Literature DB >> 28574351

Fabrication and Characterization of a 20-MHz Microlinear Phased-Array Transducer for Intervention Guidance.

Chi Tat Chiu, Bong Jin Kang, Payam Eliahoo, Theodore Abraham, K Kirk Shung.   

Abstract

This paper describes the design and fabrication of a miniature ultrasonic phased-array transducer used for intervention guidance. Currently, ultrasound probes are often placed at the body surface of the patients, leading to several drawbacks including the limitation of penetration and image quality. In order to improve the reliability of the guiding process, we propose a miniature phased-array transducer that can be placed adjacent to the intervention device during the interventional procedure. In this paper, we report the work that has been carried out on the development of this miniature phased-array transducer. It comprised 48 elements housed in a 3-mm-diameter needle. A specially designed flexible circuit was used for accommodating the transducer array in the long, thin needle housing. The center frequency and the fractional bandwidth were approximately 20 MHz and 42%, respectively, with an average crosstalk lower than -30 dB. The axial and azimuth resolutions were approximately 80 and [Formula: see text], respectively. The imaging capability of the transducer was further evaluated by acquiring the B-mode images of a needle in a cow liver. The performance of the proposed phased-array transducer demonstrates the feasibility of such an approach for interventional guidance.

Entities:  

Mesh:

Year:  2017        PMID: 28574351      PMCID: PMC5600483          DOI: 10.1109/TUFFC.2017.2709623

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  MRI-guided biopsy of the prostate increases diagnostic performance in men with elevated or increasing PSA levels after previous negative TRUS biopsies.

Authors:  Aristotelis G Anastasiadis; Matthias P Lichy; Udo Nagele; Markus A Kuczyk; Axel S Merseburger; Joerg Hennenlotter; Stefan Corvin; Karl-Dietrich Sievert; Claus D Claussen; Arnulf Stenzl; Heinz-Peter Schlemmer
Journal:  Eur Urol       Date:  2006-03-24       Impact factor: 20.096

2.  Real-time MRI at a resolution of 20 ms.

Authors:  Martin Uecker; Shuo Zhang; Dirk Voit; Alexander Karaus; Klaus-Dietmar Merboldt; Jens Frahm
Journal:  NMR Biomed       Date:  2010-10       Impact factor: 4.044

3.  Free-hand, ultrasound-guided percutaneous renal biopsy: experience from a single operator.

Authors:  Sydney Tang; Jimmy H C Li; Sing Leung Lui; Tak Mao Chan; Ignatius Kum Po Cheng; Kar Neng Lai
Journal:  Eur J Radiol       Date:  2002-01       Impact factor: 3.528

Review 4.  CT-guided biopsy of bone: a radiologist's perspective.

Authors:  Leandro A Espinosa; David A Jamadar; Jon A Jacobson; Michel O DeMaeseneer; Farhad S Ebrahim; Brian J Sabb; Matthew T Kretschmer; Janet S Biermann; Sung-Moon Kim
Journal:  AJR Am J Roentgenol       Date:  2008-05       Impact factor: 3.959

5.  Guided versus blind liver biopsy for chronic hepatitis C: clinical benefits and costs.

Authors:  R J Farrell; P F Smiddy; R M Pilkington; A A Tobin; E E Mooney; I J Temperley; G S McDonald; H A Bowmer; G F Wilson; D Kelleher
Journal:  J Hepatol       Date:  1999-04       Impact factor: 25.083

Review 6.  Hepatic aspiration and biopsy techniques.

Authors:  S C Kerwin
Journal:  Vet Clin North Am Small Anim Pract       Date:  1995-03       Impact factor: 2.093

Review 7.  The role of sonography in the placement and management of jugular and subclavian central venous catheters.

Authors:  M L Skolnick
Journal:  AJR Am J Roentgenol       Date:  1994-08       Impact factor: 3.959

8.  A high-frequency annular-array transducer using an interdigital bonded 1-3 composite.

Authors:  Hamid Reza Chabok; Jonathan M Cannata; Hyung Ham Kim; Jay A Williams; Jinhyoung Park; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-01       Impact factor: 2.725

9.  Percutaneous echocardiographically guided pericardiocentesis in pediatric patients: evaluation of safety and efficacy.

Authors:  T S Tsang; E K El-Najdawi; J B Seward; D J Hagler; W K Freeman; P W O'Leary
Journal:  J Am Soc Echocardiogr       Date:  1998-11       Impact factor: 5.251

10.  CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions.

Authors:  Y Li; Y Du; H F Yang; J H Yu; X X Xu
Journal:  Clin Radiol       Date:  2012-11-22       Impact factor: 2.350

View more
  5 in total

1.  Co-Integrated PIN-PMN-PT 2-D Array and Transceiver Electronics by Direct Assembly Using a 3-D Printed Interposer Grid Frame.

Authors:  Robert Wodnicki; Haochen Kang; Ruimin Chen; Nestor E Cabrera-Munoz; Hayong Jung; Laiming Jiang; Josquin Foiret; Yu Liu; Victoria Chiu; Douglas N Stephens; Qifa Zhou; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-30       Impact factor: 2.725

2.  Laser Scanning Guided Localization Imaging with a Laser-Machined Two-Dimensional Flexible Ultrasonic Array.

Authors:  Jianzhong Chen; Wei Liu; Dianbao Gu; Dawei Wu
Journal:  Micromachines (Basel)       Date:  2022-05-10       Impact factor: 3.523

3.  Design, Fabrication, and Evaluation of Multifocal Point Transducer for High-Frequency Ultrasound Applications.

Authors:  Thanh Phuoc Nguyen; Nguyen Thanh Phong Truong; Nhat Quang Bui; Van Tu Nguyen; Giang Hoang; Jaeyeop Choi; Thi Tuong Vy Phan; Van Hiep Pham; Byung-Gak Kim; Junghwan Oh
Journal:  Sensors (Basel)       Date:  2019-02-01       Impact factor: 3.576

4.  PIN-PMN-PT Single Crystal 1-3 Composite-based 20 MHz Ultrasound Phased Array.

Authors:  Wei Zhou; Tao Zhang; Jun Ou-Yang; Xiaofei Yang; Dawei Wu; Benpeng Zhu
Journal:  Micromachines (Basel)       Date:  2020-05-21       Impact factor: 2.891

5.  Development of a 16-Channel Broadband Piezoelectric Micro Ultrasonic Transducer Array Probe for Pipeline Butt-Welded Defect Detection.

Authors:  Bolun Li; Changhe Sun; Shouchun Xin; Mingzhang Luo; Chuang Hei; Guofeng Du; Ankang Feng
Journal:  Sensors (Basel)       Date:  2022-09-21       Impact factor: 3.847

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.