Literature DB >> 28622439

Clinical effectiveness of a Bayesian algorithm for the diagnosis and management of heparin-induced thrombocytopenia.

R A Raschke1,2, T Gallo1, S C Curry1,3, T Whiting2, A Padilla-Jones4, T E Warkentin5, A Puri6.   

Abstract

Essentials We previously published a diagnostic algorithm for heparin-induced thrombocytopenia (HIT). In this study, we validated the algorithm in an independent large healthcare system. The accuracy was 98%, sensitivity 82% and specificity 99%. The algorithm has potential to improve accuracy and efficiency in the diagnosis of HIT.
SUMMARY: Background Heparin-induced thrombocytopenia (HIT) is a life-threatening drug reaction caused by antiplatelet factor 4/heparin (anti-PF4/H) antibodies. Commercial tests to detect these antibodies have suboptimal operating characteristics. We previously developed a diagnostic algorithm for HIT that incorporated 'four Ts' (4Ts) scoring and a stratified interpretation of an anti-PF4/H enzyme-linked immunosorbent assay (ELISA) and yielded a discriminant accuracy of 0.97 (95% confidence interval [CI], 0.93-1.00). Objectives The purpose of this study was to validate the algorithm in an independent patient population and quantitate effects that algorithm adherence could have on clinical care. Methods A retrospective cohort comprised patients who had undergone anti-PF4/H ELISA and serotonin release assay (SRA) testing in our healthcare system from 2010 to 2014. We determined the algorithm recommendation for each patient, compared recommendations with the clinical care received, and enumerated consequences of discrepancies. Operating characteristics were calculated for algorithm recommendations using SRA as the reference standard. Results Analysis was performed on 181 patients, 10 of whom were ruled in for HIT. The algorithm accurately stratified 98% of patients (95% CI, 95-99%), ruling out HIT in 158, ruling in HIT in 10 and recommending an SRA in 13 patients. Algorithm adherence would have obviated 165 SRAs and prevented 30 courses of unnecessary antithrombotic therapy for HIT. Diagnostic sensitivity was 0.82 (95% CI, 0.48-0.98), specificity 0.99 (95% CI, 0.97-1.00), PPV 0.90 (95% CI, 0.56-0.99) and NPV 0.99 (95% CI, 0.96-1.00). Conclusions An algorithm incorporating 4Ts scoring and a stratified interpretation of the anti-PF4/H ELISA has good operating characteristics and the potential to improve management of suspected HIT patients.
© 2017 International Society on Thrombosis and Haemostasis.

Entities:  

Keywords:  algorithms; anticoagulants; enzyme-linked immunosorbent assay; heparin; thrombocytopenia

Mesh:

Substances:

Year:  2017        PMID: 28622439     DOI: 10.1111/jth.13758

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  3 in total

1.  Diagnosing HIT: the need for speed.

Authors:  Adam Cuker; Douglas B Cines
Journal:  Blood       Date:  2020-04-02       Impact factor: 25.476

Review 2.  Heparin-Induced Thrombocytopenia: A Review of New Concepts in Pathogenesis, Diagnosis, and Management.

Authors:  Matteo Marchetti; Maxime G Zermatten; Debora Bertaggia Calderara; Alessandro Aliotta; Lorenzo Alberio
Journal:  J Clin Med       Date:  2021-02-10       Impact factor: 4.241

3.  Functional Flow Cytometric Assay for Reliable and Convenient Heparin-Induced Thrombocytopenia Diagnosis in Daily Practice.

Authors:  Brigitte Tardy-Poncet; Aurélie Montmartin; Michele Piot; Martine Alhenc-Gelas; Philippe Nguyen; Ismail Elalamy; Andreas Greinacher; Emmanuel De Maistre; Dominique Lasne; Marie-Hélène Horellou; Grégoire Le Gal; Thomas Lecompte; Bernard Tardy
Journal:  Biomedicines       Date:  2021-03-25