| Literature DB >> 28608162 |
Anouk M Barendregt1,2, E Charlotte van Gulik3,4, Cristina Lavini3, Charlotte M Nusman3, J Merlijn van den Berg4, Dieneke Schonenberg-Meinema4, Koert M Dolman5,6,7, Taco W Kuijpers4, Robert Hemke3, Mario Maas3.
Abstract
OBJECTIVES: To compare dynamic-contrast-enhanced MRI (DCE) and diffusion-weighted imaging (DWI) in quantifying synovial inflammation in juvenile idiopathic arthritis (JIA).Entities:
Keywords: Arthritis; Diffusion magnetic resonance imaging; Juvenile arthritis; Knee joint; Magnetic resonance imaging
Mesh:
Substances:
Year: 2017 PMID: 28608162 PMCID: PMC5635098 DOI: 10.1007/s00330-017-4876-y
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315
MRI scanning protocol. A dedicated knee coil was used. Patients were placed in supine position with their knee centrally located in the coil and the eight listed sequences were acquired chronologically. During the sixth sequence (DCE), gadolinium-based contrast agent was administered
| IV Gd | Repetition time (ms) | Echo time (ms) | Flip angle | Field of view | Voxel size (mm) | Slice thickness | Recon. | TSE factor | NSA | |
|---|---|---|---|---|---|---|---|---|---|---|
| Sagittal T2 SPIR | - | 2800-4500 | 50 | 90° | 150 × 150 × 92 | 0.5 × 0.6 | 4 | 445 | 14 | 3 |
| Coronal T2 SPIR | - | 2800-4500 | 60 | 90° | 150 × 150 × 92 | 0.5 × 0.6 | 4 | 480 | 13 | 3 |
| Axial T2 SPIR | - | 2800-4500 | 50 | 90° | 150 × 150 × 104.8 | 0.5 × 0.55 | 4 | 480 | 15 | 3 |
| Axial T2 EPI DWI | - | 6282-8164 | 98-114 | 90° | 180 × 160 × 63 | 1 × 1 | 3.5 | 256 | - | 8 |
| Sagittal T1 TSE | - | 450-650 | 10 | 90° | 150 × 150 × 92 | 0.45 × 0.63 | 4 | 480 | 6 | 3 |
| Axial T1GE DCE | + | 9-10 | 6.9 | 30° | 180 × 160 × 63 | 1 × 1 | 3.5 | 256 | 25 (TFE) | 1 |
| Sagittal T1 TSE | + | 450-650 | 10 | 90° | 150 × 150 × 92 | 0.45 × 0.63 | 4 | 480 | 6 | 3 |
| Axial T1 SPIR | + | 400-750 | 10 | 90° | 150 × 150 × 104.8 | 0.55 × 0.77 | 4 | 480 | 6 | 2 |
IV Gd = intravenous GBCA injection,, Recon. = reconstruction, NSA = number of signal averages, TSE = turbo spin echo, TFE = turbo field echo, SPIR = spectral presaturation inversion recovery, EPI = echo planar imaging, GE = gradient echo.
Fig. 1MRI example of two patients using a sagittal T1 pre- and post-contrast image and an axial T1 SPIR post-contrast image. MRI-active disease: the upper row represents an 11-year old boy with JIA who had synovial hypertrophy in multiple knee compartments, resulting in a total JAMRIS (Juvenile Arthritis MRI Scoring System) synovial hypertrophy (SH) score of 8. Note the enhancing and thickened synovial membrane in both the sagittal T1 post-contrast slice and the axial T1 SPIR. MRI-inactive disease: the lower row represents a 12-year old girl with JIA with no synovial hypertrophy in the knee (JAMRIS SH 0)
Fig. 2Visualisation of the seven-time intensity curve (TIC) shapes that were used in the TIC shape analysis. A detailed explanation of the TIC shape analysis can be found in references [25, 26]
Patient characteristics of the MRI-inactive and -active JIA patients. Non-parametric tests were used to study homogeneity of the two groups. P-values for all patient characteristics are displayed in the last column. Note that no statistically significant differences were seen between MRI-inactive and -active JIA patients
| Group 1 MRI-inactive JIA ( | Group 2 MRI-active JIA ( |
| |
|---|---|---|---|
| % Females (no. of females) | 77% (13) | 67% (12) | 0.711a |
| Median age in months (IQR) | 163 (143-196) | 150 (129-177) | 0.13b |
| % ILAR subtype (no.) | |||
| Oligo-persistent | 53% (9) | 56% (10) | 0.88c |
| Oligo-extended | 6% (1) | 6% (1) | 1.00a |
| Poly-RF + | 12% (2) | 0% (0) | 0.23a |
| Poly-RF – | 24% (4) | 28% (5) | 1.00a |
| ERA | 0% (0) | 11% (2) | 0.49a |
| Psoriatic | 6% (1) | 0% (0) | 0.49a |
| Median ESR (IQR) | 6 (2-8) | 5 (2-8) | 0.48b |
| Median CRP (IQR) | 0.4 (0.0-3.6) | 0.3 (0-0.5) | 0.29b |
| Median number of active joints (IQR) | 0 (0-4.0) | 1 (0.75-1.25) | 0.55b |
Median Physician Global Assessment of disease activity (0-100) (IQR) | 4 (0-18) | 11 (7-21) | 0.08b |
IQR = interquartile range, ILAR = International League Against Rheumatism, RF = rheumatoid factor, ERA = enthesis-related arthritis, ESR = erythrocyte sedimentation rate, CRP = C-reactive protein
aFisher’s exact test
bMann-Whitney U test
cPearson chi-square test
Fig. 3Example of a T1 dynamic contrast-enhanced image and parametric maps (maximum enhancement (ME) and apparent diffusion coefficient (ADC)) of an MRI-active JIA patient (upper row) and MRI-inactive JIA patient (lower row) with demonstration of region of interest (ROI) placement. Arrows point to the ROIs. ROIs were placed in synovial tissue. Joint effusion (if present) was not included in the ROI, as can be seen in the T1 DCE image of the 11-year old boy with MRI-active JIA
Median values of DCE parameters and ADC in patients with MRI-inactive and -active JIA. Interquartile range is given in between brackets. The 95% confidence interval of the difference between medians (MRI-active versus MRI-inactive JIA) is given in the third column. The associated p-value of the difference between the medians as calculated by the Mann-Whitney U test is listed in the last column. *Statistically significant correlation (p-value < 0.05)
| Variable | Median MRI-inactive JIA (IQR) | Median MRI-active JIA (IQR) | 95% CI of difference between medians |
|
|---|---|---|---|---|
| Maximum enhancement | 0.39 (0.30-0.62) | 0.95 (0.70-1.57) | 0.32, 0.88 | 0.000* |
| Maximum initial slope | 20.80 (18.96-25.19) | 29.40 (21.57-45.99) | 2.56, 21.14 | 0.002* |
| Time to peak | 16.50 (12.55-20.25) | 20.00 (17.90-21.40) | 0.94, 6.17 | 0.005* |
| % TIC 2 shapes | 54 (41-70) | 61 (53-72) | -5, 21 | 0.195 |
| % TIC 3 shapes | 3 (1-5) | 8 (1-32) | 0.2, 26 | 0.062 |
| % TIC 4 shapes | 4 (1-10) | 2 (1-5) | -5, 0.5 | 0.195 |
| % TIC 5 shapes | 9 (6-15) | 3 (2-5) | -11, -3 | 0.000* |
| Apparent diffusion coefficient | 1.25 × 103 (1.06-1.39) | 1.49 × 103 (1.36-1.78) | 0.11, 0.53 | 0.001* |
TIC = time intensity curve, IQR = interquartile range
Fig. 4Boxplots of dynamic contrast-enhanced (DCE) and diffusion-weighted imaging (DWI) parameters that were significantly different in MRI-inactive JIA when compared to MRI-active JIA. The y-axis displays a DCE or DWI parameter (ME, MIS, TTP, TIC5 or ADC). The x-axis is divided in two: first, MRI-inactive patients are displayed (filled circles); second patients with MRI-active JIA indicated by a grey, open square. *= p-value < 0.05
Fig. 5Scatter plot displaying the correlation between dynamic contrast-enhanced (DCE) parameters and apparent diffusion coefficient (ADC) in patients with MRI-inactive JIA. The y-axis represents ADC in mm2/s; the x-axis displays the DCE parameters (ME, TTP and % of TIC 4 shapes). Correlation coefficient 'r' and the associated p-value are displayed within the right corner of each scatter plot. Only statistically significant correlations are shown
Fig. 6Scatter plot displaying correlation between the dynamic contrast-enhanced (DCE) parameters and apparent diffusion coefficient (ADC) in all patients (MRI-inactive and -active JIA). The y-axis represents ADC in mm2/s; the x-axis displays the DCE parameters (ME, MIS and % of TIC 5 shapes). MRI-inactive patients are represented by filled circles, MRI-active patients by a grey, open square. Correlation coefficient 'r' and the associated p-value are displayed within the right corner of each scatter plot. Only statistically significant correlations are shown
Correlation of all DCE parameters with ADC, analysed with all patients together (MRI-inactive and -active JIA) and in MRI-inactive and -active JIA separately. Correlation coefficient r is given, as well as the associated p-value. *Statistically significant correlation (p-value < 0.05)
| Variable | ‘ |
| ‘ |
| ‘ |
|
|---|---|---|---|---|---|---|
| Maximum enhancement | 0.62 | 0.000* | 0.49 | 0.048* | 0.39 | 0.106 |
| Maximum initial slope | 0.45 | 0.007* | 0.20 | 0.451 | 0.29 | 0.250 |
| Time to peak | 0.33 | 0.056 | 0.50 | 0.043* | -0.33 | 0.184 |
| % TIC 2 shapes | 0.28 | 0.103 | 0.46 | 0.064 | 0.06 | 0.826 |
| % TIC 3 shapes | 0.20 | 0.247 | -0.21 | 0.411 | 0.10 | 0.705 |
| % TIC 4 shapes | -0.17 | 0.335 | -0.55 | 0.022* | 0.36 | 0.143 |
| % TIC 5 shapes | -0.51 | 0.002* | -0.32 | 0.213 | -0.27 | 0.278 |
TIC = time intensity curve
Intra-class correlation coefficient (ICC) of first and second ROI measurements for all DCE parameters to assess the reliability of the region of interest (ROI) drawing. Within brackets, the 95% confidence interval (CI) of the ICC is given. The last column represents the p-value of the found correlation. *Statistically significant correlation (p-value < 0.05)
| Variable | ICC (95% CI) |
|
|---|---|---|
| Maximum enhancement | 0.86 (0.31-0.97) | 0.011* |
| Maximum initial slope | 0.95 (0.75-0.99) | 0.001* |
| Time to peak | 0.41 (-2.85-0.89) | 0.269 |
| % TIC 2 shapes | 0.58 (-0.75-0.91) | 0.127 |
| % TIC 3 shapes | 0.98 (0.89-1.00) | 0.000* |
| % TIC 4 shapes | 0.85 (0.17-0.97) | 0.016* |
| % TIC 5 shapes | 0.80 (0.11-0.96) | 0.024* |
| Apparent diffusion coefficient | 0.86 (0.21-0.97) | 0.014* |
ICC = intra-class correlation coefficient,, IC = confidence interval, TIC = time intensity curve