Anaphylactoid reactions in dialysis patients: role of ethylene-oxide.

J Bommer, O H Wilhelms, H P Barth, H Schindele, E Ritz.   

Abstract

To determine whether anaphylactoid reactions during dialysis are the result of allergy to ethylene oxide (EtO) used for sterilisation of dialysis equipment, EtO-specific cytophilic antibodies on basophils were detected by means of a sensitive protease-release assay. Antibodies were found in 2 of 44 healthy controls, 2 of 16 staff members, 4 of 17 patients with preterminal uraemia, and 35 of 83 dialysis patients. 22 of the dialysis patients with antibodies, but only 9 of those without had anaphylactoid reactions during dialysis. Symptoms were more common in patients with antibodies. Symptoms and antibodies were less in a unit where dialysers were rinsed more thoroughly, and were increased in patients with a history of atopy. EtO antibodies decreased or became undetectable in patients who were dialysed with non-EtO-sterilised equipment for eight weeks, and symptoms improved strikingly. On re-exposure to EtO-sterilised material, symptoms returned and EtO-induced protease release increased. EtO sterilisation of dialysis equipment should be discontinued.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 2867391     DOI: 10.1016/s0140-6736(85)92554-1

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  7 in total

Review 1.  Allergy to formaldehyde and ethylene-oxide.

Authors:  J Bousquet; F B Michel
Journal:  Clin Rev Allergy       Date:  1991 Fall-Winter

2.  Ethylene oxide and anaphylaxis during haemodialysis.

Authors:  A Nicholls
Journal:  Br Med J (Clin Res Ed)       Date:  1986-05-10

3.  [Complications of Redon drainage following hip joint replacement operations--an analysis of the causes].

Authors:  P Kirschner; H Römer; H P Werner
Journal:  Unfallchirurgie       Date:  1989-02

4.  Fall in peak expiratory flow during haemodialysis in patients with chronic renal failure.

Authors:  A Davenport; A J Williams
Journal:  Thorax       Date:  1988-09       Impact factor: 9.139

5.  [Problems of biocompatibility in hemodialysis treatment].

Authors:  J Bommer
Journal:  Klin Wochenschr       Date:  1986-09-15

6.  The effect of electronegativity and angiotensin-converting enzyme inhibition on the kinin-forming capacity of polyacrylonitrile dialysis membranes.

Authors:  Anik Désormeaux; Marie Eve Moreau; Yves Lepage; Jacques Chanard; Albert Adam
Journal:  Biomaterials       Date:  2008-03       Impact factor: 12.479

7.  Novel designed polyoxyethylene nonionic surfactant with improved safety and efficiency for anticancer drug delivery.

Authors:  Chang Li; Chunmeng Sun; Shasha Li; Peng Han; Huimin Sun; Ammar Ouahab; Yan Shen; Yourui Xu; Yerong Xiong; Jiasheng Tu
Journal:  Int J Nanomedicine       Date:  2014-04-28
  7 in total