Quantifying Baseline Fixed Charge Density in Healthy Human Cartilage Endplate: A Two-point Electrical Conductivity Method.

Yongren Wu1,2, Sarah E Cisewski1, Yi Sun1, Brooke J Damon1, Barton L Sachs2, Vincent D Pellegrini2, Elizabeth H Slate3, Hai Yao1,2.   

Abstract

STUDY
DESIGN: Regional measurements of fixed charge densities (FCDs) of healthy human cartilage endplate (CEP) using a two-point electrical conductivity approach.
OBJECTIVE: The aim of this study was to determine the FCDs at four different regions (central, lateral, anterior, and posterior) of human CEP, and correlate the FCDs with tissue biochemical composition. SUMMARY OF BACKGROUND DATA: The CEP, a thin layer of hyaline cartilage on the cranial and caudal surfaces of the intervertebral disc, plays an irreplaceable role in maintaining the unique physiological mechano-electrochemical environment inside the disc. FCD, arising from the carboxyl and sulfate groups of the glycosaminoglycans (GAG) in the extracellular matrix of the disc, is a key regulator of the disc ionic and osmotic environment through physicochemical and electrokinetic effects. Although FCDs in the annulus fibrosus (AF) and nucleus pulposus (NP) have been reported, quantitative baseline FCD in healthy human CEP has not been reported.
METHODS: CEP specimens were regionally isolated from human lumbar spines. FCD and ion diffusivity were concurrently investigated using a two-point electrical conductivity method. Biochemical assays were used to quantify regional GAG and water content.
RESULTS: FCD in healthy human CEP was region-dependent, with FCD lowest in the lateral region (P = 0.044). Cross-region FCD was 30% to 60% smaller than FCD in NP, but similar to the AF and articular cartilage (AC). CEP FCD (average: 0.12 ± 0.03 mEq/g wet tissue) was correlated with GAG content (average: 31.24 ± 5.06 μg/mg wet tissue) (P = 0.005). In addition, the cross-region ion diffusivity in healthy CEP (2.97 ± 1.00 × 10 cm/s) was much smaller than the AF and NP.
CONCLUSION: Healthy human CEP acts as a biomechanical interface, distributing loads between the bony vertebral body and soft disc tissues and as a gateway impeding rapid solute diffusion through the disc. LEVEL OF EVIDENCE: N/A.

Entities:  

Mesh:

Year:  2017        PMID: 28699925      PMCID: PMC5509527          DOI: 10.1097/BRS.0000000000002061

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.241


  41 in total

1.  Swelling pressure of the lumbar intervertebral discs: influence of age, spinal level, composition, and degeneration.

Authors:  J P Urban; J F McMullin
Journal:  Spine (Phila Pa 1976)       Date:  1988-02       Impact factor: 3.468

2.  A simple physicochemical micromethod for determining fixed anionic groups in connective tissue.

Authors:  A Maroudas; H Thomas
Journal:  Biochim Biophys Acta       Date:  1970-07-21

3.  Swelling of the intervertebral disc in vitro.

Authors:  J P Urban; A Maroudas
Journal:  Connect Tissue Res       Date:  1981       Impact factor: 3.417

4.  1980 Volvo award winner in basic science. Nutritional pathways of the intervertebral disc. An experimental study using hydrogen washout technique.

Authors:  K Ogata; L A Whiteside
Journal:  Spine (Phila Pa 1976)       Date:  1981 May-Jun       Impact factor: 3.468

5.  Electrical conductivity of lumbar anulus fibrosis: effects of porosity and fixed charge density.

Authors:  Wei Yong Gu; Marc-Antoine Justiz; Hai Yao
Journal:  Spine (Phila Pa 1976)       Date:  2002-11-01       Impact factor: 3.468

6.  Effect of endplate calcification and mechanical deformation on the distribution of glucose in intervertebral disc: a 3D finite element study.

Authors:  Alicia R Jackson; Chun-Yuh Huang; Wei Yong Gu
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-02       Impact factor: 1.763

7.  Angiogenesis and inflammatory cell infiltration in lumbar disc herniation.

Authors:  Yoichi Koike; Miwa Uzuki; Shoichi Kokubun; Takashi Sawai
Journal:  Spine (Phila Pa 1976)       Date:  2003-09-01       Impact factor: 3.468

8.  Indentation determined mechanoelectrochemical properties and fixed charge density of articular cartilage.

Authors:  X Lux Lu; Daniel D N Sun; X Edward Guo; Faye H Chen; W Michael Lai; Van C Mow
Journal:  Ann Biomed Eng       Date:  2004-03       Impact factor: 3.934

9.  Innervation of pathologies in the lumbar vertebral end plate and intervertebral disc.

Authors:  Aaron J Fields; Ellen C Liebenberg; Jeffrey C Lotz
Journal:  Spine J       Date:  2013-10-18       Impact factor: 4.166

10.  Influence of biochemical composition on endplate cartilage tensile properties in the human lumbar spine.

Authors:  Aaron J Fields; David Rodriguez; Kaitlyn N Gary; Ellen C Liebenberg; Jeffrey C Lotz
Journal:  J Orthop Res       Date:  2013-11-23       Impact factor: 3.494

View more
  2 in total

1.  Electrical Conductivity Method to Determine Sexual Dimorphisms in Human Temporomandibular Disc Fixed Charge Density.

Authors:  Gregory J Wright; Matthew C Coombs; Yongren Wu; Brooke J Damon; Thierry H Bacro; Michael J Kern; Xiaojing Chen; Hai Yao
Journal:  Ann Biomed Eng       Date:  2017-11-27       Impact factor: 3.934

2.  Shear strain and inflammation-induced fixed charge density loss in the knee joint cartilage following ACL injury and reconstruction: A computational study.

Authors:  Gustavo A Orozco; Atte S A Eskelinen; Joonas P Kosonen; Matthew S Tanaka; Mingrui Yang; Thomas M Link; Benjamin Ma; Xiaojuan Li; Alan J Grodzinsky; Rami K Korhonen; Petri Tanska
Journal:  J Orthop Res       Date:  2021-10-01       Impact factor: 3.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.