Literature DB >> 28667186

Analytically Sensitive Protein Detection in Microtiter Plates by Proximity Ligation with Rolling Circle Amplification.

Tonge Ebai1, Felipe Marques Souza de Oliveira1, Liza Löf1, Lotta Wik1, Caroline Schweiger2,3, Anders Larsson4, Ulrich Keilholtz3, Johannes Haybaeck2,5, Ulf Landegren6, Masood Kamali-Moghaddam6.   

Abstract

BACKGROUND: Detecting proteins at low concentrations in plasma is crucial for early diagnosis. Current techniques in clinical routine, such as sandwich ELISA, provide sensitive protein detection because of a dependence on target recognition by pairs of antibodies, but detection of still lower protein concentrations is often called for. Proximity ligation assay with rolling circle amplification (PLARCA) is a modified proximity ligation assay (PLA) for analytically specific and sensitive protein detection via binding of target proteins by 3 antibodies, and signal amplification via rolling circle amplification (RCA) in microtiter wells, easily adapted to instrumentation in use in hospitals.
METHODS: Proteins captured by immobilized antibodies were detected using a pair of oligonucleotide-conjugated antibodies. Upon target recognition these PLA probes guided oligonucleotide ligation, followed by amplification via RCA of circular DNA strands that formed in the reaction. The RCA products were detected by horseradish peroxidase-labeled oligonucleotides to generate colorimetric reaction products with readout in an absorbance microplate reader.
RESULTS: We compared detection of interleukin (IL)-4, IL-6, IL-8, p53, and growth differentiation factor 15 (GDF-15) by PLARCA and conventional sandwich ELISA or immuno-RCA. PLARCA detected lower concentrations of proteins and exhibited a broader dynamic range compared to ELISA and iRCA using the same antibodies. IL-4 and IL-6 were detected in clinical samples at femtomolar concentrations, considerably lower than for ELISA.
CONCLUSIONS: PLARCA offers detection of lower protein levels and increased dynamic ranges compared to ELISA. The PLARCA procedure may be adapted to routine instrumentation available in hospitals and research laboratories.
© 2017 American Association for Clinical Chemistry.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28667186     DOI: 10.1373/clinchem.2017.271833

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  8 in total

Review 1.  Antibody validation: a view from the mountains.

Authors:  Michael J Taussig; Cláudia Fonseca; James S Trimmer
Journal:  N Biotechnol       Date:  2018-08-04       Impact factor: 5.079

2.  Coupling antibody based recognition with DNA based signal amplification using an electrochemical probe modified with MnO2 nanosheets and gold nanoclusters: Application to the sensitive voltammetric determination of the cancer biomarker alpha fetoprotein.

Authors:  Wen Xiang; Guanwu Wang; Shuang Cao; Qiuguo Wang; Xiangyue Xiao; Ting Li; Minghui Yang
Journal:  Mikrochim Acta       Date:  2018-06-23       Impact factor: 5.833

3.  Improved efficiency of in situ protein analysis by proximity ligation using UnFold probes.

Authors:  Axel Klaesson; Karin Grannas; Tonge Ebai; Johan Heldin; Björn Koos; Mattias Leino; Doroteya Raykova; Johan Oelrich; Linda Arngården; Ola Söderberg; Ulf Landegren
Journal:  Sci Rep       Date:  2018-03-29       Impact factor: 4.379

Review 4.  Current and Future Perspectives on Isothermal Nucleic Acid Amplification Technologies for Diagnosing Infections.

Authors:  Godwin Attah Obande; Kirnpal Kaur Banga Singh
Journal:  Infect Drug Resist       Date:  2020-02-12       Impact factor: 4.003

Review 5.  Applications of DNA-Functionalized Proteins.

Authors:  Zhaoqiu Gong; Yuanyuan Tang; Ningning Ma; Wenhong Cao; Yong Wang; Shuang Wang; Ye Tian
Journal:  Int J Mol Sci       Date:  2021-11-29       Impact factor: 5.923

6.  Sequential Protein Capture in Multiplex Single Molecule Arrays: A Strategy for Eliminating Assay Cross-Reactivity.

Authors:  Tal Gilboa; Adam M Maley; Alana F Ogata; Connie Wu; David R Walt
Journal:  Adv Healthc Mater       Date:  2020-09-06       Impact factor: 9.933

Review 7.  Smartphone-based clinical diagnostics: towards democratization of evidence-based health care.

Authors:  I Hernández-Neuta; F Neumann; J Brightmeyer; T Ba Tis; N Madaboosi; Q Wei; A Ozcan; M Nilsson
Journal:  J Intern Med       Date:  2018-09-12       Impact factor: 8.989

Review 8.  Cancer diagnostics based on plasma protein biomarkers: hard times but great expectations.

Authors:  Ulf Landegren; Maria Hammond
Journal:  Mol Oncol       Date:  2020-11-17       Impact factor: 6.603

  8 in total