PURPOSE: To determine iridocorneal angle changes produced after 2 years of implantable collamer lens (ICL) V4c (STAAR Surgical AG, Nidau, Switzerland) placement by Fourier-domain optical coherence tomography (FD-OCT).
DESIGN: Prospective interventional case series.
METHODS: In 54 eyes of 27 myopic subjects FD-OCT iridocorneal angle measurements were made before and 1 month, 3 months, 1 year, and 2 years after ICL implant. Trabecular-iris angle (TIA), angle opening distance 500 μm from the scleral spur (AOD500), and iridotrabecular contact length (TICL) were compared among these time points and the nasal, temporal, and inferior quadrants.
RESULTS: Preoperative TIAs were 49.5 ± 8.7, 48.3 ± 9.6, and 49.1 ±8.6 degrees for the nasal, temporal and inferior quadrants (P < .001). Corresponding values were 29.9 ± 10.4, 28.4 ± 10.8, and 28.8 ± 9.7 degrees at 1 month and 27.3 ± 8.8, 26.8 ± 8.1, and 28.9 ± 7 degrees at 2 years of follow-up, indicating angle narrowing of 39%-45% and no further narrowing beyond 1 month in the nasal (P = .133), temporal (P = .376), and inferior (P = 1.000) quadrants. Trabecular-iris contact (TIC) was observed in 8 eyes of 8 subjects, mostly only in the temporal quadrant. Mean TICL failed to vary during follow-up (307 ± 288 μm at 3 months and 225 ± 142 μm at 2 years, P = .159).
CONCLUSIONS: In response to ICL V4c implant, considerable angle narrowing was detected at 1 month but this narrowing remained stable at 2 years. In the 8 cases of TIC, no progression of contact was observed beyond 3 months postimplant.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28662940     DOI: 10.1016/j.ajo.2017.06.018

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  6 in total

Review 1.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

2.  The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation.

Authors:  Zongli Hu; Chunlin Chen; Min Sun; Rongdi Yuan; Jian Ye
Journal:  J Ophthalmol       Date:  2020-07-21       Impact factor: 1.909

3.  Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens.

Authors:  José Ignacio Fernández-Vigo; Alfonso C Marcos; Rafael Agujetas; José María Montanero; Inés Sánchez-Guillén; Julián García-Feijóo; Adrián Pandal-Blanco; José Ángel Fernández-Vigo; Ana Macarro-Merino
Journal:  PLoS One       Date:  2018-08-13       Impact factor: 3.240

4.  Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses.

Authors:  Jiao Zhao; Jing Zhao; Wen Yang; Huamao Miao; Lingling Niu; Jianmin Shang; Xiaoying Wang; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2021-01-27

5.  Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens.

Authors:  Yuki Takagi; Takashi Kojima; Tomoya Nishida; Tomoaki Nakamura; Kazuo Ichikawa
Journal:  PLoS One       Date:  2020-11-16       Impact factor: 3.240

6.  Assessment of low-vault cases with an implantable collamer lens.

Authors:  Sayaka Kato; Kimiya Shimizu; Akihito Igarashi
Journal:  PLoS One       Date:  2020-11-04       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.