OBJECTIVES: Distortion-product otoacoustic emissions (DPOAEs) are repeatable over time at lower frequencies (≤8 kHz) and higher frequencies (>8 kHz) in healthy, normal-hearing subjects. The purpose of this study was to examine the repeatability of DPOAEs measured with high-frequency (HF) stimuli in a patient population. It was hypothesized that HF DPOAEs would be repeatable over four trials. DESIGN: DPOAEs were measured in 40 cystic fibrosis (CF) patients (17 females and 23 males) with measurable behavioral thresholds and present DPOAEs for at least 2 of the high frequencies tested (8 to 16 kHz). A depth-compensated simulator sound pressure level (SPL) method of calibration was utilized. Each patient attended four trials, in which a complete set of data were collected. At each trial, three different DPOAE paradigms were completed. First, a discrete frequency sweep was measured between 8 and 16 kHz with a ratio (f2/f1) of 1.2 and levels of 65/50 dB SPL for L1/L2. Next, ratio and level sweeps were obtained at the two highest frequencies with a present DPOAE determined from the discrete frequency sweep, and the results were used to calculate DPOAE group delay and DPOAE detection thresholds, respectively. Ratio sweeps were collected with f2/f1 varied from 1.1 to 1.3 and stimulus levels of 60/45 dB SPL (L1/L2). Level sweeps were collected with an f2/f1 of 1.22 and L2 = 50 and L1 varied between 20 and 70 dB SPL. Differences and correlations between trials, SE of the measurement, and confidence intervals were calculated, as well as a repeated-measures analysis of variance. RESULTS: DPOAE response and behavioral threshold variability in CF patients were not significantly different across four trials. It can be expected in 95% of CF patients that differences between trials of DPOAE levels, group delay, and detection thresholds and behavioral thresholds are less than 6.26 dB, 0.87 msec, 9.34 dB, and 9.60 dB, respectively. CONCLUSIONS: HF DPOAEs were repeatable across four test trials for all three paradigms measured in a group of CF patients. These results are encouraging for the measurement of HF DPOAEs to be monitored in those exposed to ototoxic agents.
OBJECTIVES: Distortion-product otoacoustic emissions (DPOAEs) are repeatable over time at lower frequencies (≤8 kHz) and higher frequencies (>8 kHz) in healthy, normal-hearing subjects. The purpose of this study was to examine the repeatability of DPOAEs measured with high-frequency (HF) stimuli in a patient population. It was hypothesized that HF DPOAEs would be repeatable over four trials. DESIGN: DPOAEs were measured in 40 cystic fibrosis (CF) patients (17 females and 23 males) with measurable behavioral thresholds and present DPOAEs for at least 2 of the high frequencies tested (8 to 16 kHz). A depth-compensated simulator sound pressure level (SPL) method of calibration was utilized. Each patient attended four trials, in which a complete set of data were collected. At each trial, three different DPOAE paradigms were completed. First, a discrete frequency sweep was measured between 8 and 16 kHz with a ratio (f2/f1) of 1.2 and levels of 65/50 dB SPL for L1/L2. Next, ratio and level sweeps were obtained at the two highest frequencies with a present DPOAE determined from the discrete frequency sweep, and the results were used to calculate DPOAE group delay and DPOAE detection thresholds, respectively. Ratio sweeps were collected with f2/f1 varied from 1.1 to 1.3 and stimulus levels of 60/45 dB SPL (L1/L2). Level sweeps were collected with an f2/f1 of 1.22 and L2 = 50 and L1 varied between 20 and 70 dB SPL. Differences and correlations between trials, SE of the measurement, and confidence intervals were calculated, as well as a repeated-measures analysis of variance. RESULTS: DPOAE response and behavioral threshold variability in CFpatients were not significantly different across four trials. It can be expected in 95% of CFpatients that differences between trials of DPOAE levels, group delay, and detection thresholds and behavioral thresholds are less than 6.26 dB, 0.87 msec, 9.34 dB, and 9.60 dB, respectively. CONCLUSIONS: HF DPOAEs were repeatable across four test trials for all three paradigms measured in a group of CFpatients. These results are encouraging for the measurement of HF DPOAEs to be monitored in those exposed to ototoxic agents.
Authors: Angela C Garinis; Gayla L Poling; Ronald C Rubenstein; Dawn Konrad-Martin; Timothy E Hullar; David M Baguley; Holly L Burrows; Jennifer A Chisholm; Amy Custer; Laura Dreisbach Hawe; Lisa L Hunter; Theodore K Marras; Candice E Ortiz; Lucretia Petersen; Peter S Steyger; Kevin Winthrop; Erika M Zettner; Khaya Clark; Michelle Hungerford; Jay J Vachhani; Carmen C Brewer Journal: Am J Audiol Date: 2021-09-22 Impact factor: 1.636
Authors: Barna Budai; Péter Prekopp; László Noszek; Erika R Kovács; Márta Szőnyi; Dániel J Erdélyi; Krisztina Bíró; Lajos Géczi Journal: J Mol Med (Berl) Date: 2020-05-20 Impact factor: 4.599
Authors: W Wiktor Jedrzejczak; Edyta Pilka; Malgorzata Ganc; Krzysztof Kochanek; Henryk Skarzynski Journal: Int J Environ Res Public Health Date: 2022-02-14 Impact factor: 3.390