| Literature DB >> 28639113 |
Nicolai Cernean1, Florentino Serranheira1,2,3, Pedro Gonçalves1, Cláudia Sá Dos Reis4,5,6.
Abstract
OBJECTIVES: To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs).Entities:
Keywords: Ergonomics; Mammography; Posture; Radiographer; Work-related disorders
Year: 2017 PMID: 28639113 PMCID: PMC5519499 DOI: 10.1007/s13244-017-0560-7
Source DB: PubMed Journal: Insights Imaging ISSN: 1869-4101
Reference values for postural assessment (Standard BS EN 1005–4: 2005)
| Norma BSEN 1005–4: 2005 + A1: 2008 | |||
|---|---|---|---|
| Anatomical area/posture | Acceptable | Conditionally acceptable | Not acceptable |
| Trunk forward bending | 0–20° | 20–60° | >60° |
| Upper arm flexion | 0–20° | 20–60° | >60° |
| Upper arm abduction | 0–20° | 20–60° | |
| Head/neck upward/downward bending | −40 to 0° | - | 0–40° |
Simulated contexts during the breast positioning in craniocaudal (CC) and mediolateral oblique (MLO), without and with postural alternatives considering the radiographer and the patient
| Context | Postural alternatives for the radiographer | Postural alternatives for the patient | Simulated breast positioning |
|---|---|---|---|
| Anthropometric combination radiographer/ | None | Patient on a | CC |
| None | Patient seated on a stool | CC | |
| None | Patient on a | MLO | |
| Radiographer seated on a stool | None | MLO | |
| Anthropometric combination radiographer/ | None | Patient on a | CC |
| None | Patient on a | MLO | |
| Radiographer seated on a stool | None | MLO | |
| Anthropometric combination radiographer/ | Radiographer on a | None | CC |
| None | Patient seated on a stool | CC | |
| None | Patient on a | MLO | |
| Radiographer seated on a stool | Patient seated on a stool | MLO |
Fig. 1CC breast positioning: a and c radiographer postures without intervention; b and d alternative postures when the radiographer and patient have identical statures
Fig. 2MLO breast positioning: a and c radiographer postures without intervention; b and d alternative postures when the radiographer and patient have identical statures
Fig. 3CC breast positioning: a and c radiographer postures without intervention; b and d alternative postures when the radiographer smaller than the patient
Fig. 4MLO breast positioning: a and c radiographer postures without intervention; b and d alternative postures when the radiographer smaller than the patient
Fig. 5CC breast positioning: a and c radiographer postures without intervention; b and d alternative postures when the radiographer is taller than the patient
Fig. 6MLO breast positioning: a and c radiographer postures without intervention; b and d alternative postures when the radiographer is taller than the patient
Angles measured on the radiographer during CC breast positioning (radiographer and patient with identical the stature)
| Without intervention | Patient on a | Patient seated on a stool | |||||
|---|---|---|---|---|---|---|---|
| Posture | Breast positioning | Measured angle | Classification | Measured angle | Classification | Measured angle | Classification |
| Trunk | CC | 0° | Acceptable | 0° | Acceptable | 0° | Acceptable |
| Arm flexion | CC | 60° | Conditionally acceptable | 38° | Conditionally acceptable | 9° | Acceptable |
| Arm abduction | CC | 35° | Conditionally acceptable | 37° | Conditionally acceptable | 29° | Conditionally acceptable |
| Head/neck | CC | 26° | Acceptable | 20° | Acceptable | 37° | Acceptable |
Angles measured on radiographer during MLO breast positioning (radiographer and patient with identical the stature)
| Without intervention | Patient on a | Radiographer seated on a stool | |||||
|---|---|---|---|---|---|---|---|
| Posture | Breast positioning | Measured angle | Classification | Measured angle | Classification | Measured angle | Classification |
| Trunk | MLO | 35° | Conditionally acceptable | 26° | Conditionally acceptable | 0° | Acceptable |
| Arm flexion | MLO | 93° | Not acceptable | 82° | Not acceptable | 59° | Conditionally acceptable |
| Arm abduction | MLO | 80° | Not acceptable | 82° | Not acceptable | 79° | Not acceptable |
| Neck/head | MLO | −5° | Not acceptable | −7° | Not acceptable | 0° | Acceptable |
Angles measured on the radiographer during CC breast positioning (radiographer smaller than the patient)
| Without intervention | Patient seated in a stool | Radiographer on | |||||
|---|---|---|---|---|---|---|---|
| Posture | Breast positioning | Measured angle | Classification | Measured angle | Classification | Measured angle | Classification |
| Trunk | CC | 7° | Acceptable | 7° | Acceptable | 8° | Acceptable |
| Arm flexion | CC | 64° | Not acceptable | 36° | Conditionally acceptable | 41° | Conditionally acceptable |
| Arm flexion | CC | 70° | Not acceptable | 62° | Not acceptable | 42° | Conditionally acceptable |
| Head/neck | CC | 21° | Acceptable | 4° | Acceptable | 24° | Acceptable |
MLO breast positioning: postures for radiographer smaller than the patient without and with postural interventions
| Without intervention | Radiographer and patient seated in a stool | Patient on a | |||||
|---|---|---|---|---|---|---|---|
| Posture | Breast positioning | Measured angle | Classification | Measured angle | Classification | Measured angle | Classification |
| Trunk | MLO | 6° | Acceptable | 30° | Acceptable | 9° | Conditionally acceptable |
| Arm flexion | MLO | 71° | Not acceptable | 74° | Not acceptable | 69° | Not acceptable |
| Arm abduction | MLO | 80° | Not acceptable | 66° | Not acceptable | 81° | Not acceptable |
| Head/neck | MLO | 16° | Acceptable | 4° | Acceptable | 0° | Acceptable |
Angles measured on the radiographer performing CC breast positioning (radiographer taller than the patient)
| Without intervention | Patient on a | ||||
|---|---|---|---|---|---|
| Posture | Breast positioning | Measured angle | Classification | Measured angle | Classification |
| Trunk | CC | 4° | Acceptable | 3° | Acceptable |
| Arm flexion | CC | 27° | Conditionally acceptable | 33° | Conditionally acceptable |
| Arm abduction | CC | 36° | Conditionally acceptable | 49° | Conditionally acceptable |
| Head/neck | CC | 32° | Acceptable | 18° | Acceptable |
Angles measured on radiographer performing MLO breast positioning (radiographer taller than the patient)
| Without intervention | Radiographer seated | Patient on a | |||||
|---|---|---|---|---|---|---|---|
| Posture | Breast positioning | Measured angle | Classification | Measured angle | Classification | Measured angle | Classification |
| Trunk | MLO | 72° | Not acceptable | 51° | Conditionally acceptable | 14° | Acceptable |
| Arm flexion | MLO | 139° | Not acceptable | 128° | Not acceptable | 60° | Conditionally acceptable |
| Arm abduction | MLO | 120° | Not acceptable | 95° | Not acceptable | 99° | Not acceptable |
| Head/neck | MLO | −24° | Not acceptable | −18° | Not acceptable | 0° | Acceptable |