Image quality evaluation of dual-layer spectral detector CT of the chest and comparison with conventional CT imaging.

Jonas Doerner1, Myriam Hauger2, Tilman Hickethier2, Jonathan Byrtus2, Christian Wybranski2, Nils Große Hokamp2, David Maintz2, Stefan Haneder2.   

Abstract

OBJECTIVES: To evaluate image quality parameters of virtual mono-energetic (MonoE) and conventional (CR) imaging derived from a dual-layer spectral detector CT (DLCT) in oncological follow-up venous phase imaging of the chest and comparison with conventional multi-detector CT (CRMDCT) imaging.
MATERIALS AND METHODS: A total of 55 patients who had oncologic staging with conventional CT and DLCT of the chest in venous phase were included in this study. Established image quality parameters were derived from all datasets in defined thoracic landmarks. Attenuation, image noise, and signal-/contrast- to noise ratios (SNR, CNR) were compared between CRDLCT and MonoE as well as CRMDCT imaging. Two readers performed subjective image analysis.
RESULTS: CRMDCT showed significant lower attenuation values compared to CRDLCT and MonoE at 40-70keV (p≤0.05). Moreover, MonoE at 40-70keV revealed significantly higher attenuations values compared to CRDLCT (p<0.001). Noise was statistically lower in CRMDCT compared with CRDLCT and MonoE at 40keV (11.4±2.3 HU vs. 12.0±3.1 HU vs. 11.7±5.2 HU; p<0.001). In contrast, all MonoE levels showed significantly lower noise levels compared to CRDLCT (p<0.001). SNR was not significantly different between CRMDCT and CRDLCT (13.5±3.7 vs. 14.4±5.3; p>0.99). SNR values were significantly increased for MonoE at 40-80keV compared to CRMDCT and CRDLCT (p<0.001). CRDLCT and MonoE (40-70keV) from DLCT revealed significantly higher CNR values than CRMDCT (p<0.001). In subjective analysis, MonoE at 40keV surpassed all other image reconstructions except for noise in MonoE at 70 keV.
CONCLUSION: In dual-layer spectral detector CT, MonoE at low keV showed superior image quality compared to conventional images derived from the same system and may therefore be added to clinical routine imaging protocols. Whether MonoE reconstructions yield additional diagnostic information is still unknown.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chest; Dual-layer detector CT; Spectral detector CT; Virtual mono-energetic imaging

Mesh:

Substances:

Year:  2017        PMID: 28668431     DOI: 10.1016/j.ejrad.2017.05.016

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  13 in total

1.  Dual-energy CT: a phantom comparison of different platforms for abdominal imaging.

Authors:  Thorsten Sellerer; Peter B Noël; Manuel Patino; Anushri Parakh; Sebastian Ehn; Sascha Zeiter; Jasmin A Holz; Johannes Hammel; Alexander A Fingerle; Franz Pfeiffer; David Maintz; Ernst J Rummeny; Daniela Muenzel; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2018-02-05       Impact factor: 5.315

2.  Dual-layer DECT for multiphasic hepatic CT with 50 percent iodine load: a matched-pair comparison with a 120 kVp protocol.

Authors:  Yasunori Nagayama; Takeshi Nakaura; Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Yuji Iyama; Narumi Taguchi; Tomohiro Namimoto; Hideaki Yuki; Masafumi Kidoh; Kenichiro Hirata; Masataka Nakagawa; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2017-10-23       Impact factor: 5.315

3.  Myocardial Late Iodine Enhancement and Extracellular Volume Quantification with Dual-Layer Spectral Detector Dual-Energy Cardiac CT.

Authors:  Seitaro Oda; Takafumi Emoto; Takeshi Nakaura; Masafumi Kidoh; Daisuke Utsunomiya; Yoshinori Funama; Yasunori Nagayama; Seiji Takashio; Mitsuharu Ueda; Taro Yamashita; Kenichi Tsujita; Yukio Ando; Yasuyuki Yamashita
Journal:  Radiol Cardiothorac Imaging       Date:  2019-04-25

4.  The application of dual-layer spectral detector computed tomography in solitary pulmonary nodule identification.

Authors:  Qingyun Wen; Yong Yue; Jin Shang; Xiaomei Lu; Lu Gao; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2021-02

5.  Dual-layer spectral computed tomography: measuring relative electron density.

Authors:  Kai Mei; Sebastian Ehn; Markus Oechsner; Felix K Kopp; Daniela Pfeiffer; Alexander A Fingerle; Franz Pfeiffer; Stephanie E Combs; Jan J Wilkens; Ernst J Rummeny; Peter B Noël
Journal:  Eur Radiol Exp       Date:  2018-08-22

6.  Computed tomography pulmonary angiograms using a novel dual-layer spectral detector: Adjusted window settings are essential for diagnostic image quality.

Authors:  Andra-Iza Iuga; Jonas Doerner; Florian Siedek; Stefan Haneder; Jonathan Byrtus; Julian A Luetkens; David Maintz; Tilman Hickethier
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

7.  Evaluation of soft-plaque stenoses in coronary artery stents using conventional and monoenergetic images: first in-vitro experience and comparison of two different dual-energy techniques.

Authors:  Tilman Hickethier; Justus Wenning; Grischa Bratke; David Maintz; Guido Michels; Alexander C Bunck
Journal:  Quant Imaging Med Surg       Date:  2020-03

8.  The optimal monoenergetic spectral image level of coronary computed tomography (CT) angiography on a dual-layer spectral detector CT with half-dose contrast media.

Authors:  Xin Huang; Sizhe Gao; Yue Ma; Xiaomei Lu; Zheng Jia; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2020-03

9.  Added value of spectral parameters for the assessment of lymph node metastasis of lung cancer with dual-layer spectral detector computed tomography.

Authors:  Lu Gao; Xiaomei Lu; Qingyun Wen; Yang Hou
Journal:  Quant Imaging Med Surg       Date:  2021-06

10.  Utilization of virtual low-keV monoenergetic images generated using dual-layer spectral detector computed tomography for the assessment of peritoneal seeding from ovarian cancer.

Authors:  Taek Min Kim; Sang Youn Kim; Jeong Yeon Cho; Seung Hyup Kim; Min Hoan Moon
Journal:  Medicine (Baltimore)       Date:  2020-06-05       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.