Literature DB >> 28648702

A Dual-Pivot Pattern Simulating Native Knee Kinematics Optimizes Functional Outcomes After Total Knee Arthroplasty.

R Michael Meneghini1, Evan R Deckard2, Marshall K Ishmael2, Mary Ziemba-Davis2.   

Abstract

BACKGROUND: Few studies on kinematics correlate patterns to functional outcomes after total knee arthroplasty (TKA). The purpose of this study was to determine if lateral pivot motion in early flexion and medial pivot in high flexion, simulating native knee kinematics, produces superior clinical outcomes. A second objective was to determine if specific kinematic patterns produce superior outcomes.
METHODS: One hundred twenty consecutive TKAs were performed using sensor trials to record intraoperative knee kinematics. Lateral and medial pivot pattern designations were based on the center of rotation within 3 flexion zones: 0°-45° (early), 45°-90°, and 90° to full flexion (late). Knee Society Scores, pain scores, and patient satisfaction were analyzed in relation to kinematic patterns.
RESULTS: Knee Society function scores were higher in TKAs with early lateral pivot/late medial pivot intraoperative kinematics compared to all other kinematic patterns (P = .018), and there was a greater decrease in the proportion who reported that their knee never feels normal (P = .011). Early lateral/late medial pivot had greater function scores at 1-year (P < .001) and improvement from preoperative baseline (P = .008) compared to those with the least ideal pattern. All patients with the most ideal pattern compared to none of the least ideal pattern reported they were very satisfied (P = .003).
CONCLUSION: Patients with an intraoperative early lateral pivot pattern followed by medial pivot motion in later flexion, reported higher functional outcome scores along with higher overall patient satisfaction. Replicating the dual-pivot kinematic pattern observed in native knees may improve function and satisfaction after TKA.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  kinematics; lateral-pivot; medial-pivot; patient-reported outcomes; sensors; total knee arthroplasty

Mesh:

Year:  2017        PMID: 28648702     DOI: 10.1016/j.arth.2017.04.050

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Knee kinematics in bi-cruciate stabilized total knee arthroplasty during squatting and stair-climbing activities.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Hirotaka Gondo; Yifeng Wang; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Hideki Mizu-Uchi; Yukio Akasaki; Yasuharu Nakashima
Journal:  J Orthop       Date:  2018-05-07

2.  In vivo kinematics and ligamentous function of the knee during weight-bearing flexion: an investigation on mid-range flexion of the knee.

Authors:  Zhitao Rao; Chaochao Zhou; Willem A Kernkamp; Timothy E Foster; Hany S Bedair; Guoan Li
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-10       Impact factor: 4.342

3.  In vivo kinematics of gait in posterior-stabilized and bicruciate-stabilized total knee arthroplasties using image-matching techniques.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Yifeng Wang; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Hideki Mizu-Uchi; Yukio Akasaki; Yasuharu Nakashima
Journal:  Int Orthop       Date:  2018-04-05       Impact factor: 3.075

4.  Pain, balance, and mobility in people 1 year after total knee arthroplasty: a non-randomized cross-sectional pilot study contrasting posterior-stabilized and medial-pivot designs.

Authors:  Cathy W T Lo; Matthew A Brodie; William W N Tsang; Stephen R Lord; Chun-Hoi Yan; Arnold Y L Wong
Journal:  Pilot Feasibility Stud       Date:  2022-06-28

Review 5.  Biomechanics and Outcomes of Modern Tibial Polyethylene Inserts.

Authors:  Darshan Shah; Taylor Bates; Craig Kampfer; Donald Hope
Journal:  Curr Rev Musculoskelet Med       Date:  2022-04-06

6.  Which one restores in vivo knee kinematics effectively-medial or lateral pivot?

Authors:  Sahil Batra; Pon Aravindhan A Sugumar; Vijay Kumar; Rajesh Malhotra
Journal:  J Clin Orthop Trauma       Date:  2020-08-21

7.  Tibial baseplate position and posterior cruciate ligament status impact patient-reported outcomes in conforming dual-pivot bearing total knee arthroplasty.

Authors:  Joseph A Madden; Payton K Arnold; Leonard T Buller; Evan R Deckard; R Michael Meneghini
Journal:  Arthroplast Today       Date:  2021-10-04

8.  Tibiofemoral Contact Forces Influence Intraoperative Kinematic Pivot Pattern Dependent on Posterior Cruciate Ligament Resection in Primary Total Knee Arthroplasty.

Authors:  Evan R Deckard; Mary Ziemba-Davis; R Michael Meneghini
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2022-04-05

9.  Kinematic Alignment in Total Knee Arthroplasty Reduces Polyethylene Contact Pressure by Increasing the Contact Area, When Compared to Mechanical Alignment-A Finite Element Analysis.

Authors:  Antonio Klasan; Andreas Kapshammer; Veronika Miron; Zoltan Major
Journal:  J Pers Med       Date:  2022-08-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.