Effect of dry eye on Scheimpflug imaging of the cornea and elevation data.

Leyla Asena1, Dilek D Altınörs2, Şefik Cezairlioğlu2, Sefer Ogün Bölük3.   

Abstract

OBJECTIVE: To evaluate the effect of dry eye on Scheimpflug imaging of the cornea and elevation data.
DESIGN: Prospective observational study. PARTICIPANTS: Scheimpflug images of 50 patients with dry eye who were being tested for eligibility for corneal refractive surgery were screened. Twelve eyes of 12 patients with abnormal Belin/Ambrosio enhanced ectasia display (BAD) anterior elevation difference were included in the study. The patients had no history of contact lens wear or any other sign of ectasia.
METHODS: Peak central corneal densitometry value, corneal volume, pachymetry at the thinnest point, and BAD anterior elevation difference value at the centre of the 9 mm zone were recorded before and after 4 weeks of dry eye treatment. Measurements were compared with the Wilcoxon signed rank test.
RESULTS: The mean corneal peak densitometry and volume were similar before and after therapy (p = 0.465 and p = 0.441, respectively). The mean anterior elevation difference value at the centre of the 9 mm zone before treatment (6.67 ± 1.72 µm) was significantly higher than the mean post-treatment value (4.00 ± 1.48 µm) (p = 0.002). The mean pachymetry at the thinnest location after treatment (548 ± 11.0) was significantly higher than the pretreatment value (538 ± 8.5) (p = 0.027).
CONCLUSIONS: BAD anterior elevation differences and pachymetric measurements may be affected by ocular surface or tear film abnormalities associated with dry eye disease. Repeated evaluations after treatment may reveal normal results.
Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28576215     DOI: 10.1016/j.jcjo.2016.11.005

Source DB:  PubMed          Journal:  Can J Ophthalmol        ISSN: 0008-4182            Impact factor:   1.882


  5 in total

1.  The Effect of ChromaGen Contact Lenses on Corneal Clarity: A Corneal Densitometry.

Authors:  Cagri Ilhan; Mehmet Ali Sekeroglu; Sibel Doguizi; Pelin Yilmazbas
Journal:  Beyoglu Eye J       Date:  2022-05-27

2.  Potential Risks of Corneal Refractive Surgery in Patients with Ectodermal Dysplasia.

Authors:  Majid Moshirfar; Duncan J Williams; Yasmyne C Ronquillo; Briana K Ply
Journal:  Ophthalmol Ther       Date:  2022-05-09

3.  Impact of tear optics on the repeatability of Pentacam AXL wave and iTrace in measuring anterior segment parameters and aberrations.

Authors:  Gairik Kundu; Rohit Shetty; Pooja Khamar; Sneha Gupta; Ritika Mullick; Vaitheeswaran L Ganesan; Sharon D'Souza
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

4.  Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

Authors:  Aysun Şanal Doğan; Canan Gürdal; Mehmet Talay Köylü
Journal:  Turk J Ophthalmol       Date:  2018-04-25

5.  Comparison of corneal thickness in patients with dry eye disease using the Pentacam rotating Scheimpflug camera and anterior segment optical coherence tomography.

Authors:  Keiichi Fujimoto; Takenori Inomata; Yuichi Okumura; Nanami Iwata; Kenta Fujio; Atsuko Eguchi; Ken Nagino; Hurramhon Shokirova; Maria Karasawa; Akira Murakami
Journal:  PLoS One       Date:  2020-02-03       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.