137Cs transmission imaging and segmented attenuation corrections in a small animal PET scanner.

Ying-Hwey Nai1,2, Takayuki Ose3, Miho Shidahara4, Hiroshi Watabe5,6.   

Abstract

Attenuation correction (AC) is required for accurate quantitative evaluation of small animal PET data. Our objective was to compare three AC methods in the small animal Clairvivo-PET scanner. The three AC methods involve applying attenuation coefficient maps generated by simulating a cylindrical map (SAC), segmenting the emission data (ESAC), and segmenting the transmission data (TSAC), imaged using a 137Cs single-photon source. Investigation was carried out using a 65 mm uniform cylinder and an NEMA NU4 2008 mouse phantom, filled with water or tungsten liquid, to mimic bone. Evaluation was carried out using the difference of the segmented map volume from the known cylindrical phantom volume, the recovery of the radioactivity concentration, and the line profiles. The optimal transmission scan time for achieving accurate AC using TSAC was determined using 5, 10, 15, 20, and 25 min transmission scan time. The effects of scatter correction and reconstruction algorithms on ESAC were investigated. SAC showed the best performance but was unable to correct for different tissues and the scanner bed, and faced difficulty with correct positioning of the attenuation coefficient map. ESAC was affected by scatter correction and reconstruction algorithm, and may result in poor boundary delineation, and hence was unreliable. TSAC showed reasonable performance but required further optimization of the default segmentation setting. A minimum transmission scan time of 20 min is recommended for Clairvivo-PET using 137Cs source to ensure that sufficient transmission counts are obtained to generate accurate attenuation coefficient map.

Entities:  

Keywords:  Attenuation correction; Positron emission tomography (PET); Segmented map; Small animal imaging; Transmission imaging

Mesh:

Substances:

Year:  2017        PMID: 28689313     DOI: 10.1007/s12194-017-0407-4

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  13 in total

1.  AMIDE: a free software tool for multimodality medical image analysis.

Authors:  Andreas Markus Loening; Sanjiv Sam Gambhir
Journal:  Mol Imaging       Date:  2003-07       Impact factor: 4.488

2.  Non-stationary convolution subtraction scatter correction with a dual-exponential scatter kernel for the Hamamatsu SHR-7700 animal PET scanner.

Authors:  Mark Lubberink; Tsuyoshi Kosugi; Harald Schneider; Hiroyuki Ohba; Mats Bergström
Journal:  Phys Med Biol       Date:  2004-03-07       Impact factor: 3.609

3.  Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards.

Authors:  K Sato; M Shidahara; H Watabe; S Watanuki; Y Ishikawa; Y Arakawa; Y H Nai; S Furumoto; M Tashiro; T Shoji; K Yanai; K Gonda
Journal:  Phys Med Biol       Date:  2015-12-30       Impact factor: 3.609

4.  Attenuation correction for small animal PET tomographs.

Authors:  Patrick L Chow; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner.

Authors:  Wencke Lehnert; Steven R Meikle; Stefan Siegel; Danny Newport; Richard B Banati; Anatoly B Rosenfeld
Journal:  Phys Med Biol       Date:  2006-08-02       Impact factor: 3.609

6.  Exact and approximate rebinning algorithms for 3-D PET data.

Authors:  M Defrise; P E Kinahan; D W Townsend; C Michel; M Sibomana; D F Newport
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

7.  Attenuation correction in PET using single photon transmission measurement.

Authors:  R A deKemp; C Nahmias
Journal:  Med Phys       Date:  1994-06       Impact factor: 4.071

8.  Performance evaluation of a high-sensitivity large-aperture small-animal PET scanner: ClairvivoPET.

Authors:  Tetsuro Mizuta; Keishi Kitamura; Hiroshi Iwata; Yoshiyuki Yamagishi; Atsushi Ohtani; Kazumi Tanaka; Yoshihiro Inoue
Journal:  Ann Nucl Med       Date:  2008-07-04       Impact factor: 2.668

9.  Importance of Attenuation Correction (AC) for Small Animal PET Imaging.

Authors:  Henrik H El Ali; Rasmus Poul Bodholdt; Jesper Tranekjær Jørgensen; Rebecca Myschetzky; Andreas Kjaer
Journal:  Diagnostics (Basel)       Date:  2012-10-09

10.  Attenuation correction for small animal PET images: a comparison of two methods.

Authors:  Daniela D'Ambrosio; Federico Zagni; Antonello E Spinelli; Mario Marengo
Journal:  Comput Math Methods Med       Date:  2013-04-16       Impact factor: 2.238

View more
  1 in total

1.  Non-invasive imaging of radiocesium dynamics in a living animal using a positron-emitting 127Cs tracer.

Authors:  Nobuo Suzui; Takuya Shibata; Yong-Gen Yin; Yoshihito Funaki; Keisuke Kurita; Hiroyuki Hoshina; Mitsutaka Yamaguchi; Shu Fujimaki; Noriaki Seko; Hiroshi Watabe; Naoki Kawachi
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.