Literature DB >> 28676280

Evidence-based Criteria for Assessment of Visual Field Reliability.

Jithin Yohannan1, Jiangxia Wang1, Jamie Brown1, Balwantray C Chauhan2, Michael V Boland1, David S Friedman1, Pradeep Y Ramulu3.   

Abstract

PURPOSE: Assess the impact of false-positives (FP), false-negatives (FN), fixation losses (FL), and test duration (TD) on visual field (VF) reliability at different stages of glaucoma severity.
DESIGN: Retrospective. PARTICIPANTS: A total of 10 262 VFs from 1538 eyes of 909 subjects with suspect or manifest glaucoma and ≥5 VF examinations.
METHODS: Predicted mean deviation (MD) was calculated with multilevel modeling of longitudinal data. Differences between predicted and observed MD (ΔMD) were calculated as a reliability measure. The impact of FP, FN, FL, and TD on ΔMD was assessed using multilevel modeling. MAIN OUTCOME MEASURES: ΔMD associated with a 10% increment in FP, FN, and FL, or a 1-minute increase in TD.
RESULTS: FL had little impact on ΔMD (<0.2 decibels [dB] per 10% abnormal catch trials), and no level of FL produced ≥1 dB of ΔMD at any disease stage. FP yielded greater than expected MD, with a 10% increment in abnormal catch trials associated with a ΔMD = 0.42, 0.73, and 0.66 dB in mild (MD >-6 dB), moderate (-6 ≤MD <-12 dB), and severe (-12 ≤MD ≤-20 dB) disease, respectively, up to 20% abnormal catch trials, and a ΔMD = 1.57, 2.06, and 3.53 dB beyond 20% abnormal catch trials. FNs generally produced observed MDs below expected MDs. FN were minimally impactful up to 20% abnormal catch trials (ΔMD per 10% increment >-0.14 dB at all levels of severity). Beyond 20% abnormal catch trials, each 10% increment in abnormal catch trials was associated with a ΔMD = -1.27, -0.53, and -0.51 dB in mild, moderate, and severe disease, respectively. |ΔMD| ≥1 dB occurred with 22% FP and 26% FN in early, 14% FP and 34% FN in moderate, and 16% FP and 51% FN in severe disease. A 1-minute increment in TD produced ΔMDs between -0.35 and -0.40 dB.
CONCLUSIONS: FL have little impact on reliability in patients with established glaucoma. FP, and to a lesser extent FNs and TD, significantly affect reliability. The impact of FP and FN varies with disease severity and over the range of abnormal catch trials. On the basis of our findings, we present evidence-based, severity-specific standards for classifying VF reliability for clinical or research applications.
Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28676280      PMCID: PMC5675138          DOI: 10.1016/j.ophtha.2017.04.035

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  22 in total

1.  The relationship between better-eye and integrated visual field mean deviation and visual disability.

Authors:  Karun S Arora; Michael V Boland; David S Friedman; Joan L Jefferys; Sheila K West; Pradeep Y Ramulu
Journal:  Ophthalmology       Date:  2013-08-30       Impact factor: 12.079

2.  The influence of patient reliability on visual field outcome.

Authors:  M Lee; M Zulauf; J Caprioli
Journal:  Am J Ophthalmol       Date:  1994-06-15       Impact factor: 5.258

3.  Assessment of false positives with the Humphrey Field Analyzer II perimeter with the SITA Algorithm.

Authors:  Michelle R Newkirk; Stuart K Gardiner; Shaban Demirel; Chris A Johnson
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-10       Impact factor: 4.799

4.  Effect of intermittent versus continuous patient monitoring on reliability indices during automated perimetry.

Authors:  L N Johnson; A Aminlari; J W Sassani
Journal:  Ophthalmology       Date:  1993-01       Impact factor: 12.079

5.  A comparison of visual field progression criteria of 3 major glaucoma trials in early manifest glaucoma trial patients.

Authors:  Anders Heijl; Boel Bengtsson; Balwantray C Chauhan; Marc F Lieberman; Ian Cunliffe; Leslie Hyman; M Cristina Leske
Journal:  Ophthalmology       Date:  2008-04-18       Impact factor: 12.079

6.  Reduction of intraocular pressure and glaucoma progression: results from the Early Manifest Glaucoma Trial.

Authors:  Anders Heijl; M Cristina Leske; Bo Bengtsson; Leslie Hyman; Boel Bengtsson; Mohamed Hussein
Journal:  Arch Ophthalmol       Date:  2002-10

7.  Alteration of travel patterns with vision loss from glaucoma and macular degeneration.

Authors:  Frank C Curriero; Jessie Pinchoff; Suzanne W van Landingham; Luigi Ferrucci; David S Friedman; Pradeep Y Ramulu
Journal:  JAMA Ophthalmol       Date:  2013-11       Impact factor: 7.389

8.  A comparison of false-negative responses for full threshold and SITA standard perimetry in glaucoma patients and normal observers.

Authors:  Chris A Johnson; Kathryn Sherman; Carrie Doyle; Michael Wall
Journal:  J Glaucoma       Date:  2014 Jun-Jul       Impact factor: 2.503

9.  Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

Authors:  Francisco G Junoy Montolio; Christiaan Wesselink; Marijke Gordijn; Nomdo M Jansonius
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-10-09       Impact factor: 4.799

10.  Glaucomatous visual field loss associated with less travel from home.

Authors:  Pradeep Y Ramulu; Chad Hochberg; Eugenio A Maul; Emilie S Chan; Luigi Ferrucci; David S Friedman
Journal:  Optom Vis Sci       Date:  2014-02       Impact factor: 1.973

View more
  30 in total

1.  Comparing 10-2 and 24-2 Visual Fields for Detecting Progressive Central Visual Loss in Glaucoma Eyes with Early Central Abnormalities.

Authors:  Zhichao Wu; Felipe A Medeiros; Robert N Weinreb; Christopher A Girkin; Linda M Zangwill
Journal:  Ophthalmol Glaucoma       Date:  2019-01-14

2.  Greater Physical Activity Is Associated with Slower Visual Field Loss in Glaucoma.

Authors:  Moon Jeong Lee; Jiangxia Wang; David S Friedman; Michael V Boland; Carlos G De Moraes; Pradeep Y Ramulu
Journal:  Ophthalmology       Date:  2018-10-10       Impact factor: 12.079

3.  Evidence-Based Criteria for Determining Peripapillary OCT Reliability.

Authors:  Jithin Yohannan; Michael Cheng; Joseph Da; Sagar Chapagain; Ayodeji Sotimehin; Luke W Bonham; Aleksandra Mihailovic; Michael Boland; Pradeep Ramulu
Journal:  Ophthalmology       Date:  2019-08-29       Impact factor: 12.079

4.  Association Between 24-Hour Intraocular Pressure Monitored With Contact Lens Sensor and Visual Field Progression in Older Adults With Glaucoma.

Authors:  Carlos Gustavo De Moraes; Kaweh Mansouri; Jeffrey M Liebmann; Robert Ritch
Journal:  JAMA Ophthalmol       Date:  2018-07-01       Impact factor: 7.389

5.  Quantification of Visual Field Variability in Glaucoma: Implications for Visual Field Prediction and Modeling.

Authors:  Alessandro Rabiolo; Esteban Morales; Abdelmonem A Afifi; Fei Yu; Kouros Nouri-Mahdavi; Joseph Caprioli
Journal:  Transl Vis Sci Technol       Date:  2019-10-17       Impact factor: 3.283

6.  Patterns of Daily Physical Activity across the Spectrum of Visual Field Damage in Glaucoma Patients.

Authors:  Jian-Yu E; Jennifer A Schrack; Aleksandra Mihailovic; Amal A Wanigatunga; Sheila K West; David S Friedman; Laura N Gitlin; Tianjing Li; Pradeep Y Ramulu
Journal:  Ophthalmology       Date:  2020-06-29       Impact factor: 12.079

7.  The Effect of Transitioning from SITA Standard to SITA Faster on Visual Field Performance.

Authors:  Alex T Pham; Pradeep Y Ramulu; Michael V Boland; Jithin Yohannan
Journal:  Ophthalmology       Date:  2021-03-30       Impact factor: 14.277

8.  Impact of Visual Field Loss on Vision-Specific Quality of Life in African Americans: The African American Eye Disease Study.

Authors:  Dominic J Grisafe; Rohit Varma; Bruce S Burkemper; Benjamin Y Xu; Mina Torres; Alicia Fairbrother-Crisp; Cecilia M Patino; Roberta McKean-Cowdin
Journal:  Am J Ophthalmol       Date:  2021-02-08       Impact factor: 5.488

9.  Standard Reliability and Gaze Tracking Metrics in Glaucoma and Glaucoma Suspects.

Authors:  Andrew Steven Camp; Christopher P Long; Vincent Michael Patella; James A Proudfoot; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2021-07-17       Impact factor: 5.488

10.  The Association Between Intraocular Pressure and Visual Field Worsening in Treated Glaucoma Patients.

Authors:  Jithin Yohannan; Michael V Boland; Pradeep Ramulu
Journal:  J Glaucoma       Date:  2021-09-01       Impact factor: 2.290

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.