Literature DB >> 28690710

The Role of Simulation in the Design of a Semi-Enclosed Tubular Embolus Retrieval.

Xuelian Gu1, Yongxiang Qi2, Arthur Erdman3, Zhonghua Li2.   

Abstract

A numerical analysis of a semi-enclosed tubular mechanical embolus retrieval device (MERD) for the treatment of acute ischemic stroke (AIS) is presented. In this research, the finite element analysis (FEA) methodology is used to evaluate mechanical performance and provide suggestions for optimizing the geometric design. A MERD fabricated from nickel-titanium alloy (Nitinol) tubing is simulated and analyzed under complex in vivo loading conditions involving shape-setting, crimping, deployment, and embolus retrieval. As a result, the peak strain of the shape-setting procedure is proved to be safe for the device pattern. However, the MERD shows poor mechanical behavior after crimping into a catheter, because the peak crimping strain obtains a value of 12.1%. The delivery and deployment step demonstrates that the artery wall has little risk of serious injuries or rupture. In addition, the process of simulation of embolus retrieval and device system migration inside the cerebral artery lumen provides useful information during the design process.

Entities:  

Keywords:  Nitinol; acute ischemic stroke; biomechanics; embolus retrieval; finite element analysis

Year:  2017        PMID: 28690710      PMCID: PMC5472853          DOI: 10.1115/1.4036286

Source DB:  PubMed          Journal:  J Med Device        ISSN: 1932-6181            Impact factor:   0.582


  9 in total

1.  Mechanical analysis of a prototype of small diameter vascular prosthesis: numerical simulations.

Authors:  M Zidi; M Cheref
Journal:  Comput Biol Med       Date:  2003-01       Impact factor: 4.589

2.  Comparing coronary stent material performance on a common geometric platform through simulated bench testing.

Authors:  J A Grogan; S B Leen; P E McHugh
Journal:  J Mech Behav Biomed Mater       Date:  2012-03-03

3.  Realistic finite element-based stent design: the impact of balloon folding.

Authors:  Matthieu De Beule; Peter Mortier; Stéphane G Carlier; Benedict Verhegghe; Rudy Van Impe; Pascal Verdonck
Journal:  J Biomech       Date:  2007-10-24       Impact factor: 2.712

4.  A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise].

Authors:  O Krischek; E Miloslavski; S Fischer; S Shrivastava; H Henkes
Journal:  Minim Invasive Neurosurg       Date:  2011-04-19

5.  Prognostic factors related to clinical outcome following thrombectomy in ischemic stroke (RECOST study). 50 patients prospective study.

Authors:  V Costalat; K Lobotesis; P Machi; I Mourand; I Maldonado; C Heroum; J F Vendrell; D Milhaud; C Riquelme; A Bonafé; C Arquizan
Journal:  Eur J Radiol       Date:  2012-08-30       Impact factor: 3.528

6.  Impact of plaque haemorrhage and its age on structural stresses in atherosclerotic plaques of patients with carotid artery disease: an MR imaging-based finite element simulation study.

Authors:  Umar Sadat; Zhongzhao Teng; Victoria E Young; Chengcheng Zhu; Tjun Y Tang; Martin J Graves; Jonathan H Gillard
Journal:  Int J Cardiovasc Imaging       Date:  2010-08-11       Impact factor: 2.357

7.  Percutaneous mechanical thrombectomy combined with catheter-directed thrombolysis in the treatment of symptomatic lower extremity deep venous thrombosis.

Authors:  Hong-Jian Shi; You-Hua Huang; Tao Shen; Qiang Xu
Journal:  Eur J Radiol       Date:  2008-06-03       Impact factor: 3.528

8.  The Penumbra System: a mechanical device for the treatment of acute stroke due to thromboembolism.

Authors:  A Bose; H Henkes; K Alfke; W Reith; T E Mayer; A Berlis; V Branca; S Po Sit
Journal:  AJNR Am J Neuroradiol       Date:  2008-05-22       Impact factor: 3.825

9.  Computational mechanics of Nitinol stent grafts.

Authors:  C Kleinstreuer; Z Li; C A Basciano; S Seelecke; M A Farber
Journal:  J Biomech       Date:  2008-07-17       Impact factor: 2.712

  9 in total
  2 in total

1.  Realistic computer modelling of stent retriever thrombectomy: a hybrid finite-element analysis-smoothed particle hydrodynamics model.

Authors:  S Mostafa Mousavi J S; Danial Faghihi; Kelsey Sommer; Mohammad M S Bhurwani; Tatsat R Patel; Briana Santo; Muhammad Waqas; Ciprian Ionita; Elad I Levy; Adnan H Siddiqui; Vincent M Tutino
Journal:  J R Soc Interface       Date:  2021-12-15       Impact factor: 4.118

2.  The Wall Apposition Evaluation for a Mechanical Embolus Retrieval Device.

Authors:  Xuelian Gu; Yongxiang Qi; Arthur G Erdman
Journal:  J Healthc Eng       Date:  2018-09-25       Impact factor: 2.682

  2 in total