Literature DB >> 28626630

Arthroscopic Removal of Proximal Humerus Plates in Chronic Post-traumatic Shoulder Stiffness.

Deepak N Bhatia1.   

Abstract

Proximal humerus fracture fixation may be complicated by persistent postsurgical stiffness or implant-related problems. Arthroscopic plate removal is a cosmetic and functionally beneficial procedure; however, the procedure is technically difficult in the presence of severe subdeltoid scarring. The technique described here shows an arthroscopic subdeltoid adhesiolysis and proximal humerus plate removal using systematic access to 5 regions of screw positions on the plate. After initial glenohumeral adhesiolysis, a thorough subacromial and subdeltoid bursectomy is performed. The axillary nerve and deltoid are retracted via an anterosuperolateral portal, and a posterolateral portal is used for panoramic viewing along the plate length. Lateral portals are placed above and below the axillary nerve, and these are used for screw removal. Finally, the plate is removed via a 1-inch incision along the previous surgical scar. The technique is cosmetic and minimally invasive, and early rehabilitation restores range of motion and strength. Technical tips for safe dissection in the scarred subdeltoid space and guidelines for protection of neurovascular structures are presented.

Entities:  

Year:  2017        PMID: 28626630      PMCID: PMC5462709          DOI: 10.1016/j.eats.2016.10.014

Source DB:  PubMed          Journal:  Arthrosc Tech        ISSN: 2212-6287


  6 in total

1.  Arthroscopic removal of proximal humerus locking plates.

Authors:  Joshua S Dines; Carolyn M Hettrich; Bryan T Kelly; Felix H Savoie; Dean G Lorich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-28       Impact factor: 4.342

2.  Fixed-angle locking proximal humerus plate: an evaluation of functional results and implant-related outcomes.

Authors:  Ponnaren Pak; Kevin Eng; Richard S Page
Journal:  ANZ J Surg       Date:  2013-09-05       Impact factor: 1.872

3.  Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings.

Authors:  Jan Christoph Katthagen; Daniel Hennecke; Gunnar Jensen; Alexander Ellwein; Christine Voigt; Helmut Lill
Journal:  Arthroscopy       Date:  2014-06-14       Impact factor: 4.772

4.  Arthroscopic Removal of Symptomatic Proximal Humerus Locking Plates With Bone-Void Filler Augmentation.

Authors:  Pramod B Voleti; Christopher L Camp; Alec L Sinatro; Joshua S Dines
Journal:  Arthrosc Tech       Date:  2016-04-11

5.  The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures.

Authors:  Ali Maqdes; Bruno Levy; Shahnaz Klouche; Philippe Hardy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-09       Impact factor: 4.342

6.  Elective implant removal in symptomatic patients after internal fixation of proximal humerus fractures improves clinical outcome.

Authors:  Yves P Acklin; Christian Michelitsch; Christoph Sommer
Journal:  BMC Musculoskelet Disord       Date:  2016-03-10       Impact factor: 2.362

  6 in total
  3 in total

1.  Selective Glenohumeral external rotation deficit - sequelae of post-ORIF deltoid adhesions after treatment of the proximal humerus fracture.

Authors:  Michał Waszczykowski; Jarosław Fabiś
Journal:  BMC Musculoskelet Disord       Date:  2020-09-22       Impact factor: 2.362

2.  Outcomes of Mini-Invasive Arthroscopic Arthrolysis Combined with Locking Screw and/or Intramedullary Nail Extraction after Osteosynthesis of the Proximal Humerus Fracture.

Authors:  Roman Madeja; Jana Pometlová; Roman Brzóska; Jiří Voves; Lubor Bialy; Leopold Pleva; Jan Stránský; Adéla Vrtková; Jaroslav Janošek; Kristýna Čabanová
Journal:  J Clin Med       Date:  2022-01-12       Impact factor: 4.241

3.  Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?

Authors:  Beom-Soo Kim; Du-Han Kim; Jung-Hoon Choi; Byung-Chan Choi; Chul-Hyun Cho
Journal:  Medicina (Kaunas)       Date:  2022-03-04       Impact factor: 2.430

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.