Literature DB >> 28650590

Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography.

Alexandre S C Reis1, Camila E S Zangalli1, Ricardo Y Abe1, André L Silva1, Jayme R Vianna2, José Paulo C Vasconcellos1, Vital P Costa1.   

Abstract

PURPOSE: To investigate the reproducibility of Bruch's membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) measurements using spectral domain optical coherence tomography (SD-OCT). Additionally, to investigate the reproducibility of BMO area measurements and fovea to BMO centre (FoBMO) angle.
METHODS: Participants were healthy subjects (n = 30) and patients with glaucoma (n = 26). One eye of each participant was scanned to obtain optic nerve head (24 radial B-scans) and peripapillary (one circular B-scan) images by three independent examiners. Additionally, one examiner imaged each participant three times on the same day. Intra- and interobserver reproducibilities were estimated by within-subject standard deviation (SW) and coefficient of variation (COV). Spearman's rank correlation coefficient was used to test the correlation between the magnitude of the parameter and its standard deviation.
RESULTS: The global BMO-MRW COVs (%) in healthy/glaucoma subjects were 0.87/1.34 and 1.28/3.13 for intra- and interobserver analyses, respectively, and the corresponding global RNFLT figures were 1.50/2.10 and 2.04/2.87. Global mean BMO-MRW and RNFLT showed no correlation with their respective standard deviations. The reproducibilities of BMO area and FoBMO angle were excellent and similar between the groups.
CONCLUSION: The reproducibilities of BMO-MRW, BMO area measurements and FoBMO angle were excellent in both healthy subjects and patients with glaucoma. Bruch's membrane opening minimum rim width (BMO-MRW) reproducibility is comparable to that of RNFLT measurements.
© 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  glaucoma; neuroretinal rim; optic nerve head; optical coherence tomography; reproducibility

Mesh:

Year:  2017        PMID: 28650590     DOI: 10.1111/aos.13464

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  11 in total

1.  Novel area-based optic nerve head parameter to distinguish glaucoma from non-glaucomatous retinal nerve fiber layer defect in branch retinal vein occlusion.

Authors:  Yerim An; Sung Pyo Park; Kyeong Ik Na
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-08-14       Impact factor: 3.117

2.  A Deep Learning Algorithm to Quantify Neuroretinal Rim Loss From Optic Disc Photographs.

Authors:  Atalie C Thompson; Alessandro A Jammal; Felipe A Medeiros
Journal:  Am J Ophthalmol       Date:  2019-01-26       Impact factor: 5.258

3.  Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in a Brazilian population of healthy subjects.

Authors:  Camila S Zangalli; Jayme R Vianna; Alexandre S C Reis; Jamil Miguel-Neto; Claude F Burgoyne; Balwantray C Chauhan; Vital P Costa
Journal:  PLoS One       Date:  2018-12-18       Impact factor: 3.240

4.  Structure-function relationships in glaucoma using enhanced depth imaging optical coherence tomography-derived parameters: a cross-sectional observational study.

Authors:  Flavio S Lopes; Igor Matsubara; Izabela Almeida; Syril K Dorairaj; Roberto M Vessani; Augusto Paranhos; Tiago S Prata
Journal:  BMC Ophthalmol       Date:  2019-02-15       Impact factor: 2.209

5.  Longitudinal In Vivo Changes in Radial Peripapillary Capillaries and Optic Nerve Head Structure in Non-Human Primates With Early Experimental Glaucoma.

Authors:  Gwen Musial; Suman Adhikari; Hanieh Mirhajianmoghadam; Hope M Queener; Alexander W Schill; Nimesh B Patel; Jason Porter
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-01-03       Impact factor: 4.799

6.  Changes of Neuroretinal Rim and Retinal Nerve Fiber Layer Thickness Assessed by Optical Coherence Tomography After Filtration Surgery in Glaucomatous Eyes.

Authors:  Susanna Friederike Koenig; Christoph Wolfgang Hirneiss
Journal:  Clin Ophthalmol       Date:  2021-06-03

7.  The impact of optic nerve and related characteristics on disc area measurements derived from different imaging techniques.

Authors:  Michael Yapp; George Rennie; Michael P Hennessy; Michael Kalloniatis; Barbara Zangerl
Journal:  PLoS One       Date:  2018-01-17       Impact factor: 3.240

Review 8.  Utility of combining spectral domain optical coherence tomography structural parameters for the diagnosis of early Glaucoma: a mini-review.

Authors:  Jean-Claude Mwanza; Joshua L Warren; Donald L Budenz
Journal:  Eye Vis (Lond)       Date:  2018-04-15

9.  The Shape of Posterior Sclera as a Biometric Signature in Open-angle Glaucoma: An Intereye Comparison Study.

Authors:  Yong Chan Kim; Yong Ho Koo; Hyung Bin Hwang; Kui Dong Kang
Journal:  J Glaucoma       Date:  2020-10       Impact factor: 2.290

10.  Disc Hemorrhages Are Associated With Localized Three-Dimensional Neuroretinal Rim Thickness Progression in Open-Angle Glaucoma.

Authors:  Milica A Margeta; Kitiya Ratanawongphaibul; Edem Tsikata; Michele Zemplenyi; Courtney L Ondeck; Janice Kim; Anne L Coleman; Fei Yu; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2021-06-29       Impact factor: 5.258

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.