Literature DB >> 24273192

Influence of biochemical composition on endplate cartilage tensile properties in the human lumbar spine.

Aaron J Fields1, David Rodriguez, Kaitlyn N Gary, Ellen C Liebenberg, Jeffrey C Lotz.   

Abstract

Endplate cartilage integrity is critical to spine health and is presumably impaired by deterioration in biochemical composition. Yet, quantitative relationships between endplate biochemical composition and biomechanical properties are unavailable. Using endplate cartilage harvested from human lumbar spines (six donors, ages 51-67 years) we showed that endplate biochemical composition has a significant influence on its equilibrium tensile properties and that the presence of endplate damage associates with a diminished composition-function relationship. We found that the equilibrium tensile modulus (5.9 ± 5.7 MPa) correlated significantly with collagen content (559 ± 147 µg/mg dry weight, r(2)  = 0.35) and with the collagen/GAG ratio (6.0 ± 2.1, r(2)  = 0.58). Accounting for the damage status of the adjacent cartilage improved the latter correlation (r(2)  = 0.77) and indicated that samples with adjacent damage such as fissures and avulsions had a diminished modulus-collagen/GAG relationship (p = 0.02). Quasi-linear viscoelastic relaxation properties (C, t1 , and t2 ) did not correlate with biochemical composition. We conclude that reduced matrix quantity decreases the equilibrium tensile modulus of human endplate cartilage and that characteristics of biochemical composition that are independent of matrix quantity, that is, characteristics related to matrix quality, may also be important.
© 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  biomechanical properties; cartilage endplate; intervertebral disc degeneration; low back pain; spine

Mesh:

Substances:

Year:  2013        PMID: 24273192      PMCID: PMC4039641          DOI: 10.1002/jor.22516

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  45 in total

1.  An improved method to analyze the stress relaxation of ligaments following a finite ramp time based on the quasi-linear viscoelastic theory.

Authors:  Steven D Abramowitch; Savio L Woo
Journal:  J Biomech Eng       Date:  2004-02       Impact factor: 2.097

Review 2.  Nutrition of the intervertebral disc.

Authors:  Jill P G Urban; Stanton Smith; Jeremy C T Fairbank
Journal:  Spine (Phila Pa 1976)       Date:  2004-12-01       Impact factor: 3.468

3.  Evaluation of intervertebral disc cartilaginous endplate structure using magnetic resonance imaging.

Authors:  Sung M Moon; Jonathon H Yoder; Alexander C Wright; Lachlan J Smith; Edward J Vresilovic; Dawn M Elliott
Journal:  Eur Spine J       Date:  2013-05-15       Impact factor: 3.134

4.  Tumor necrosis factor-immunoreactive cells and PGP 9.5-immunoreactive nerve fibers in vertebral endplates of patients with discogenic low back Pain and Modic Type 1 or Type 2 changes on MRI.

Authors:  Seiji Ohtori; Gen Inoue; Toshinori Ito; Takana Koshi; Tomoyuki Ozawa; Hideo Doya; Tomoko Saito; Hideshige Moriya; Kazuhisa Takahashi
Journal:  Spine (Phila Pa 1976)       Date:  2006-04-20       Impact factor: 3.468

5.  Biochemical and structural properties of the cartilage end-plate and its relation to the intervertebral disc.

Authors:  S Roberts; J Menage; J P Urban
Journal:  Spine (Phila Pa 1976)       Date:  1989-02       Impact factor: 3.468

Review 6.  Altered mechanics of cartilage with osteoarthritis: human osteoarthritis and an experimental model of joint degeneration.

Authors:  L A Setton; D M Elliott; V C Mow
Journal:  Osteoarthritis Cartilage       Date:  1999-01       Impact factor: 6.576

7.  ISSLS prize winner: how loading rate influences disc failure mechanics: a microstructural assessment of internal disruption.

Authors:  Samuel P Veres; Peter A Robertson; Neil D Broom
Journal:  Spine (Phila Pa 1976)       Date:  2010-10-01       Impact factor: 3.468

8.  The prevalence of MRI-defined spinal pathoanatomies and their association with modic changes in individuals seeking care for low back pain.

Authors:  Hanne B Albert; Andrew M Briggs; Peter Kent; Andreas Byrhagen; Christian Hansen; Karina Kjaergaard
Journal:  Eur Spine J       Date:  2011-05-05       Impact factor: 3.134

9.  Ultrashort time-to-echo MRI of the cartilaginous endplate: technique and association with intervertebral disc degeneration.

Authors:  Travis Law; Marina-Portia Anthony; Queenie Chan; Dino Samartzis; Mina Kim; Kenneth M C Cheung; Pek-Lan Khong
Journal:  J Med Imaging Radiat Oncol       Date:  2013-03-26       Impact factor: 1.735

10.  Determination of collagen fibril orientation in the cartilage of vertebral end plate.

Authors:  R M Aspden; D S Hickey; D W Hukins
Journal:  Connect Tissue Res       Date:  1981       Impact factor: 3.417

View more
  19 in total

1.  Effects of dynamic loading on solute transport through the human cartilage endplate.

Authors:  Sara L Sampson; Meghan Sylvia; Aaron J Fields
Journal:  J Biomech       Date:  2018-12-08       Impact factor: 2.712

2.  Human cartilage endplate permeability varies with degeneration and intervertebral disc site.

Authors:  John F DeLucca; Daniel H Cortes; Nathan T Jacobs; Edward J Vresilovic; Randall L Duncan; Dawn M Elliott
Journal:  J Biomech       Date:  2016-01-14       Impact factor: 2.712

3.  MRI quantification of human spine cartilage endplate geometry: Comparison with age, degeneration, level, and disc geometry.

Authors:  John F DeLucca; John M Peloquin; Lachlan J Smith; Alexander C Wright; Edward J Vresilovic; Dawn M Elliott
Journal:  J Orthop Res       Date:  2016-06-19       Impact factor: 3.494

4.  The region-dependent biomechanical and biochemical properties of bovine cartilaginous endplate.

Authors:  Yongren Wu; Sarah E Cisewski; Barton L Sachs; Vincent D Pellegrini; Michael J Kern; Elizabeth H Slate; Hai Yao
Journal:  J Biomech       Date:  2015-07-10       Impact factor: 2.712

5.  Nutrient supply and nucleus pulposus cell function: effects of the transport properties of the cartilage endplate and potential implications for intradiscal biologic therapy.

Authors:  J Wong; S L Sampson; H Bell-Briones; A Ouyang; A A Lazar; J C Lotz; A J Fields
Journal:  Osteoarthritis Cartilage       Date:  2019-02-02       Impact factor: 6.576

Review 6.  Novel diagnostic and prognostic methods for disc degeneration and low back pain.

Authors:  Dino Samartzis; Ari Borthakur; Inna Belfer; Cora Bow; Jeffrey C Lotz; Hai-Qiang Wang; Kenneth M C Cheung; Eugene Carragee; Jaro Karppinen
Journal:  Spine J       Date:  2015-09-01       Impact factor: 4.166

7.  Region and strain-dependent diffusivities of glucose and lactate in healthy human cartilage endplate.

Authors:  Yongren Wu; Sarah E Cisewski; Nicholas Wegner; Shichang Zhao; Vincent D Pellegrini; Elizabeth H Slate; Hai Yao
Journal:  J Biomech       Date:  2016-06-15       Impact factor: 2.712

8.  Cartilaginous end plates: Quantitative MR imaging with very short echo times-orientation dependence and correlation with biochemical composition.

Authors:  Aaron J Fields; Misung Han; Roland Krug; Jeffrey C Lotz
Journal:  Radiology       Date:  2014-10-10       Impact factor: 11.105

9.  Contribution of the endplates to disc degeneration.

Authors:  Aaron J Fields; Alexander Ballatori; Ellen C Liebenberg; Jeffrey C Lotz
Journal:  Curr Mol Biol Rep       Date:  2018-09-20

Review 10.  Intervertebral disc degeneration and regeneration: a motion segment perspective.

Authors:  B Ashinsky; H E Smith; R L Mauck; S E Gullbrand
Journal:  Eur Cell Mater       Date:  2021-03-24       Impact factor: 3.942

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.