100.2960) Image analysis; (110.0110) Imaging systems; (170.1610) Clinical applications; (170.3880) Medical and biological imaging

Year:  2017        PMID: 28717569      PMCID: PMC5508830          DOI: 10.1364/BOE.8.003317

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  29 in total

1.  Transport in two-dimensional paper networks.

Authors:  Elain Fu; Stephen A Ramsey; Peter Kauffman; Barry Lutz; Paul Yager
Journal:  Microfluid Nanofluidics       Date:  2011-01       Impact factor: 2.529

2.  Sub-femtomole detection of 16s rRNA from Legionella pneumophila using surface plasmon resonance imaging.

Authors:  Amir M Foudeh; Jamal T Daoud; Sebastien P Faucher; Teodor Veres; Maryam Tabrizian
Journal:  Biosens Bioelectron       Date:  2013-08-28       Impact factor: 10.618

Review 3.  The Normal Haematocrit Trial in dialysis patients with cardiac disease: are we any the less confused about target haemoglobin?

Authors:  I C Macdougall; E Ritz
Journal:  Nephrol Dial Transplant       Date:  1998-12       Impact factor: 5.992

4.  Label-free biodetection using a smartphone.

Authors:  Dustin Gallegos; Kenneth D Long; Hojeong Yu; Peter P Clark; Yixiao Lin; Sherine George; Pabitra Nath; Brian T Cunningham
Journal:  Lab Chip       Date:  2013-06-07       Impact factor: 6.799

5.  Development of a paper-based analytical device for colorimetric detection of select foodborne pathogens.

Authors:  Jana C Jokerst; Jaclyn A Adkins; Bledar Bisha; Mallory M Mentele; Lawrence D Goodridge; Charles S Henry
Journal:  Anal Chem       Date:  2012-03-06       Impact factor: 6.986

6.  Biosensing using straight long-range surface plasmon waveguides.

Authors:  Oleksiy Krupin; Hamoudi Asiri; Chen Wang; R Niall Tait; Pierre Berini
Journal:  Opt Express       Date:  2013-01-14       Impact factor: 3.894

7.  Optical systems for point-of-care diagnostic instrumentation: analysis of imaging performance and cost.

Authors:  Mark C Pierce; Shannon E Weigum; Jacob M Jaslove; Rebecca Richards-Kortum; Tomasz S Tkaczyk
Journal:  Ann Biomed Eng       Date:  2013-10-05       Impact factor: 3.934

8.  Synthesis of biomimetic oxygen-carrying compartmentalized microparticles using flow lithography.

Authors:  Harry Z An; Eric R Safai; H Burak Eral; Patrick S Doyle
Journal:  Lab Chip       Date:  2013-12-21       Impact factor: 6.799

9.  Optofluidic imaging: now and beyond.

Authors:  Yanhui Zhao; Zackary S Stratton; Feng Guo; Michael Ian Lapsley; Chung Yu Chan; Sz-Chin Steven Lin; Tony Jun Huang
Journal:  Lab Chip       Date:  2012-11-09       Impact factor: 6.799

10.  Red blood cell transfusion in the critically ill patient.

Authors:  Christophe Lelubre; Jean-Louis Vincent
Journal:  Ann Intensive Care       Date:  2011-10-04       Impact factor: 6.925

View more
  6 in total

1.  Microfluidic-Based Novel Optical Quantification of Red Blood Cell Concentration in Blood Flow.

Authors:  Yudong Wang; Bharath Babu Nunna; Niladri Talukder; Eon Soo Lee
Journal:  Bioengineering (Basel)       Date:  2022-06-08

2.  Back to the "Gold Standard": How Precise is Hematocrit Detection Today?

Authors:  Leonid Livshits; Tal Bilu; Sari Peretz; Anna Bogdanova; Max Gassmann; Harel Eitam; Ariel Koren; Carina Levin
Journal:  Mediterr J Hematol Infect Dis       Date:  2022-07-01       Impact factor: 3.122

3.  A Disposable Blood-on-a-Chip for Simultaneous Measurement of Multiple Biophysical Properties.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2018-09-20       Impact factor: 2.891

4.  Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2019-08-30       Impact factor: 2.891

5.  Fully integrated rapid microfluidic device translated from conventional 96-well ELISA kit.

Authors:  M Jalal Uddin; Nabil H Bhuiyan; Joon S Shim
Journal:  Sci Rep       Date:  2021-01-21       Impact factor: 4.379

6.  Microfluidic Point-of-Care Devices: New Trends and Future Prospects for eHealth Diagnostics.

Authors:  Jorge Ricardo Mejía-Salazar; Kamilla Rodrigues Cruz; Elsa María Materón Vásques; Osvaldo Novais de Oliveira
Journal:  Sensors (Basel)       Date:  2020-03-31       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.