Literature DB >> 28589458

The applicability of a large-volume injection (LVI) system for quantitative analysis of permanent gases O2 and N2 using a gas chromatograph/barrier discharge ionization detector.

Sang-Hee Jo1, Ki-Hyun Kim2.   

Abstract

To develop accurate quantitation methods for two major permanent gases, N2 and O2, a series of calibration experiments were carried out using a gas chromatograph (GC)/barrier discharge ionization detector (BID) equipped with a large-volume injection (LVI) system. To this end, gaseous working standards (WSs) diluted with helium gas were prepared at ten different concentration levels representing three different concentration ranges (in ppm) in 1-L polyester aluminum (PEA) bags ((1) low, 209~2090 (O2) and 791~7910 (N2); (2) moderate, 2090 ~ 20,900 (O2) and 7910~79,100 (N2); and (3) high, 20,900~209,000 (O2) and 79,100~791,000 (N2)). Cross-calibration experiments for each individual WS were carried out using the loop injection system with four different capacities (0.01, 0.5, 1, and 10 mL). The calibration results were then evaluated with respect to key variables including loop capacity, concentration, and mass quantity. Accordingly, we observed the optimal performance of the BID in terms of sensitivity and linearity (R 2 > 0.98) when the WS of the moderate concentration range was analyzed with the small loop (0.01 and 0.5 mL). The method detection limit (MDL) values of the four loop sizes (between 0.01 and 10 mL) were 7~500 ng for O2 (38.4~557 ppm) and 24~2230 ng for N2 (195~2105 ppm).

Entities:  

Keywords:  Barrier discharge ionization detector; Calibration; Large-volume injection system; Permanent gas; Polyester aluminum bag

Mesh:

Substances:

Year:  2017        PMID: 28589458     DOI: 10.1007/s10661-017-6024-1

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  11 in total

1.  Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath.

Authors:  Mark T Roberge; John W Finley; Henry C Lukaski; Anthony J Borgerding
Journal:  J Chromatogr A       Date:  2004-02-20       Impact factor: 4.759

2.  Gas chromatographic applications with the dielectric barrier discharge detector.

Authors:  Ronda Gras; Jim Luong; Matthew Monagle; Bill Winniford
Journal:  J Chromatogr Sci       Date:  2006-02       Impact factor: 1.618

3.  Analysis of part-per-billion level of arsine and phosphine in light hydrocarbons by capillary flow technology and dielectric barrier discharge detector.

Authors:  R Gras; J Luong; M Hawryluk; M Monagle
Journal:  J Chromatogr A       Date:  2009-11-18       Impact factor: 4.759

4.  Water determination in active pharmaceutical ingredients using ionic liquid headspace gas chromatography and two different detection protocols.

Authors:  Lillian A Frink; Choyce A Weatherly; Daniel W Armstrong
Journal:  J Pharm Biomed Anal       Date:  2014-01-31       Impact factor: 3.935

5.  Pulsed discharge helium ionization detector with multiple combined bias/collecting electrodes for gas chromatography.

Authors:  Huamin Cai; Stanley D Stearns
Journal:  J Chromatogr A       Date:  2013-02-01       Impact factor: 4.759

6.  Rapid analysis of ethanol and water in commercial products using ionic liquid capillary gas chromatography with thermal conductivity detection and/or barrier discharge ionization detection.

Authors:  Choyce A Weatherly; Ross M Woods; Daniel W Armstrong
Journal:  J Agric Food Chem       Date:  2014-02-17       Impact factor: 5.279

7.  Validation of an analytical method for simultaneous high-precision measurements of greenhouse gas emissions from wastewater treatment plants using a gas chromatography-barrier discharge detector system.

Authors:  Raffaella Pascale; Marianna Caivano; Alessandro Buchicchio; Ignazio M Mancini; Giuliana Bianco; Donatella Caniani
Journal:  J Chromatogr A       Date:  2016-11-18       Impact factor: 4.759

8.  Effect of the chloride ion as a hole scavenger on the photocatalytic conversion of CO2 in an aqueous solution over Ni-Al layered double hydroxides.

Authors:  Shoji Iguchi; Kentaro Teramura; Saburo Hosokawa; Tsunehiro Tanaka
Journal:  Phys Chem Chem Phys       Date:  2015-07-21       Impact factor: 3.676

9.  Multidimensional gas chromatography for the characterization of permanent gases and light hydrocarbons in catalytic cracking process.

Authors:  J Luong; R Gras; H J Cortes; R A Shellie
Journal:  J Chromatogr A       Date:  2012-11-19       Impact factor: 4.759

10.  Effects of injection volume change on gas chromatographic sensitivity determined with two contrasting calibration approaches for volatile organic compounds.

Authors:  Ki-Hyun Kim; Hang Thi Nguyen
Journal:  J Sep Sci       Date:  2007-02       Impact factor: 3.645