Literature DB >> 33479284

Fully integrated rapid microfluidic device translated from conventional 96-well ELISA kit.

M Jalal Uddin1,2, Nabil H Bhuiyan1, Joon S Shim3,4.   

Abstract

In this work, a fully integrated active microfluidic device transforming a conventional 96-well kit into point-of-care testing (POCT) device was implemented to improve the performance of traditional enzyme-linked immunosorbent assay (ELISA). ELISA test by the conventional method often requires the collection of 96 samples for its operation as well as longer incubation time from hours to overnight, whereas our proposed device conducts ELISA immediately individualizing a 96-well for individual patients. To do that, a programmable and disposable on-chip pump and valve were integrated on the device for precise control and actuation of microfluidic reagents, which regulated a reaction time and reagent volume to support the optimized protocols of ELISA. Due to the on-chip pump and valve, ELISA could be executed with reduced consumption of reagents and shortening the assay time, which are crucial for conventional ELISA using 96-well microplate. To demonstrate highly sensitive detection and easy-to-use operation, this unconventional device was successfully applied for the quantification of cardiac troponin I (cTnI) of 4.88 pg/mL using a minimum sample volume of 30 µL with a shorter assay time of 15 min for each ELISA step. The limit of detection (LOD) thus obtained was significantly improved than the conventional 96-well platform.

Entities:  

Year:  2021        PMID: 33479284      PMCID: PMC7820004          DOI: 10.1038/s41598-021-81433-y

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  20 in total

Review 1.  Advances in paper-based point-of-care diagnostics.

Authors:  Jie Hu; ShuQi Wang; Lin Wang; Fei Li; Belinda Pingguan-Murphy; Tian Jian Lu; Feng Xu
Journal:  Biosens Bioelectron       Date:  2013-11-19       Impact factor: 10.618

Review 2.  Assay formats: Recommendation for best practices and harmonization from the global bioanalysis consortium harmonization team.

Authors:  Sherri Dudal; Daniel Baltrukonis; Rebecca Crisino; M Jaya Goyal; Alison Joyce; Karolina Osterlund; John Smeraglia; Yoshitaka Taniguchi; Jihong Yang
Journal:  AAPS J       Date:  2013-12-17       Impact factor: 4.009

Review 3.  Diagnosing infections--current and anticipated technologies for point-of-care diagnostics and home-based testing.

Authors:  L Bissonnette; M G Bergeron
Journal:  Clin Microbiol Infect       Date:  2010-08       Impact factor: 8.067

Review 4.  Point of care testing: The impact of nanotechnology.

Authors:  Leila Syedmoradi; Maryam Daneshpour; Mehrdad Alvandipour; Frank A Gomez; Hassan Hajghassem; Kobra Omidfar
Journal:  Biosens Bioelectron       Date:  2016-08-26       Impact factor: 10.618

5.  On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains.

Authors:  Uddin M Jalal; Gyeong Jun Jin; Kyu Shik Eom; Min Ho Kim; Joon S Shim
Journal:  Bioelectrochemistry       Date:  2017-11-06       Impact factor: 5.373

Review 6.  Microfluidics Based Point-of-Care Diagnostics.

Authors:  Chandra M Pandey; Shine Augustine; Saurabh Kumar; Suveen Kumar; Sharda Nara; Saurabh Srivastava; Bansi D Malhotra
Journal:  Biotechnol J       Date:  2017-12-18       Impact factor: 4.677

7.  Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine.

Authors:  Uddin M Jalal; Gyeong Jun Jin; Joon S Shim
Journal:  Anal Chem       Date:  2017-11-28       Impact factor: 6.986

8.  A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I.

Authors:  Dong Hwan Choi; Seok Ki Lee; Young Kyoung Oh; Byeong Woo Bae; Sung Dong Lee; Sanghyo Kim; Yong-Beom Shin; Min-Gon Kim
Journal:  Biosens Bioelectron       Date:  2010-01-25       Impact factor: 10.618

Review 9.  Nano/Microfluidics for diagnosis of infectious diseases in developing countries.

Authors:  Won Gu Lee; Yun-Gon Kim; Bong Geun Chung; Utkan Demirci; Ali Khademhosseini
Journal:  Adv Drug Deliv Rev       Date:  2009-11-30       Impact factor: 15.470

Review 10.  Point-of-Care Diagnostics: Recent Developments in a Connected Age.

Authors:  Samiksha Nayak; Nicole R Blumenfeld; Tassaneewan Laksanasopin; Samuel K Sia
Journal:  Anal Chem       Date:  2016-12-13       Impact factor: 6.986

View more
  3 in total

Review 1.  Microfluidic Point-of-Care (POC) Devices in Early Diagnosis: A Review of Opportunities and Challenges.

Authors:  Shih-Mo Yang; Shuangsong Lv; Wenjun Zhang; Yubao Cui
Journal:  Sensors (Basel)       Date:  2022-02-18       Impact factor: 3.576

2.  An Internet-of-Disease System for COVID-19 Testing Using Saliva by an AI-Controlled Microfluidic ELISA Device.

Authors:  Nabil Hossain Bhuiyan; Md Jalal Uddin; Joowon Lee; Jun Hyeok Hong; Joon Sub Shim
Journal:  Adv Mater Technol       Date:  2022-07-15

Review 3.  Pushing the detection limits: strategies towards highly sensitive optical-based protein detection.

Authors:  Nikan Momenbeitollahi; Teran Cloet; Huiyan Li
Journal:  Anal Bioanal Chem       Date:  2021-08-06       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.