Literature DB >> 28602323

Bifocal nondiffractive intraocular lens for enhanced depth of focus in correcting presbyopia: Clinical evaluation.

Efstathios Vounotrypidis1, Raphael Diener1, Christian Wertheimer1, Thomas Kreutzer1, Armin Wolf1, Siegfried Priglinger1, Wolfgang J Mayer2.   

Abstract

PURPOSE: To assess the clinical outcomes and patient satisfaction after bilateral cataract surgery with implantation of a bifocal refractive enhanced depth of focus intraocular lens (IOL) with a low near addition (add).
SETTING: Department of Ophthalmology, Ludwig-Maximilians-University Munich, Munich, Germany.
DESIGN: Prospective longitudinal case series.
METHODS: Eyes with bilateral age-related cataract and corneal astigmatism of less than 1.0 diopter (D) had standard microincision cataract surgery with implantation of a bifocal nondiffractive shape-segmented enhanced depth of focus IOL (Lentis Comfort, LS-313 MF15). The corrected and uncorrected (UDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, defocus, corneal astigmatism, spectacle independence, contrast sensitivity, rotational stability, photic phenomena, and patient satisfaction were evaluated over a 3-month follow-up.
RESULTS: The study comprised 22 patients (44 eyes). The mean postoperative manifest spherical equivalent was -0.10 D ± 0.58 (SD), resulting in a mean UDVA of 0.07 ± 0.10 logMAR, mean UIVA of 0.21 ± 0.15 logarithm of minimum angle of resolution (logMAR), and mean UNVA of 0.53 ± 0.15 logMAR. Binocular UDVA was 0.01 ± 0.08 logMAR. The best reading distance was 0.46 ± 0.09 m. More than 95% of patients were satisfied with their visual acuity, and less than 10% reported photic phenomena. The IOL showed an excellent rotational stability.
CONCLUSIONS: The enhanced depth of focus IOL with 1.5 D of near add showed excellent intermediate and far visual performance and acceptable near visual restoration. Patient satisfaction was very high, and few patients reported disturbing photic phenomena.
Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28602323     DOI: 10.1016/j.jcrs.2017.01.024

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Temporary changes of visual outcomes and anterior chamber parameters after phacoemulsification and low-add-power segmented intraocular lens implantation for primary angle closure disease.

Authors:  Yohei Chikaraishi; Yoshikuni Arakaki; Hideki Koizumi
Journal:  Int Ophthalmol       Date:  2021-03-22       Impact factor: 2.031

2.  One-year clinical evaluation of rotationally asymmetric multifocal intraocular lens with +1.5 diopters near addition.

Authors:  Tetsuro Oshika; Hiroyuki Arai; Yoshifumi Fujita; Mikio Inamura; Yasushi Inoue; Toru Noda; Kazunori Miyata
Journal:  Sci Rep       Date:  2019-09-11       Impact factor: 4.379

3.  Visual Performance and Optical Quality after Implantation of a New Generation Monofocal Intraocular Lens.

Authors:  Kyoung Hae Kang; Mi Yeon Song; Kook Young Kim; Kyu-Yeon Hwang; Young-A Kwon; Kyungmin Koh
Journal:  Korean J Ophthalmol       Date:  2021-04-05

4.  Prospective assessment of plate-haptic rotationally asymmetric multifocal toric intraocular lens with near addition of + 1.5 diopters.

Authors:  Tetsuro Oshika; Kazuno Negishi; Toru Noda; Hiroyuki Arai; Mikio Inamura; Yasushi Inoue; Teruyuki Miyoshi; Yoshifumi Fujita; Kazunori Miyata; Yumi Hasegawa
Journal:  BMC Ophthalmol       Date:  2020-11-18       Impact factor: 2.209

5.  Polychromatic Assessment of a Refractive Segmented EDOF Intraocular Lens.

Authors:  Scott García; Luís Salvá; Salvador García-Delpech; Anabel Martínez-Espert; Vicente Ferrando; Diego Montagud-Martínez
Journal:  J Clin Med       Date:  2022-03-08       Impact factor: 4.241

  5 in total