Literature DB >> 28657669

Does the use of arteriovenous loops increase complications rates in posttraumatic microsurgical lower extremity reconstruction?-A matched-pair analysis.

Arash Momeni1, Michael A Lanni2, Lawrence S Levin3, Stephen J Kovach2.   

Abstract

INTRODUCTION: The use of arteriovenous (AV) loops in microsurgical lower extremity reconstruction is a controversial topic. The objective of the present study was to assess the impact of AV loops on complication rates following microsurgical reconstruction of posttraumatic lower extremity defects. PATIENTS AND METHODS: Patients who underwent free flap coverage of posttraumatic defects in combination with an AV loop (Group 1) were identified and matched for age, body mass index (BMI), tobacco use, defect location, and flap type with patients who underwent reconstruction without vein grafts (Group 2). Outcomes of interest included complication rate and flap loss rate.
RESULTS: Groups 1 and 2 consisted of 10 patients each with a mean age of 51 years (range, 21-79 years) and 47.3 years (range, 22-69 years), respectively (P = 0.596). No differences were noted regarding flap loss (P = 1.0), intraoperative (P = 0.474) or postoperative complication rate [surgical site infection (P = 1.0), bleeding (P = 1.0), delayed wound healing (P = 0.23), dehiscence (P = 0.58), and osseous non-union (P = 1.0)]. Only one flap loss was noted in Group 1. The only differences were increased operative time (P = 0.03) and increased length of stay (P = 0.009) in Group 1.
CONCLUSION: Our results suggest that utilization of vein grafts with creation of AV loops followed by single-stage division and free flap transfer for reconstruction of posttraumatic lower extremity defects achieve reconstructive outcomes similar to those obtained in patients in whom no vein grafts are necessary.
© 2018 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2017        PMID: 28657669     DOI: 10.1002/micr.30197

Source DB:  PubMed          Journal:  Microsurgery        ISSN: 0738-1085            Impact factor:   2.425


  4 in total

Review 1.  Microsurgical Reconstruction of the Lower Extremity.

Authors:  William C Pederson; Luke Grome
Journal:  Semin Plast Surg       Date:  2019-03-08       Impact factor: 2.314

2.  Arteriovenous Loops Enable Free Tissue Transfer With Otherwise Inadequate Local Donor and Recipient Vessels.

Authors:  Mathias Tremp; Carlo M Oranges; Thomas Wolff; Marina Barandun; Ilario Fulco; Henrik Eckardt; Dirk J Schaefer; Daniel F Kalbermatten
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

3.  Arteriovenous Vascular Loop Using a Bifurcated Greater Saphenous Vein.

Authors:  Pedro C Cavadas; Magdalena Baklinska; Alejandro Almoguera-Martinez
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-01-18

4.  Heterogeneous Maturation of Arterio-Venous Fistulas and Loop-Shaped Venous Interposition Grafts: A Histological and 3D Flow Simulation Comparison.

Authors:  Balazs Szabo; Balazs Gasz; Laszlo Adam Fazekas; Adam Varga; Levente Kiss-Papai; Orsolya Matolay; Zsofia Rezsabek; Mohammad W Al-Smadi; Norbert Nemeth
Journal:  Biomedicines       Date:  2022-06-25
  4 in total