Literature DB >> 28599154

The importance of the relationship between mechanical analyses and rheometry of mucoadhesive thermoresponsive polymeric materials for biomedical applications.

Sabrina Barbosa De Souza Ferreira1, Jéssica Bassi Da Silva1, Mariana Volpato Junqueira1, Fernanda Belincanta Borghi-Pangoni1, Raquel Guttierres Gomes2, Marcos Luciano Bruschi3.   

Abstract

Pluronic F127® was associated with a carbomer homopolymer type B, as a model polymer blend to evidence the information provided by rheological and mechanical analyses on the development of bioadhesive thermoresponsive systems. The mechanical analysis enabled to observe that 20% (w/w) Pluronic F127®-polymer blends were harder, more adhesive, more mucoadhesive, more compressive and less soft. In addition, continuous flow rheometry demonstrated that the systems were plastic with rheopexy (15%, w/w, Pluronic F127®) or thixotropic (20%, w/w, Pluronic F127®). Oscillatory rheometry exhibited the increase of temperature, and the polymeric concentration increases the elasticity of the formulations. Moreover, correlation index showed that softness and textural analysis can be correlated and complementary, whereas adhesiveness cannot be correlated to mucoadhesion and is less specific. Rheological interaction parameter and gelation temperature showed that 15/0.25-polymer blend is suitable for pharmaceutical and biomedical application, since it can be administered in the liquid form and be gelled in the application site with proper mucoadhesion that can suggest an improved clinical efficacy. Therefore, the mechanical and rheological analyses are useful to characterize and select the best bioadhesive thermoresponsive formulation for the proposed treatment with improved performance.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Carbomer; Mucoadhesion; Pluronic F127; Rheology; Softness index; Texture profile analysis

Mesh:

Substances:

Year:  2017        PMID: 28599154     DOI: 10.1016/j.jmbbm.2017.05.040

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

1.  Design of a nanostructured mucoadhesive system containing curcumin for buccal application: from physicochemical to biological aspects.

Authors:  Sabrina Barbosa de Souza Ferreira; Gustavo Braga; Évelin Lemos Oliveira; Jéssica Bassi da Silva; Hélen Cássia Rosseto; Lidiane Vizioli de Castro Hoshino; Mauro Luciano Baesso; Wilker Caetano; Craig Murdoch; Helen Elizabeth Colley; Marcos Luciano Bruschi
Journal:  Beilstein J Nanotechnol       Date:  2019-11-25       Impact factor: 3.649

2.  Optimization of the Micellar-Based In Situ Gelling Systems Posaconazole with Quality by Design (QbD) Approach and Characterization by In Vitro Studies.

Authors:  Meltem Ezgi Durgun; Burcu Mesut; Mayram Hacıoğlu; Sevgi Güngör; Yıldız Özsoy
Journal:  Pharmaceutics       Date:  2022-02-27       Impact factor: 6.321

  2 in total