Literature DB >> 28700425

Ultrastaging of Sentinel Lymph Nodes in Endometrial Carcinoma According to Use of 2 Different Methods.

Elizabeth Euscher1, Dawen Sui, Pamela Soliman, Shannon Westin, Preetha Ramalingam, Roland Bassett, Anais Malpica.   

Abstract

Sentinel lymph node (SLN) sampling may provide staging information without exposing patients to risks of lymph node dissection. There is no consensus protocol for optimal pathologic handling of these specimens. This study compares 2 ultrastaging protocols of SLN in endometrial carcinoma (EC). All SLN were serially sectioned perpendicular to the long axis in 2 mm intervals and entirely submitted for routine hematoxylin and eosin (H&E) processing. SLN negative by routine processing had ultrastaging (US) by one of the following: method 1 (M1), 5 H&E levels at 250 μm intervals with 2 unstained slides at each level; pankeratin immunohistochemistry (IHC) performed on level 1 in cases with negative H&E levels or method 2 (M2), 1 H&E level + 2 unstained slides cut 250 μm into the tissue block; pankeratin IHC performed in cases with negative H&E. Histologic subtype, numbers of SLN, positive SLN, non-SLN, positive non-SLN, and metastasis size were recorded. A total of 178 patients had 527 SLNs (1-16 per case; median, 2 SLN) sampled during hysterectomy for the following EC histotypes: endometrioid International Federation of Gynecology and Obstetrics grade 1/2, 117 (66%); endometrioid International Federation of Gynecology and Obstetrics grade 3, 18 (10%); serous, 20 (11%); carcinosarcoma, 11 (6%); clear cell, 9 (5%); and undifferentiated, 3 (2%). In all, 172 patients had ultrastaging: M1=65; M2=58. In total, 33 patients were SLN positive. Twenty-seven had SLN submitted for US: M1=11; M2=16. Eleven patients had additional SLN detected by US: M1=5; M2=6. Of these, 8 were patients whose SLN were only detected by US representing an increase of 32% in number of patients with positive SLN. Six patients (M1=2; M2=4) with negative SLN had a positive non-SLN. Mean size of ultrastage-detected metastasis was 0.24 mm for M1 and 0.38 mm for M2. Statistical analysis comparing M1 and M2 detected no statistically significant associations with respect to number of positive SLN detected, size of metastasis or false-negative rate and method. The methods performed similarly for both low-grade and high-grade EC. A more comprehensive US protocol had no significant advantages over a single wide interval and IHC in this study population. A pankeratin IHC stain enhances metastasis detection. Additional studies are required to further test this limited protocol as well as to evaluate the clinical significance of the low volume disease detected by ultrastaging.

Entities:  

Mesh:

Year:  2018        PMID: 28700425     DOI: 10.1097/PGP.0000000000000415

Source DB:  PubMed          Journal:  Int J Gynecol Pathol        ISSN: 0277-1691            Impact factor:   2.762


  5 in total

1.  ESGO/ESTRO/ESP Guidelines for the management of patients with endometrial carcinoma.

Authors:  Nicole Concin; Carien L Creutzberg; Ignace Vergote; David Cibula; Mansoor Raza Mirza; Simone Marnitz; Jonathan A Ledermann; Tjalling Bosse; Cyrus Chargari; Anna Fagotti; Christina Fotopoulou; Antonio González-Martín; Sigurd F Lax; Domenica Lorusso; Christian Marth; Philippe Morice; Remi A Nout; Dearbhaile E O'Donnell; Denis Querleu; Maria Rosaria Raspollini; Jalid Sehouli; Alina E Sturdza; Alexandra Taylor; Anneke M Westermann; Pauline Wimberger; Nicoletta Colombo; François Planchamp; Xavier Matias-Guiu
Journal:  Virchows Arch       Date:  2021-02       Impact factor: 4.064

2.  Clinicopathologic and Genomic Analysis of TP53-Mutated Endometrial Carcinomas.

Authors:  Lora H Ellenson; Britta Weigelt; Robert A Soslow; Amir Momeni-Boroujeni; Wissam Dahoud; Chad M Vanderbilt; Sarah Chiang; Rajmohan Murali; Eric V Rios-Doria; Kaled M Alektiar; Carol Aghajanian; Nadeem R Abu-Rustum; Marc Ladanyi
Journal:  Clin Cancer Res       Date:  2021-02-18       Impact factor: 12.531

3.  Pathological processing of sentinel lymph nodes in endometrial carcinoma - routine aspects of grossing, ultra-staging, and surgico-pathological parameters in a series of 833 lymph nodes.

Authors:  Tilman T Rau; Mona V Deppeler; Lucine Christe; Franziska Siegenthaler; Sara Imboden; Andrea Papadia; Michael D Mueller
Journal:  Virchows Arch       Date:  2022-07-19       Impact factor: 4.535

Review 4.  Sentinel Lymph Node Mapping in Endometrial Cancer: A Comprehensive Review.

Authors:  Lirong Zhai; Xiwen Zhang; Manhua Cui; Jianliu Wang
Journal:  Front Oncol       Date:  2021-06-29       Impact factor: 6.244

Review 5.  Sentinel lymph node biopsy in endometrial cancer: state of the art.

Authors:  Luigi Della Corte; Pierluigi Giampaolino; Antonio Mercorio; Gaetano Riemma; Antonio Schiattarella; Pasquale De Franciscis; Giuseppe Bifulco
Journal:  Transl Cancer Res       Date:  2020-12       Impact factor: 1.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.