| Literature DB >> 28670027 |
Tiago Rocha Dias1, João de Deus da Costa Alves Junior2, Nitamar Abdala3.
Abstract
OBJECTIVE: To develop a simulator for training in fluoroscopy-guided facet joint injections and to evaluate the learning curve for this procedure among radiology residents.Entities:
Keywords: Injections, intra-articular; Injections, spinal; Learning curve; Models, anatomic; Radiology, interventional; Zygapophyseal joint
Year: 2017 PMID: 28670027 PMCID: PMC5487230 DOI: 10.1590/0100-3984.2015.0176
Source DB: PubMed Journal: Radiol Bras ISSN: 0100-3984
Figure 1Spine model composed of five lumbar vertebrae placed within a silicon mold.
Figure 2Assembling the model.
Figure 3Radiographic appearance of an appropriate procedure.
Figure 4Graphical representation of the procedure time (in seconds) for the injections carried out.
Estimates obtained in the potential model for procedure time.
| Fluoroscopy time estimated for the first injection | Slope of the curve | Quality of the adjustment | ||||||
|---|---|---|---|---|---|---|---|---|
| Volunteer | α | Standard error | β | Standard error | R2 | Learning rate | ||
| 1 | 2.999 | 0.802 | -0.293 | 0.124 | 0.283 | 81.6% | ||
| 2 | 1.862 | 0.441 | -0.335 | 0.114 | 0.397 | 79.3% | ||
| 3 | 1.640 | 0.299 | -0.308[ | 0.088 | 0.465 | 80.8% | ||
| 4 | 1.315 | 0.415 | -0.319 | 0.153 | 0.250 | 80.2% | ||
| 5 | 1.086 | 0.187 | -0.262[ | 0.083 | 0.413 | 83.4% | ||
| 6 | 0.818 | 0.192 | -0.253 | 0.113 | 0.262 | 83.9% | ||
| 7 | 1.215 | 0.185 | -0.374‡ | 0.074 | 0.648 | 77.2% | ||
| 8 | 1.088 | 0.153 | -0.354‡ | 0.068 | 0.657 | 78.2% | ||
| 9 | 0.898 | 0.102 | -0.359‡ | 0.055 | 0.754 | 78.0% | ||
| 10 | 1.165 | 0.113 | -0.355‡ | 0.047 | 0.803 | 78.2% | ||
| 11 | 1.494 | 0.254 | -0.545‡ | 0.082 | 0.757 | 68.5% | ||
| 12 | 0.942 | 0.087 | -0.362‡ | 0.045 | 0.824 | 77.8% | ||
| Mean | 1.38 | -0.34 | 0.54 | 78.9% | ||||
| Standard deviation | 0.60 | 0.07 | 0.22 | 3.9% | ||||
| Coefficient of variation | 43.38% | 21.81% | 40.73% | 5.0% | ||||
p ≤ 0.001 and
p ≤ 0.003 for the hypothesis β = 0.
Figure 5Graphical representation of the fluoroscopy time (in minutes) of the injections carried out. Equations represent the adjustment of the Wright model. y, fluoroscopy time; x, cumulative number of injections; R = coefficient of determination (quality of the adjustment).
Estimates obtained in the potential model for fluoroscopy time.
| Fluoroscopy time estimated for the first injection | Slope of the curve | Quality of the adjustment | ||||||
|---|---|---|---|---|---|---|---|---|
| Volunteer | α | Standard error | β | Standard error | R2 | Learning rate | ||
| 1 | 2.999 | 0.802 | -0.293 | 0.124 | 0.283 | 81.6% | ||
| 2 | 1.862 | 0.441 | -0.335 | 0.114 | 0.397 | 79.3% | ||
| 3 | 1.640 | 0.299 | -0.308[ | 0.088 | 0.465 | 80.8% | ||
| 4 | 1.315 | 0.415 | -0.319 | 0.153 | 0.250 | 80.2% | ||
| 5 | 1.086 | 0.187 | -0.262[ | 0.083 | 0.413 | 83.4% | ||
| 6 | 0.818 | 0.192 | -0.253 | 0.113 | 0.262 | 83.9% | ||
| 7 | 1.215 | 0.185 | -0.374[ | 0.074 | 0.648 | 77.2% | ||
| 8 | 1.088 | 0.153 | -0.354[ | 0.068 | 0.657 | 78.2% | ||
| 9 | 0.898 | 0.102 | -0.359[ | 0.055 | 0.754 | 78.0% | ||
| 10 | 1.165 | 0.113 | -0.355[ | 0.047 | 0.803 | 78.2% | ||
| 11 | 1.494 | 0.254 | -0.545[ | 0.082 | 0.757 | 68.5% | ||
| 12 | 0.942 | 0.087 | -0.362[ | 0.045 | 0.824 | 77.8% | ||
| Mean | 1.38 | -0.34 | 0.54 | 78.9% | ||||
| Standard deviation | 0.60 | 0.07 | 0.22 | 3.9% | ||||
| Coefficient of variation | 43.38% | 21.81% | 40.73% | 5.0% | ||||
p ≤ 0.05,
p ≤ 0.01 and
p ≤ 0.001 for the hypothesis β = 0.
Figure 6Graphical representation of the absolute frequencies of appropriate and inappropriate procedures during the two phases of the training.