Literature DB >> 28602320

Precision pulse capsulotomy: Initial clinical experience in simple and challenging cataract surgery cases.

Kevin Waltz1, Vance M Thompson2, Gabriel Quesada2.   

Abstract

PURPOSE: To evaluate precision pulse capsulotomy (PPC) in simple and challenging cataract surgery cases.
SETTING: Clínica Quesada, San Salvador, El Salvador.
DESIGN: Prospective case series.
METHODS: This single-center prospective study assessed cataract surgeries with anterior capsulotomy performed using a PPC device through a 2.2 mm corneal incision in the presence of an ophthalmic viscosurgical device. This was followed by phacoemulsification and intraocular lens implantation. Outcomes included capsulotomy appearance and diameter, surgical complications, and postoperative visual acuity.
RESULTS: The study comprised 38 eyes. All cases resulted in 360-degree complete, round capsulotomies averaging 5.5 mm in diameter with intracapsular IOL fixation. No PPC-related complications were observed intraoperatively or on follow-up at 3 to 8 months. The PPC was useful in challenging cases with corneal opacities that obscured the capsulotomy path or with poorly dilated pupils. Precision pulse capsulotomy occurs instantaneously everywhere along the capsulotomy path, which allowed safe release of subcapsular pressure in intumescent cataracts with consistent creation of a round, appropriately sized capsulotomy. The PPC edge quality was shown in a case with 6 clock hours of zonular dialysis in which iris hooks held the capsulotomy edge for over 45 minutes for removal of a 4+ cataract.
CONCLUSIONS: Precision pulse capsulotomy had a short learning curve and was integrated seamlessly into the surgical routine. The combination of suction with ultrafast capsulotomy provided capsulotomy roundness, sizing, safety, and edge quality that significantly facilitated difficult cases. The ease of use, consistency, and efficiency of PPC capsulotomy might support its use under many practice scenarios.
Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28602320     DOI: 10.1016/j.jcrs.2017.01.023

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  11 in total

1.  Zepto precision pulse capsulotomy: A new automated and disposable capsulotomy technology.

Authors:  David F Chang
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

Review 2.  Managing the posterior polar cataract: An update.

Authors:  Abhay R Vasavada; Vaishali A Vasavada
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

3.  Commentary: Precision pulse capsulotomy: New technology for capsulorhexis.

Authors:  Lakshey Dudeja
Journal:  Indian J Ophthalmol       Date:  2018-09       Impact factor: 1.848

4.  Precision pulse capsulotomy in phacoemulsification: Clinical experience in Indian eyes.

Authors:  Jai A Kelkar; Hetal M Mehta; Aditya S Kelkar; Aanchal A Agarwal; Akshay A Kothari; Shreekant B Kelkar
Journal:  Indian J Ophthalmol       Date:  2018-09       Impact factor: 1.848

5.  Precision pulse capsulotomy: an automated alternative to manual capsulorhexis in paediatric cataract.

Authors:  Pratik Chougule; Vivekanand Warkad; Akshay Badakere; Ramesh Kekunnaya
Journal:  BMJ Open Ophthalmol       Date:  2019-05-31

Review 6.  Techniques of anterior capsulotomy in cataract surgery.

Authors:  Bhavana Sharma; Robin G Abell; Tarun Arora; Tom Antony; Rasik B Vajpayee
Journal:  Indian J Ophthalmol       Date:  2019-04       Impact factor: 1.848

7.  Precision pulse capsulotomy in challenging cataract surgery cases.

Authors:  Min Ji Park; Chan Woo Bang; Sang Youp Han
Journal:  Clin Ophthalmol       Date:  2019-07-25

8.  Comparison of postoperative axial stability of intraocular lens and capsulotomy parameters between precision pulse capsulotomy and continuous curvilinear capsulotomy: A prospective cohort study.

Authors:  Seung Pil Bang; Jong Hwa Jun
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

9.  Clinical Results After Precision Pulse Capsulotomy.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2020-12-29

10.  Zepto-rhexis: A new surgical technique of capsulorhexis using precision nano-pulse technology in difficult cataract cases.

Authors:  Suresh K Pandey; Vidushi Sharma
Journal:  Indian J Ophthalmol       Date:  2018-08       Impact factor: 1.848

View more