Systemic arterial blood pH servocontrol of mechanical ventilation.

R L Coon, E J Zuperku, J P Kampine.   

Abstract

Servocontrol of mechanical ventilation using systemic arterial blood pH, measured by a dual-function pH/PCO2 intra-arterial sensor, as the controlled variable uas carried out in 30 dogs anesthetized with pentobarbital, 30 mg/kg. The control loop consisted of the animal, an intra-arterial dual-function pH/PCO2 sensor and sensor amplifier, a controller, and a Siemans-Elema 900 servoventilator. The system responded appropriately to changes in set-point pH from 7.30 to 7.50, as well as to infusions of lactic acid, which, with the control loop open, decreased systemic arterial blood pH 0.1 TO 0.2 PH units. Long-term (16 hr) ventilation of one dog with the systemic arterial blood pH servocontrol ventilator was shown to be feasible.

Entities:  

Mesh:

Year:  1978        PMID: 28683     DOI: 10.1097/00000542-197809000-00010

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  8 in total

1.  Closed-loop control for anesthesia breathing systems.

Authors:  D R Westenskow; C F Wallroth
Journal:  J Clin Monit       Date:  1990-07

Review 2.  Automatic control of mechanical ventilation. Part 1: theory and history of the technology.

Authors:  Fleur T Tehrani
Journal:  J Clin Monit Comput       Date:  2008-11-16       Impact factor: 2.502

Review 3.  Control of PaCO2 during mechanical ventilation: monitoring and feedback techniques.

Authors:  D R Westenskow
Journal:  Ann Biomed Eng       Date:  1981       Impact factor: 3.934

4.  The automatic selection of ventilation parameters during the initial phase of mechanical ventilation.

Authors:  T P Laubscher; A Frutiger; S Fanconi; J X Brunner
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

5.  A microprocessor based feedback controller for mechanical ventilation.

Authors:  K B Ohlson; D R Westenskow; W S Jordan
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

6.  A dual closed-loop control system for mechanical ventilation.

Authors:  Fleur Tehrani; Mark Rogers; Takkin Lo; Thomas Malinowski; Samuel Afuwape; Michael Lum; Brett Grundl; Michael Terry
Journal:  J Clin Monit Comput       Date:  2004-04       Impact factor: 2.502

7.  A feedback controller for ventilatory therapy.

Authors:  F W Chapman; J C Newell; R J Roy
Journal:  Ann Biomed Eng       Date:  1985       Impact factor: 3.934

Review 8.  The dawn of physiological closed-loop ventilation-a review.

Authors:  Philip von Platen; Anake Pomprapa; Burkhard Lachmann; Steffen Leonhardt
Journal:  Crit Care       Date:  2020-03-29       Impact factor: 9.097