Literature DB >> 28588418

Biological imaging using light-addressable potentiometric sensors and scanning photo-induced impedance microscopy.

Fan Wu1, Inmaculada Campos1,2, De-Wen Zhang1,3, Steffi Krause1.   

Abstract

Light-addressable potentiometric sensors (LAPS) and scanning photo-induced impedance microscopy (SPIM) use photocurrent measurements at electrolyte-insulator-semiconductor substrates for spatio-temporal imaging of electrical potentials and impedance. The techniques have been used for the interrogation of sensor arrays and the imaging of biological systems. Sensor applications range from the detection of different types of ions and the label-free detection of charged molecules such as DNA and proteins to enzyme-based biosensors. Imaging applications include the temporal imaging of extracellular potentials and dynamic concentration changes in microfluidic channels and the lateral imaging of cell surface charges and cell metabolism. This paper will investigate the current state of the art of the measurement technology with a focus on spatial and temporal resolution and review the biological applications, these techniques have been used for. An outlook on future developments in the field will be given.

Keywords:  biosensors; electrochemical imaging; impedance; ion concentrations; potentiometric sensor

Year:  2017        PMID: 28588418      PMCID: PMC5454363          DOI: 10.1098/rspa.2017.0130

Source DB:  PubMed          Journal:  Proc Math Phys Eng Sci        ISSN: 1364-5021            Impact factor:   2.704


  43 in total

1.  Rapid identification of biological warfare agents using an instrument employing a light addressable potentiometric sensor and a flow-through immunofiltration-enzyme assay system.

Authors:  K A Uithoven; J C Schmidt; M E Ballman
Journal:  Biosens Bioelectron       Date:  2000-01       Impact factor: 10.618

2.  Spatially resolved monitoring of cellular metabolic activity with a semiconductor-based biosensor.

Authors:  B Stein; M George; H E Gaub; J C Behrends; W J Parak
Journal:  Biosens Bioelectron       Date:  2003-01       Impact factor: 10.618

3.  Cell-based biosensors based on light-addressable potentiometric sensors for single cell monitoring.

Authors:  Gaixia Xu; Xuesong Ye; Lifeng Qin; Ying Xu; Yan Li; Rong Li; Ping Wang
Journal:  Biosens Bioelectron       Date:  2005-03-15       Impact factor: 10.618

4.  Determination of dissociation constant and concentration of an anti-DNA antibody by using the light-addressable potentiometric sensor.

Authors:  K Dill; C Fraser; J A Blomdahl; J D Olson
Journal:  J Biochem Biophys Methods       Date:  1996-01-11

5.  An integrated label-free cell-based biosensor for simultaneously monitoring of cellular physiology multiparameter in vitro.

Authors:  Ning Hu; Jie Zhou; Kaiqi Su; Diming Zhang; Lidan Xiao; Tianxing Wang; Ping Wang
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

6.  Label-free functional assays of chemical receptors using a bioengineered cell-based biosensor with localized extracellular acidification measurement.

Authors:  Liping Du; Ling Zou; Luhang Zhao; Liquan Huang; Ping Wang; Chunsheng Wu
Journal:  Biosens Bioelectron       Date:  2013-11-23       Impact factor: 10.618

7.  Olfactory cell-based biosensor: a first step towards a neurochip of bioelectronic nose.

Authors:  Qingjun Liu; Hua Cai; Ying Xu; Yan Li; Rong Li; Ping Wang
Journal:  Biosens Bioelectron       Date:  2006-03-29       Impact factor: 10.618

8.  Rapid immunofiltration assay of Newcastle disease virus using a silicon sensor.

Authors:  W E Lee; H G Thompson; J G Hall; R E Fulton; J P Wong
Journal:  J Immunol Methods       Date:  1993-11-05       Impact factor: 2.303

9.  Unlabeled multi tumor marker detection system based on bioinitiated light addressable potentiometric sensor.

Authors:  Yun-Fang Jia; Chun-Ying Gao; Jia He; Dao-Fu Feng; Ke-Li Xing; Ming Wu; Yang Liu; Wen-Sheng Cai; Xi-Zeng Feng
Journal:  Analyst       Date:  2012-07-05       Impact factor: 4.616

10.  Influences of Probe's Morphology for Metal Ion Detection Based on Light-Addressable Potentiometric Sensors.

Authors:  Chen Shao; Shuang Zhou; Xuebo Yin; Yajun Gu; Yunfang Jia
Journal:  Sensors (Basel)       Date:  2016-05-14       Impact factor: 3.576

View more
  3 in total

Review 1.  Recent Developments of High-Resolution Chemical Imaging Systems Based on Light-Addressable Potentiometric Sensors (LAPSs).

Authors:  Tao Liang; Yong Qiu; Ying Gan; Jiadi Sun; Shuqi Zhou; Hao Wan; Ping Wang
Journal:  Sensors (Basel)       Date:  2019-10-03       Impact factor: 3.576

2.  InGaN as a Substrate for AC Photoelectrochemical Imaging.

Authors:  Bo Zhou; Anirban Das; Menno J Kappers; Rachel A Oliver; Colin J Humphreys; Steffi Krause
Journal:  Sensors (Basel)       Date:  2019-10-11       Impact factor: 3.576

3.  High Spatial Resolution Ion Imaging by Focused Electron-Beam Excitation with Nanometric Thin Sensor Substrate.

Authors:  Kiyohisa Nii; Wataru Inami; Yoshimasa Kawata
Journal:  Sensors (Basel)       Date:  2022-02-01       Impact factor: 3.576