Literature DB >> 28665477

Visual acuity and image quality in 5 diffractive intraocular lenses.

Genís Cardona1, Fidel Vega1, Miguel A Gil2, Consuelo Varón1, José A Buil2, María S Millán1.   

Abstract

PURPOSE: To compare objective image quality at distant, intermediate, and near foci with the corresponding visual acuity (VA) in patients symmetrically implanted with 5 different diffractive multifocal intraocular lenses (IOLs) (ReSTOR SV25T0, Tecnis ZKB00, Tecnis ZLB00, AT LISA 809, and AT LISA Tri 839MP) and a monofocal lens (Tecnis ZA9003) 3 months after cataract intervention.
METHODS: Objective image quality, measured as the area under the modulation transfer function curve (AMTF), was tested in vitro in an eye model. In addition, corrected distance visual acuity and distance-corrected intermediate and near visual acuities (DCIVA and DCNVA) were assessed in a group of 79 patients, randomly implanted with one of the lenses.
RESULTS: Image quality and VA at the distant focus was good for all lens designs, but was similarly compromised at the intermediate focus, where the best DCIVA corresponded to the low add ZKB00. At the near focus, the monofocal lens and the distance dominant SV25T0 had the worst AMTF values, with the ZLB00 presenting the best DCNVA. The relationship between AMTF and VA was found not to be linear, with VA being similarly good for AMTF values over a certain threshold.
CONCLUSIONS: Visual acuity of pseudophakic patients reflected the optical quality of the specific IOL design within a certain range of measurements, beyond which maximum VA is limited by other ocular, optical, and neuropsychophysical factors.

Entities:  

Keywords:  Diffractive optics; Intraocular lens; Multifocal; Objective image quality; Visual acuity

Mesh:

Year:  2018        PMID: 28665477     DOI: 10.5301/ejo.5000994

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  6 in total

1.  Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design.

Authors:  Fidel Vega; Maria S Millán; Nuria Garzón; Irene Altemir; Francisco Poyales; Jose Manuel Larrosa
Journal:  Biomed Opt Express       Date:  2018-09-17       Impact factor: 3.732

Review 2.  Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.

Authors:  Sophie Maedel; Jennifer R Evans; Annette Harrer-Seely; Oliver Findl
Journal:  Cochrane Database Syst Rev       Date:  2021-08-16

3.  Evaluation of Visual and Subjective Outcomes with Mix-and-Match of Three One-Piece Tecnis Multifocal IOLs of Varying Add Powers.

Authors:  Steven J Dell
Journal:  Clin Ophthalmol       Date:  2020-09-29

4.  Extended depth of focus intraocular lens: Chromatic performance.

Authors:  Maria S Millán; Fidel Vega
Journal:  Biomed Opt Express       Date:  2017-08-31       Impact factor: 3.732

5.  A clinical assessment of visual performance of combining the TECNIS® Symfony Extended Range of Vision IOL (ZXR00) with the +3.25 D TECNIS Multifocal 1-piece IOL (ZLB00) in subjects undergoing bilateral cataract extraction.

Authors:  Sondra Black
Journal:  Clin Ophthalmol       Date:  2018-10-23

6.  Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses.

Authors:  Jae Hyuck Lee; Ho Seok Chung; Su Young Moon; So Young Park; Hun Lee; Jae Yong Kim; Hungwon Tchah
Journal:  J Ophthalmol       Date:  2021-08-03       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.