Literature DB >> 28659995

Maxillary Overdenture Retained with an Implant Support CAD-CAM Bar: A 4 Years Follow Up Case.

Massimo Corsalini1, Daniela Di Venere1, Gianluca Stefanachi1, Giovannino Muci1, Andrea Palminteri1, Alessandra Laforgia1, Francesco Pettini1.   

Abstract

INTRODUCTION: Oral rehabilitation with overdenture on implants of upper jaw must be taken into consideration a variety of anatomical and biomechanical issues. It is possible to provide for rehabilitation with two or more implants, in different positions, solidarizing them with a bar. MATERIALS &
METHODS: The present study involved a patient rehabilitated with 4 Xive implants (Friadent GmbH, Mannheim, Germany) solidarized with a titanium bar crafted with CAD-CAM technology for maximal comfort, precision and structural lightness. RESULTS & DISCUSSION: The follow-up was 54 months, with an implant survival of 100%. Based on our clinical evidence, bars engineered with CAD-CAM technology are promising in terms of precision and comfort despite higher costs.

Entities:  

Keywords:  CAD-CAM bar; Implant rehabilitation; Overdenture; Prosthetic rehabilitation; Upper jaw

Year:  2017        PMID: 28659995      PMCID: PMC5470066          DOI: 10.2174/1874210601711010247

Source DB:  PubMed          Journal:  Open Dent J        ISSN: 1874-2106


INTRODUCTION

According to the definition of Glossary of Prosthodontic Terms [1], “overdenture” is a removable, partial or total, prosthesis supported by one or more residual teeth, roots or implants [2]. The oral rehabilitation of edentulous jaw by combining 4 implants, 2 straight medially and 2 tilted distally, was developed to overcome the anatomic limitations related to bone loss, and where it is difficult to treat the patients without complex augmentative techniques [3, 4] Cast metal bars have been used in implant supported overdentures as a solution to increase the strength of an acrylic prosthesis and equally distribute load barring forces across the implants. However, the traditional bar for either an overdenture or fixed denture uses cast high noble metal alloys, and because of the increasing cost of gold, complex and time consuming laboratory procedures, commercial laboratories are starting to use the CAD-CAM technology to create the prosthetic framework. Advances in CAD-CAM technology have brought about production techniques, that are faster and more precise, increasing the efficiency in which implant bars are fabricated, and greatly improving predictability upon seating. Although implant supported overdentures are widely considered an appropriate therapy for edentulous patients, late implant failures have been reported [5], and the most frequent cause is the biomechanical overload of the implants that deteriorates the attachment system [6]. The bar design in itself is biomechanically advantageous [7, 8], and it could increase the success rate of an implant supported prosthesis, especially for maxillary edentulous patients: An implant supported maxillary denture on at least 4 implants and provided with a bar anchorage is a proper treatment option for the edentulous maxilla. Disadvantages of the bar system were also reported, and these were mainly hygiene-related complications due to the difficulty in cleaning the peri-implant zone [9]. The aim of the present study is the critical re-assessment of implant-prosthetic treatment plans in patients with total maxillary edentulia. The clinical success criteria of the present study comprise [3, 10] optimal aesthetic integration of the prosthetic rehabilitation in the smile exposure and the impact of the frontal group in the facial context; prosthetic retentivity and stability; reinstatement of the masticatory function; easy access to home oral hygiene manoeuvres.

MATERIALS AND METHODS

A patient 73 years old, female, with maxillary edentulism since three years with significant bone resorption was selected (Fig. ), the patient described in the case report has given informed consent for the case report to be published. The patient did not smoke, wasn’t under radiation therapy of head or neck, intravenous bisphosphonate therapy, allergic to restorative materials used. In the present study Xive® S (Friadent GmbH, Mannheim, Germany) implants were placed with minimal length of 9, 5 mm and maximal length of 11 mm, diameters of 3.8 mm, with cylindrical geometry.

Surgical Phase

Four implants, in just one surgical time and with guided surgery, using a surgical template obtained from a scan with denture in place in patient’s mouth [3], were positioned in the patient: the two distal implants were located in 1.5-2.5 spots, the two central implants in 1.2-2.2 spots (Fig. ) [11]. Regarding the importance of symmetry of anchorages, the ideal situation is represented by the presence of two pillars in the canine zones and other two in the pre-molar zones since it enables the realization of a support polygon also avoiding the overdenture rotation axis [3, 10]. Furthermore, great care was given to the control of the axis parallelism. The insertion torque was at least 35 Ncm.

Prosthetic Phase

After the osteointegration, healing and maturation of tissues completed after six months (Fig. ), we proceeded to the collection of dental print using a polyeter Fig. () (Impregum DuoSoft H, 3M ESPE, MN, USA). Once the model was crafted, the technician realized a bar in chalk (Fig. ): It was screwed together with the stumps directly in the mouth; the absence of fractures is considered a positive result. The precision of the master model was then assessed, it being of fundamental importance as to obtain the passivity of the future structure. Starting from the master model, the technician made a wax base plate (Fig. ): An intraoral test was performed so as to verify the vertical dimension, the parallelism in respect to the Camper plan and the bi-pupillary line. The technician then performed the teeth mounting test. Once the master model and the wax base were made by means of the teeth mounting test, the data of the models were collected with a dedicated scanner by COMPARTIS ISUS® (Manufacturing Center, E.S. Healthcare N.V. Research Campus 10, 3500 Hasselt, Belgium) and a virtual object was then elaborated in 3D (CAD) [12]. After processing, the files were forwarded through electronic transmission to the production plant for the CAM milling of the object according to industrial quality standards (Figs. -). The CAD-CAM system used was COMPARTIS ISUS® (Manufacturing Center, E.S. Healthcare N.V. Research Campus 10, 3500 Hasselt, Belgium). The intraoral test of the main connector was then performed in order to test the fitting with the bar (Fig. ).

RESULTS AND DISCUSSION

Maxillary implant overdentures with at least 4 splinted implants experienced high implant and prosthetic survival rates [10, 13]; furthermore there was an increased risk of implant loss when 4 or minus implants and non splinted implants were used [14]. In the present study the implant survival was 100% after 54 months (Fig. ). It should be considered that this is a short follow up time but the implant supported rehabilitation has been realized in a patient with severe bone atrophy. Moreover, we achieved a high comfort for the patient thanks to the significant stability of the overdenture and the absence of the prosthetic palate (Figs. -). Patient satisfaction with function and esthetics was assessed by using a scale with ratings 1-10 with 10 = fully satisfied and 1 = not satisfied [3]. Points in favour of the choice of a removable implant support prosthesis are: Simplified, aesthetically profitable rehabilitation even of crests undergoing resorption (it allows to avoid GBR); favourable premises for correct phonetics; compared to mixed-support overdentures bar-sustained overdentures do not display laying nor dislocation and compression of mucosa, minimising the effects of bone resorption typical of removable rehabilitations [3, 10, 15-17]. The use of a bar-sustained overdenture compared to a fixed rehabilitation gives some advantages: a predictable management of the aesthetics; easier home hygiene [18-20]; the total implant support reduces the resorption of the bone crest; avoidance of the resin palate from the prosthetic design granting a higher comfort. In our patient we used a CAD-CAM titanium bar [12] that give us many advantages: tension-less fit; system usable with all implant interfaces; positioning of the structure on implant level (which can be screwed directly to the internal connections of implants) or on abutment; use of only one metal (pure titanium grade 2) [21]; less time consumption and laboratory work; micrometric precision: the producer guarantees discrepancies below 20 μm on the vertical axis, and below 30 μm on the horizontal axis.

CONCLUSION

The technical reasons for the choice of a CAD-CAM milled bar compared to a bar engineered with conventional techniques are: Solidity [22] (realization from a sole piece and absence of welding); precision [22] (absence of misfit and subsequent passivization at the tightening of the connection screws, and absence of stress on implants and bone-implant interface); lightness (low specific weight of titanium) and possibility to directly insert the milled bar into the internal connection implant.
Implants position Diameter (mm) Lenght (mm)
1.53.89,5
1.23.89,5
2.23.89,5
2.53.811
  22 in total

1.  Function and clinical application of dental CAD/CAM "GN-1".

Authors:  K Hikita; Y Uchiyama; K Iiyama; F Duret
Journal:  Int J Comput Dent       Date:  2002-01       Impact factor: 1.883

Review 2.  Treatment considerations for maxillary implant overdentures: a systematic review.

Authors:  Steven J Sadowsky
Journal:  J Prosthet Dent       Date:  2007-06       Impact factor: 3.426

3.  Four-implant overdenture fully supported by a CAD-CAM titanium bar: A single-cohort prospective 1-year preliminary study.

Authors:  Alessandro Pozzi; Marco Tallarico; Peter K Moy
Journal:  J Prosthet Dent       Date:  2016-05-07       Impact factor: 3.426

4.  Scanning electron microscopy observations of failures of implant overdenture bars: a case series report.

Authors:  J Neil Waddell; Alan G T Payne; Michael V Swain; Jules A Kieser
Journal:  Clin Implant Dent Relat Res       Date:  2010-03       Impact factor: 3.932

Review 5.  A systematic review of implant-supported overdentures in the edentulous maxilla, compared to the mandible: how many implants?

Authors:  Gerry M Raghoebar; Henny J A Meijer; Wim Slot; James J R Slater; Arjan Vissink
Journal:  Eur J Oral Implantol       Date:  2014       Impact factor: 3.123

6.  Plaque Accumulation Beneath Maxillary All-on-4™ Implant-Supported Prostheses.

Authors:  Samer Abi Nader; Hazem Eimar; Moath Momani; Ke Shang; Nach G Daniel; Faleh Tamimi
Journal:  Clin Implant Dent Relat Res       Date:  2014-01-27       Impact factor: 3.932

7.  Patient-reported outcomes of maxillary implant-supported overdentures compared with conventional dentures.

Authors:  Anja Zembic; Daniel Wismeijer
Journal:  Clin Oral Implants Res       Date:  2013-04-15       Impact factor: 5.977

8.  Milled bar-supported implant overdenture after mandibular resection: a case report.

Authors:  Renata Vecchiatini; Nicola Mobilio; Demis Barbin; Santo Catapano; Giorgio Calura
Journal:  J Oral Implantol       Date:  2009       Impact factor: 1.779

9.  A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems.

Authors:  Cuneyt Karabuda; Mehmet Yaltirik; Mehmet Bayraktar
Journal:  Implant Dent       Date:  2008-03       Impact factor: 2.454

10.  Mandibular overdentures supported by two or four endosseous implants: a 10-year clinical trial.

Authors:  Henny J A Meijer; Gerry M Raghoebar; Rutger H K Batenburg; Anita Visser; Arjan Vissink
Journal:  Clin Oral Implants Res       Date:  2009-03-27       Impact factor: 5.977

View more
  3 in total

1.  Peri-Implant Bone Loss at Implants Placed in Preserved Alveolar Bone Versus Implants Placed in Native Bone: A Retrospective Radiographic Study.

Authors:  Johann Bui Quoc; Aurélie Vang; Laurence Evrard
Journal:  Open Dent J       Date:  2018-07-31

2.  Obturator Prosthesis Rehabilitation after Maxillectomy: Functional and Aesthetical Analysis in 25 Patients.

Authors:  Massimo Corsalini; Giuseppe Barile; Santo Catapano; Annamaria Ciocia; Assunta Casorelli; Rosaria Siciliani; Daniela Di Venere; Saverio Capodiferro
Journal:  Int J Environ Res Public Health       Date:  2021-11-28       Impact factor: 3.390

3.  Fabrication of a customized impression metal jig for an implant-supported overdenture with a milled bar.

Authors:  Yeganeh Memari; Azadeh Tadayonfard; Amir Fayaz; Elaheh Beyabanaki
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.