| Literature DB >> 28670458 |
Bong Hyun Kim1, Young-Jun Kwon1, Young-Su Ju1, Bong Kyu Kim1, Hyun Seok Lee1, Sang-Gil Lee2, Yun Kyung Chung1.
Abstract
BACKGROUND: Clinicians who perform radiation therapy (RT) are exposed to radiation, which may negatively affect their health. The present study reports a case of acute lymphoblastic leukemia in a healthcare provider who was exposed to radiation at work; we also present a literature review of this topic. CASEEntities:
Keywords: Acute lymphoblastic leukemia; Brachytherapy; Cesium; Radiation oncologist
Year: 2017 PMID: 28670458 PMCID: PMC5485618 DOI: 10.1186/s40557-017-0186-8
Source DB: PubMed Journal: Ann Occup Environ Med ISSN: 2052-4374
Fig. 1a Location of the radioactive source, b Treatment tools used in brachytherapy of patients with cervical cancer. Cervix Cancer and Radiation, Available at https://youtu.be/20s1Gq4t7nY. Accessed 22 Feb 2016.
Spatial dose measurement record in the Cs-137 treatment room [Unit: mSv]
| Date | Room no. | Measuring point | Room no. | Measuring point | Room no. | Measuring point | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Entrance | 1 m | 0.3 m | Entrance | 1 m | 0.3 m | Entrance | 1 m | 0.3 m | ||||
| Jan.10.2001 | 533 | 0.04 | 0.25 | 1.60 | 633 | 0.04 | 0.25 | 2.15 | 733 | 0.04 | 0.25 | 2.20 |
| Feb.09.2001 | 533 | 0.04 | 0.15 | 1.15 | 633 | 0.04 | 0.25 | 2.10 | 733 | 0.04 | 0.20 | 2.10 |
| Feb.16.2001 | 533 | 0.04 | 0.20 | 1.35 | 633 | 0.04 | 0.32 | 2.40 | 733 | 0.04 | 0.25 | 2.30 |
| Mar.09.2001 | 533 | 0.04 | 0.15 | 1.40 | 633 | 0.04 | 0.40 | 2.55 | 733 | 0.04 | 0.30 | 2.45 |
| Mar.23.2001 | 533 | 0.04 | 0.10 | 1.20 | 633 | 0.04 | 0.20 | 2.10 | 733 | 0.04 | 0.32 | 2.45 |
| Apr.13.2001 | 533 | 0.04 | 0.15 | 1.45 | 633 | 0.04 | 0.25 | 2.15 | 733 | 0.04 | 0.25 | 2.28 |
| Apr.27.2001 | 533 | 0.04 | 0.20 | 1.30 | 633 | 0.04 | 0.30 | 2.20 | 733 | 0.04 | 0.32 | 2.40 |
| May.10.2001 | 533 | 0.04 | 0.20 | 1.25 | 633 | 0.04 | 0.20 | 2.10 | 733 | 0.04 | 0.20 | 2.30 |
| May.24.2001 | 533 | 0.04 | 0.25 | 1.35 | 633 | 0.04 | 0.30 | 2.30 | 733 | 0.04 | 0.25 | 2.25 |
| Jun.07.2001 | 533 | 0.04 | 0.25 | 1.40 | 633 | 0.04 | 0.25 | 2.25 | 733 | 0.04 | 0.25 | 2.30 |
| Jun.26.2001 | 533 | 0.04 | 0.10 | 1.25 | 633 | 0.04 | 0.25 | 2.30 | 733 | 0.04 | 0.30 | 2.45 |
| Jul.12.2001 | 533 | 0.04 | 0.25 | 1.20 | 633 | 0.04 | 0.35 | 2.30 | 733 | 0.04 | 0.30 | 2.40 |
| Jul.26.2001 | 533 | 0.04 | 0010 | 1.30 | 633 | 0.04 | 0.35 | 2.45 | 733 | 0.04 | 0.32 | 2.40 |
| Aug.23.2001 | 533 | 0.04 | 0.20 | 1.25 | 633 | 0.04 | 0.20 | 2.10 | 733 | 0.04 | 0.25 | 2.30 |
| Sep.06.2001 | 533 | 0.04 | 0.25 | 1.30 | 633 | 0.04 | 0.25 | 2.45 | 733 | 0.04 | 0.30 | 2.45 |
| Sep.20.2001 | 533 | 0.04 | 0.20 | 1.25 | 633 | 0.04 | 0.32 | 2.30 | 733 | 0.04 | 0.25 | 2.30 |
| Oct.11.2001 | 533 | 0.04 | 0.25 | 1.30 | 633 | 0.04 | 0.25 | 2.30 | 733 | 0.04 | 0.30 | 2.40 |
| Oct.18.2001 | 533 | 0.04 | 0.15 | 1.45 | 633 | 0.04 | 0.30 | 2.10 | 733 | 0.04 | 0.25 | 2.30 |
| Nov.08.2001 | 533 | 0.04 | 0.20 | 1.30 | 633 | 0.04 | 0.32 | 2.55 | 733 | 0.04 | 0.30 | 2.30 |
| Nov.29.2001 | 533 | 0.04 | 0.22 | 1.50 | 633 | 0.04 | 0.32 | 2.20 | 733 | 0.04 | 0.35 | 2.45 |
| Dec.06.2001 | 533 | 0.04 | 0.15 | 1.20 | 633 | 0.04 | 0.35 | 2.60 | 733 | 0.04 | 0.32 | 2.30 |
Radiation doses measured at 3 point: the entrance, 0.3 m and 1 m above bed, respectively, in hospital room number 533, 633, and 733. The case performed treatment in room number 633 and 733
Fig. 2Radiation exposure assessment during radioiodine treatment of the thyroid: Radiation exposure assessment data provided by the National Hospital