Literature DB >> 2711525

[Complications of Redon drainage following hip joint replacement operations--an analysis of the causes].

P Kirschner1, H Römer, H P Werner.   

Abstract

After the introduction of Redon high-vacuum drainage, a considerable decrease in post-operative haematomas has been noted. But some of the complications could not be prevented by using the Redon system. They were in fact the result of it. The Redon system cannot be classified as a "closed" wound drainage. During bottle replacement, the system must be disconnected. An effective closed system must remain absolutely tight from application to removal of the drain so no possibility exists of contamination/infection from the outside. After introduction of a continuously absolutely closed system in a prospective study with three different systems the influence after hip joint arthroplasty operations on wound healing was investigated. The wounds were drained with the Redon high-vacuum system or the newly developed, permanently closed drainage system with maximum obtainable low pressure of 80% vacuum and 50% vacuum. Here the maximum obtainable vacuum builds up slowly in relation to the accumulated amount of wound fluids. The loss of low pressure in Redon systems differs between the drains. In the intra-articular drains the mixture of air and blood results in a linear decrease and follows not a hyperbola like in subcutaneous drains. Because of the high suction at the beginning of the Redon drainage necrotic muscle cells adhere to the outside of the drain openings and clogs them up mechanically. The stronger the suction effect on the tissue, the more fatty live cells and small vessels enter the lumen of the drain in the Redon system and 80% vacuum. This mechanisms result in bleeding from the drain canal after removal of the drain and "secondary" haematomas.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2711525

Source DB:  PubMed          Journal:  Unfallchirurgie        ISSN: 0340-2649


  19 in total

Review 1.  Abdominal drainage: a clinical review.

Authors:  T W O'Connor; T B Hugh
Journal:  Aust N Z J Surg       Date:  1979-04

2.  [Closure under reduced atmospheric pressure of extensive wounds].

Authors:  H REDON
Journal:  Mem Acad Chir (Paris)       Date:  1954 Mar 24-Apr 7

3.  [Physical flow studies of new surgical aspiration drains].

Authors:  L Kinzl; A Müller; D Wolter; C Burri
Journal:  Chirurg       Date:  1976-01       Impact factor: 0.955

4.  Postoperative infection in total prosthetic replacement arthroplasty of the hip-joint. With special reference to the bacterial content of the air of the operating room.

Authors:  J Charnley; N Eftekhar
Journal:  Br J Surg       Date:  1969-09       Impact factor: 6.939

5.  [Disturbances in surgical wound drains--principles and means of correction (author's transl)].

Authors:  K Tittel
Journal:  Unfallchirurgie       Date:  1981-12

6.  [Surgical suction drains. A comment on the paper by H. Lohfert (author's transl)].

Authors:  C Burri
Journal:  Unfallheilkunde       Date:  1980-07

7.  [Spiral drainage. An improved suction drainage].

Authors:  K Tittel; F Hufnagel; F Schauwecker
Journal:  Chirurg       Date:  1980-03       Impact factor: 0.955

8.  [Infections following orthopedic surgical intervention].

Authors:  R Plaue; P Hinz
Journal:  Arch Orthop Unfallchir       Date:  1971

9.  Infection after total hip replacement. With special reference to a discharge from the wound.

Authors:  V V Surin; K Sundholm; L Bäckman
Journal:  J Bone Joint Surg Br       Date:  1983-08

Review 10.  Wound infection: a review of diagnosis and treatment.

Authors:  R L Simmons
Journal:  Infect Control       Date:  1982 Jan-Feb
View more
  4 in total

1.  [The value of wound drainage with or without suction].

Authors:  J Schmidt; A Hasselbach; W Schnorr; T Baranek; R Letsch
Journal:  Unfallchirurg       Date:  2005-11       Impact factor: 1.000

2.  [Prevention of pocket-related complications following heart rhythm device implantation. D-Stat Hemostat™ versus vacuum drainage].

Authors:  Marc-Alexander Ohlow; Björn Buchter; Michele Brunelli; Bernward Lauer; Matthias Schreiber; J Christoph Geller
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-02-03

3.  [Gravity or suction drainage in thyroid surgery? Control of efficacy with ultrasound determination of residual hematoma].

Authors:  W Schwarz; C Willy; C Ndjee
Journal:  Langenbecks Arch Chir       Date:  1996

4.  Aprotinin and classic wound drainage are unnecessary in total hip replacement - a prospective randomized trial.

Authors:  F Fleischmann; C Matuschek; K Orth; P A Gerber; R Mota; W T Knoefel; M Peiper; M Schick; M van Griensven; Edwin Bölke; W Fleischmann
Journal:  Eur J Med Res       Date:  2011-01-27       Impact factor: 2.175

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.