Literature DB >> 24003839

Fixed-angle locking proximal humerus plate: an evaluation of functional results and implant-related outcomes.

Ponnaren Pak1, Kevin Eng, Richard S Page.   

Abstract

BACKGROUND: Displaced and unstable proximal humeral fractures are challenging injuries to treat. Proximal humeral locking plates are a recent development for the treatment of these complex fractures.
METHODS: Retrospective analysis of 23 patients with 23 proximal humeral fractures treated with the Synthes locking proximal humerus plate. These were Neer two-, three- and four-part fractures. Follow-up was at a mean of 22 months and included clinical assessment using the Constant score (CS) and the Short Form-12 health questionnaire. Radiographic assessment was performed to assess implant-related complication in relation to the initial fracture pattern and the presence of adequate medial support.
RESULTS: The mean CS for all patients was 60.4 (range, 29-85). The mean adjusted CS was 82% (range, 30-117), active forward flexion 127 degrees and the active abduction 115 degrees. Initial fracture pattern, the presence or absence of adequate medial support and age did not significantly influence the clinical scores. Complications included one infection, two cases of avascular necrosis, two cases of varus collapse with screw penetration and one non-union. The overall reoperation rate was 26%. There was an increased rate of complications in those with inadequate medial support (P = 0.0183) and a trend to higher complication rates in four-part fractures.
CONCLUSION: Using the locking proximal humerus plate for the treatment of proximal humeral fractures is an acceptable procedure with comparable outcomes with historical controls, but with a complication rate of 30%. More important than implant selection, however, is the ability to achieve a stable reduction with calcar support.
© 2013 Royal Australasian College of Surgeons.

Entities:  

Keywords:  complications; locking plate; outcomes; proximal humerus fracture

Mesh:

Year:  2013        PMID: 24003839     DOI: 10.1111/ans.12370

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  5 in total

1.  Arthroscopic Removal of Proximal Humerus Plates in Chronic Post-traumatic Shoulder Stiffness.

Authors:  Deepak N Bhatia
Journal:  Arthrosc Tech       Date:  2017-03-27

2.  Medial cortical positive support: A key factor for the postoperative stability of proximal humerus fractures.

Authors:  Xuchao Shi; Mingyuan Han; Bo Dai
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

3.  Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures.

Authors:  Chih-Kun Hsiao; Yi-Jung Tsai; Cheng-Yo Yen; Cheng-Hung Lee; Teng-Yao Yang; Yuan-Kun Tu
Journal:  BMC Musculoskelet Disord       Date:  2017-02-02       Impact factor: 2.362

Review 4.  Complications Associated with Locking Plate of Proximal Humerus Fractures.

Authors:  Venkat Kavuri; Blake Bowden; Neil Kumar; Doug Cerynik
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

5.  The Proximal Humerus Outcome Score at One Year (POSY) Predicts Which Patients Have Poor Functional Outcomes Following Operative Fixation of Proximal Humerus Fractures.

Authors:  Nina D Fisher; Adam Driesman; Hesham Saleh; Kenneth A Egol; Sanjit R Konda
Journal:  Cureus       Date:  2022-07-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.