Literature DB >> 24461161

Plaque Accumulation Beneath Maxillary All-on-4™ Implant-Supported Prostheses.

Samer Abi Nader1, Hazem Eimar1, Moath Momani2, Ke Shang3, Nach G Daniel4, Faleh Tamimi1.   

Abstract

BACKGROUND: Maxillary prostheses supported by four implants, following the All-on-4(™) principles, have become an accepted effective treatment for totally edentulous patients. Maintaining the hygiene of such fixed implant-supported prostheses is challenging.
PURPOSE: The purpose of this clinical study was to evaluate the distribution of plaque on the fitting surface of All-on-4 fixed prostheses in order to find new strategies for maintaining their hygiene.
MATERIALS AND METHODS: Twenty All-on-4 maxillary fixed prostheses collected from 20 patients, 6 months after delivery, were stained with methylene blue to disclose plaque accumulation at the fitting surfaces of the prostheses. Digital photographs of the fitting surfaces of the prostheses were recorded and processed. The distribution of accumulated plaque was evaluated statistically.
RESULTS: The average percentage of area covered with plaque was 28 ± 8% of the total area of the fitting surface of the prostheses. The fitting surfaces of the prostheses had three times more plaque on the palatal area (52.5 ± 7.33%) than on the buccal area (17.3 ± 7.33%, p < .05). The interimplant proximal areas of the fitting surface covered with plaque were high when the distance between implants was short (r = -0.326, p = .014).
CONCLUSION: These findings suggest that the hygiene of the All-on-4 prostheses could be improved by maximizing the distances between the inserted implants in the jaw, minimizing the prostheses' palatal extension and guiding patients to optimize their oral hygiene practices targeting the palatal area of their prostheses.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  clinical study; fixed implant prosthesis; peri-implantitis; plaque accumulation; prosthesis hygiene

Mesh:

Year:  2014        PMID: 24461161     DOI: 10.1111/cid.12199

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  2 in total

1.  Maxillary Overdenture Retained with an Implant Support CAD-CAM Bar: A 4 Years Follow Up Case.

Authors:  Massimo Corsalini; Daniela Di Venere; Gianluca Stefanachi; Giovannino Muci; Andrea Palminteri; Alessandra Laforgia; Francesco Pettini
Journal:  Open Dent J       Date:  2017-05-31

2.  Comparison of peri-implant submucosal microbiota in arches with zirconia or titanium implant-supported fixed complete dental prostheses: a study protocol for a randomized controlled trial.

Authors:  Pingyi Jia; Jingwen Yang; Zhaoguo Yue; Jianzhang Liu; Qi Liu; Zhongning Liu; Lin Tang; Jianxia Hou
Journal:  Trials       Date:  2020-11-27       Impact factor: 2.279

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.